Nearly every electrical engineer has a hand held digital clamp meter 

(Tongtester). We sometimes take them for granted, until we damage them 

or “burn them out”. If you incorrectly connect your clamp meter to a circuit, 

or if you have the clamp meter on wrong setting, you damage the meter 

and  possibly  hurt  yourself.  You  can  also  get  into  trouble  if  you  try  to 

measure the voltage across a charged capacitor.

Clamp meter users frequently burn their meters by trying to measure 

current the same way as they measure voltage. Remember, you measure 

voltage across a circuit, and current through a circuit. When you use the 

current input, your clamp meter becomes a low impedance circuit element.

Even if you correctly insert your clamp meter in to the circuit, you can 

still damage your meter. Don’t try to measure current in excess of your 

meter’s capacity. Check the current capacity of the Clamp meter.

If  you  are  measuring  current  in  industrial  environment  to  prevent 

excess current from flowing through your meter, always disconnect your 

test leads from the circuit under test whenever you change Clamp meter 

functions.  Set  your  meter  to  the  correct  function,  say  current,  and  its 

highest range for the setting. If the reading is small, change the range to 

the next lower range till the reading can be read with the best possible 

accuracy. When measuring voltage, connect the test leads before your 

apply power to your circuit. To be safe, start by setting your meter to its 

highest range first.

TAKE  MEASUREMENT  CAREFULLY  AND  YOU’LL  SPARE  YOUR 
METER  AND  YOURSELF,  SOME  PAIN

Safety .......................................................................................01

Terms in this Manual ................................................................02

Electrical Symbols ...................................................................03

General Specifications .............................................................04

Electrical  Specifications ..........................................................06

Product Discription ...................................................................10

Operation ..................................................................................11

Maintenance ............................................................................ 17

Cleaning & Storage ..................................................................18

Battery Replacement ...............................................................18

Test Certificate .........................................................................19

Warranty ..................................................................................20

Содержание KM 061

Страница 1: ...Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Tester...

Страница 2: ...e current in excess of your meter s capacity Check the current capacity of the Clamp meter If you are measuring current in industrial environment to prevent excess current from flowing through your me...

Страница 3: ...sers is double insulation per IEC61010 1 2nd Ed EN61010 1 2nd Ed UL61010 1 2nd Ed CAN CSA C22 2 No 61010 1 2nd Ed IEC61010 2 032 EN61010 2 032 UL61010B 2 032 CAN CSA C22 2 N0 61010 2 032 04 Category C...

Страница 4: ...M 061 True RMS sensing KM 062 Safety Meets IEC61010 1 2nd Ed EN61010 1 2nd Ed UL61010 1 2nd Ed CAN CSA C22 2 No 61010 1 0 92 IEC61010 2 032 EN61010 2 032 UL61010B 2 032 CAN CSA C22 2 No 61010 2 032 04...

Страница 5: ...10m A KM 061 190m A KM062 Dimension 188 L x 63 W x 40 H mm Weight 218gm approx Jaw opening Conductor diameter 30mm max Accessories Test lead pair batteries installed User s Manual Carrying case 6 DC...

Страница 6: ...Accuracy decreases gradually to 12 at low battery warning voltage of approx 2 4V 100 mW 1 W 10 W 100 W 1 KW 10 KW 100 pF 1 nF 10 nF 100 nF 1 m F 8 DCA Current Clamp on Range Resolution 1 2 Accuracy 40...

Страница 7: ...urrent magnetic field pick up 2 Hand Finger Barrier to indicate the limits of safe access of the meter during measurement 3 Push buttons for special functions features 4 Input jack for all functions E...

Страница 8: ...by the selected function range from where the Hz function is activated In ACV function activating the Hz function during significant measurements can get the most appropriate trigger level to avoid e...

Страница 9: ...he jaw mark indicates current flow direction on DCA positive readings For removal press the jaw trigger and remove the jaws from the conductor s Inputs are made through the clamp jaws for non invasive...

Страница 10: ...ed maximum value as fast as 30ms with auto ranging capability It allows the meter to capture INRUSH currents in current functions Press and hold the MAX button for 1 second or more to toggle to the ma...

Страница 11: ...tandard 1 5V AAA size battery x 2 or 1 5V AAA size Alkaline battery x 2 Loosen the 2 captive screws from the battery cover case Lift the battery cover case Replace the batteries Replace battery cover...

Страница 12: ...CO authorized dealer This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused alte...

Отзывы: