KUSAM-MECO                                                                                April 2011

®

?

  

Overload Protections:

 

    ACA Clamp on jaws : AC 600 A rms continuous
    “+” & COM Terminals(all other functions):
         660VDC / VAC rms

?

  

Power Supply :

 1.5V AAA Size battery X 2

?

  

Power consumption :

 5.2mA typical

?

  

Low battery :

 Below approx. 2.4V

?

  

APO Timing :

 Idle for 34 minutes

?

  

APO Consumption :

 10µA typical

?

  

Dimension : 

190(L) X 63(W) X 32(H) mm

?

  

Weight :

 179gm

?

  

Accessories :

 Test leads(pair),User's Manual.

?

  

Optional Accessories

:    PC Interface,

     USB interface kit BRUA-13X.

?

  

E.M.C. :

 Meets EN61326-1:2006 (EN55022,

    EN61000-3-2, EN61000-3-3, EN61000-4-2,
    EN61000-4-3, EN61000-4-4, EN61000-4-5, 
    EN61000-4-6, EN61000-4-8, EN61000-4-11)
        In an RF field of 3V/m.
       Capacitance function is not specified
              Other function ranges : Total Accuracy = 
                            Specified Ac 100 digits
       Performance above 3V/m is not specified

7

KUSAM-MECO                                                                                April 2011

®

6) ELECTRICAL SPECIFICATIONS :

Accuracy is ± (% reading number of digits) 
or otherwise specified, at 23°C ± 5°C & less than 
75% relative humidity.

DC Voltage

Range

1)

voltage values.

Input impedance :

 10M

W

, 50pF nominal.

Added range to indicate instantaneous over-range

Resolution

Accuracy

6.000V

60.00V

±(0.5% rdg + 5 dgts)

600.0V

1)

600V

TM

AutoCheck  DCV

Range

Resolution

Accuracy

6.000V

60.00V

±(1.3% rdg + 5 dgts)

600.0V

1)

600V

1      mV

10    mV

100  mV

1         V

1      mV

10    mV

100  mV

1         V

1)

Added range to indicate instantaneous over-range 

  voltage values

TM

AutoCheck  Lo-Z DCV Threshold:

 

    >+1.0VDC & < -1.0VDC nominal

TM

AutoCheck  Lo-Z DCV Input Impedance:
    Initially approx. 2.5k

W

, 200pF nominal,

    Impedance increases abruptly within a fraction of a 
    second as display voltage is above 50V(typical).
    Ended up impedances vs display voltages 
    typically are:
   15k

W

 

            

@100V

   

100k

W

                       

@300V

   250k

W

                       

@600V

Содержание KM 181

Страница 1: ...Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Testers Solar Power Meter EMF Detector Wood Paper Grain...

Страница 2: ...ter becomes a low impedance circuit element Even if you correctly insert your clamp meter in to the circuit you can still damage your meter Don t try to measure current in excess of your meter s capac...

Страница 3: ...r IEC61010 1 2nd Ed EN61010 1 2nd Ed UL61010 1 2nd Ed CAN CSA C22 2 No 61010 1 0 92 IEC61010 2 032 EN61010 2 032 UL61010B 2 032 CAN CSA C22 2 No 61010 2 032 04 Measurement Category III 600V AC DC Per...

Страница 4: ...mine proper meter functioning Keep your hands fingers behind the hand finger barriers of the meter and the test leads that indicate the limits of safe access of the hand held part during measurement I...

Страница 5: ...6 digits 6000 counts 3 1 2 digits 1 999 counts for Hz Polarity Automatic Update Rate 5 per second nominal Operating Temperature 0 C to 40 C Pollution degree 2 Altitude Operating below 2000m Relative...

Страница 6: ...y 100 digits Performance above 3V m is not specified 7 KUSAM MECO April 2011 6 ELECTRICAL SPECIFICATIONS Accuracy is reading digits number of digits or otherwise specified at 23 C 5 C less than 75 rel...

Страница 7: ...00W 32ms approx Audible Threshold Response Time 9 KUSAM MECO April 2011 AutoCheck_ACV with Low Pass Filter Range Resolution Accuracy1 6 000V 60 00V 3 0 rdg 80 dgts 600 0V 2 600V 1 mV 10 mV 100 mV 1 V...

Страница 8: ...Add 12d to specified accuracy while reading is at 1 to 10 of range 2 Induced error from adjacent current carrying conductor 0 5A A 3 Specified accuracy is from 1 to 100 of range and for measurements m...

Страница 9: ...s for non invasive current measurements Hz ACA function 12 KUSAM MECO April 2011 7 PRODUCT DESCRIPTION CREST C HOLD H EF REL PC Comm VFD RANGE Hz Hz VFD Auto VW 0 000V 1 2 3 3 4 5 7 8 9 10 6 1 Transfo...

Страница 10: ...asurement Locate the conductor s at the Jaws center as much as possible to get the best measuring accuracy For removal press the jaw trigger and remove the jaws from the conductor s CAUTION Applicatio...

Страница 11: ...heck mode an unexpected display of voltage readings alerts you that the object under test is being energized 17 KUSAM MECO April 2011 Ghost Voltage Buster Gost Voltages are unwanted stray signals coup...

Страница 12: ...VW 2 008k W CREST C HOLD H EF REL PC Comm VFD RANGE Hz Hz VFD Auto VW 1 2W 00 18 KUSAM MECO April 2011 CREST C HOLD H EF REL PC Comm VFD RANGE Hz Hz VFD Auto VW Auto VW LoZ LoZ CREST C HOLD H EF REL...

Страница 13: ...in sequence Note Hz Hz Both ACV LoZ VFD ACV LoZ function selection are equipped with low pass filter to deal with VFD Variable Frequency Device Hz signals VFD ACV LoZ selection however further pre se...

Страница 14: ...f are disabled automatically in this mode Hold The hold feature freezes the display for later view Press the HOLD button momentarily to toggle the hold feature Relative Zero mode r Relative Zero mode...

Страница 15: ...ain meter accuracy If self diagnostic massage C_Er is being displayed while powering on some meter ranges might be largely out of specifications 24 KUSAM MECO April 2011 Manual or Auto ranging Note Ma...

Страница 16: ...01 REGISTERED QC PASS KUSAM MECO 26 KUSAM MECO April 2011 To avoid mis leading measurements stop using the meter and send it for re calibration Cleaning and Storage Periodically wipe the case with a d...

Страница 17: ...ed dealer shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO G 17 Bharat Industria...

Отзывы: