ELECTRICAL  SPECIFICATIONS : KM 088

o

o

Accuracy is ± (% of reading number of digits) or otherwise specified, at 23 C ± 5 C

Maximum Crest Factor <2.5:1 at full scale & <5:1 at half scale or otherwise specified, and with frequency spectrum not exceeding 

the specified frequency bandwidth for non-sinusoidal waveforms.

Range

TM

AMPTIP  CLAMP-ON AC CURRENT

1) 2) 3)

   Accuracy

     Resolution

40Hz ~ 100Hz

±(1.5%rdg + 5dgts)

0.01     A

60.00  A

100Hz ~ 400Hz

±(2.0%rdg + 5dgts)

0.01     A

60.00  A

1)

 

Induced error from adjacent current-carrying conductor :

 < 0.02A/A

2)

 Specified with Relative Zero 

D

 mode applied to offset the non-zero residual 

   readings, if any

3)

 Add 10d to the specified accuracy @ < 4A

Range

TM

AMPTIP  CLAMP-ON DC CURRENT

1) 2) 3)

   Accuracy

     Resolution

±(1.5%rdg + 5dgts)

0.01     A

60.00  A

1)

 

Induced error from adjacent current-carrying conductor :

 < 0.02A/A

2)

 Specified with DC-Zero mode applied to offset the non-zero residual readings, 

   if any

3)

 Add 10d to the specified accuracy @ < 4A

Range

TM

AMPTIP  CLAMP-ON DC + AC CURRENT

1) 2) 3)

   Accuracy

     Resolution

DC, 40Hz ~ 100Hz

±(2.0%rdg + 7dgts)

0.01     A

60.00  A

100Hz ~ 400Hz

±(2.2%rdg + 7dgts)

0.01     A

60.00  A

1)

 

Induced error from adjacent current-carrying conductor :

 < 0.08A/A

2)

 Specified with DC-Zero mode applied to offset the non-zero residual readings, 

   if any

3)

 Add 10d to the specified accuracy @ < 4A

All Specifications are subject to change without prior notice.

Chhaya com/D/chhaya/my documents/chhaya/backup/catlog/New catlog/2013-2014/KM 088.cdr

1)

 

Induced error from adjacent current-carrying conductor :

 < 0.02A/A

2)

 Add 10d to the specified accuracy @ < 9A

3)

 Maximum Crest Factor < 1.4 : 1 at full scale & < 2.8 : 1 at half scale

REGULAR CLAMP-ON AC CURRENT

Range

40Hz ~ 100Hz

2)

60.00  A

600.0  A

3)

1000   A

100Hz ~ 400Hz

2)

60.00  A

600.0  A

3)

1000   A

1) 2)

   Accuracy

±(1.8%rdg + 5dgts)

±(2.2%rdg + 5dgts)

     Resolution

0.01  A

0.1    A

1       A

0.01  A

0.1    A

1       A

1)

 

Induced error from adjacent current-carrying conductor :

 < 0.08A/A

2)

 Specified with DC-Zero mode applied to offset the non-zero residual readings, 

   if any

3)

 Add 10d to the specified accuracy @ < 9A

4)

 Maximum Crest Factor < 1.4 : 1 at full scale & < 2.8 : 1 at half scale

REGULAR CLAMP-ON DC + AC CURRENT

Range

DC, 40Hz ~ 100Hz

3)

60.00  A

600.0  A

4)

1000   A

100Hz ~ 400Hz

3)

60.00  A

600.0  A

4)

1000   A

1) 2)

   Accuracy

±(2.2%rdg + 7dgts)

±(2.5%rdg + 7dgts)

     Resolution

0.01  A

0.1    A

1       A

0.01  A

0.1    A

1       A

1)

 

Induced error from adjacent current-carrying conductor :

 < 0.02A/A 

2)

 Specified with DC-Zero mode applied to offset the non-zero residual readings, 

   if any

3)

 Add 10d to the specified accuracy @ < 9A

Range

REGULAR CLAMP-ON DC CURRENT

3)

60.00  A

1) 2)

   Accuracy

±(1.8%rdg + 5dgts)

600.0  A

1000   A

     Resolution

0.01  A

0.1    A

1       A

Range

AC VOLTAGE (with Digital Low-Pass Filter)

   Accuracy

     Resolution

Input Impedance :

 10M

W

, 100pF nominal

50Hz ~ 60Hz

±(0.8%rdg + 5dgts)

0.1     V

600.0  V

1         V

1000   V

20Hz ~ 200Hz

±(1.5%rdg + 5dgts)

0.1     V

600.0  V

1         V

1000   V

200Hz ~ 400Hz

±(10%rdg + 5dgts)

0.1     V

600.0  V

1         V

1000   V

Range

DC + AC VOLTAGE (with Digital Low-pass Filter)

   Accuracy

     Resolution

Input Impedance :

 10M

W

, 100pF nominal

50Hz ~ 60Hz

±(1.0%rdg + 7dgts)

0.1     V

600.0  V

1        V

1000   V

DC, 40Hz ~ 200Hz

±(1.8%rdg + 7dgts)

0.1     V

600.0  V

1        V

1000   V

200Hz ~ 400Hz

±(12%rdg + 7dgts)

0.1     V

600.0  V

1        V

1000   V

600.0  V

1000   V

±(0.8%rdg + 5dgts)

DC VOLTAGE

Accuracy

Resolution

Range

0.1     V

1        V