H

Symbol

No.

1

2

3

4

5

6

7

8

9

10

Meaning

Dangerous Voltages.

The battery is low.
     Warning : To avoid false readings, 
which could lead to possible electric 
shock or personal injury, replace the
battery as soon as the battery
indicator appears.

Indicator for AC voltage or current, 
The displayed value is the mean value.

Indicates negative reading.

Test of diode.

Data Hold is active.

The continuity buzzer is on.

A : Amperes (amps). The unit  of current.

V : Volts. The unit of voltage.

Hz : The unit of frequency. 

A

V

Hz

-   +

~

!

DISPLAY SYMBOLS

  

(see figure 2)

H

. . .

2

20

200

9

9

9

3

~

( Figure 2)

11

W

 : Ohm. The unit of resistance.

3

K

W

 : kilohm. 1 x 10  or 1000 ohms.

W

, k

W

12

°C : The unit of temperature.

°C

 

13

The unit of capacitance.

nF, 

µF

11

M

W

6

M

W

 : Megaohm :1x10  ohms.

MEASUREMENT OPERATION

n

Make sure the Low Battery display          is not 
on, otherwise false readings may be provided.

n

Pay extra attention to the       symbol which is 
located besides the input terminals of the Meter 
before carrying out measurement.

A. DC 

 

VOLTAGE MEASUREMENT

                                           (see figure 3)

  

Warning

To avoid harms to you or damages to the Meter 
from electric shock, please do not attempt to 
measure voltages higher than 1000V or 750V 
rms although readings may be obtained.

The DC Voltage ranges are :400mV, 4V, 40V, 400V, 
1000V. To measure DC voltage, connect the Meter 
as follows :
1) Insert the red test lead into the 

V

W

 

 input 

terminal and  the black test lead into the 

COM

 input 

terminal
2) Set the rotary switch to an appropriate 
measurement position in V        range.

3) Connect the test leads across with the object 
being measured.

The measured value is shown on the display.

- +

!

!

( Figure 3 )

Red

Black

~

V

W

CAP

NPN

PNP °C

m

A

mA

10A

CE

OFF

OFF

Hz

SELECT

RANGE

HOLD

Hz/DUTY

hFE

FUSED

10A/15SEC.

MAX

400mA

1000V MAX

V mA

W

COM

10A

207 MK-1(T)

399.9

E

E B C

~

~

~

~

!

!

12

Содержание 207-MK-1

Страница 1: ...ontact infrared Thermometer Thermo Hygrometer Thermo Anemometer Wood Moisture Meter Distance Meter Calibrators Gas Analysers Panel meters Battery Testers Digital Hand Held Temperature Indicators Digit...

Страница 2: ...vironment you can easily exceed those ratings The best way to avoid damage is to use a clamp meter or to connect a clamp attachment to your DMM To prevent excess current from flowing through your mete...

Страница 3: ...nging Digital Multimeter Model 207 MK1 T hereafter referred to as the Meter is a 3 digits Multimeter with steady operations and highly reliable hand held measuring instrument having different measurem...

Страница 4: ...1 A m Range 400 A m 4000 m A 40 mA 400 mA AC 2 5 rdg 5dgts 0 01 A 10 A 4 GENERAL SPECIFICATIONS Display 3 digit LCD Maximum reading 3999 with automatic sign and function annunciators Overrange Highes...

Страница 5: ...1 C Accuracy 0 1 rdg 4dgts Resolution 0 01 Hz Range 9 999 Hz FREQUENCY 0 001 MHz 9 999 MHz Overload Protection 250 V Rms Sensitivity 0 7V Rms 6 DC CURRENT Accuracy 1 2 rdg 2dgts AC 2 rgd 3dgts DC 1 5...

Страница 6: ...o the following rules n Before using the Meter inspect the case Do not use the Meter if it is damaged or the case or part of the case is removed Look for cracks or missing plastic Pay attention to the...

Страница 7: ...nal button operations 10 V W CAP NPN PNP C m A mA 10A CE OFF OFF Hz SELECT RANGE HOLD Hz DUTY hFE FUSED 10A 15SEC MAX 400mA 1000V MAX VW mA COM 10A 207 MK 1 T 399 9 E E B C The Multimeter Structure se...

Страница 8: ...display is not on otherwise false readings may be provided n Pay extra attention to the symbol which is located besides the input terminals of the Meter before carrying out measurement A DC VOLTAGE ME...

Страница 9: ...uit voltage between terminals and ground is greater than 60V DC or 30V rms If the fuse burns out during measurement the Meter may be damaged or the operator himself may be hurt 14 Caution n If the val...

Страница 10: ...ion and range for the measurement When the testing leads are connected to the current terminals do not parallel them across any circuit The AC current measurement has 5 measurement positions on the ro...

Страница 11: ...range for the measurement When the testing leads are connected to the current terminals do not parallel them across any circuit The DC current measurement has 5 measurement positions on the rotary sw...

Страница 12: ...10A 15SEC MAX 400mA 1000V MAX V mA W COM 10A 207 MK 1 T 399 9 E E B C Capacitor 20 Note n The test leads can add 0 1W to 0 3W of error to the Resistance measurement To obtain precision readings in lo...

Страница 13: ...DUTY hFE FUSED 10A 15SEC MAX 400mA 1000V MAX V mA W COM 10A 207 MK 1 T 399 9 E E B C 22 Caution n Never connect high voltage to the input sockets with the switch in Capacitance range n Using Capacitan...

Страница 14: ...value Figure 11 Red Black V W CAP NPN PNP C m A mA 10A CE OFF OFF Hz SELECT RANGE HOLD Hz DUTY hFE FUSED 10A 15SEC MAX 400mA 1000V MAX V mA W COM 10A 207 MK 1 T 399 9 E E B C 24 The frequency measure...

Страница 15: ...ads and the circuit under test Testing for Continuity To test for continuity connect the Meter as below 1 Insert the red test lead into VW terminal and the black test lead into the COM terminal 2 Set...

Страница 16: ...thorized dealer This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused altered n...

Отзывы: