![Kurth Electronic KE901 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/kurth-electronic/ke901/ke901_operating-manual_2011317007.webp)
© Kurth Electronic GmbH, All Rights Reserved
7
KE905 Remote
Solid, impact-resistant and waterproof
ABS casing
Battery compartment with captive screws
Four sockets for 3-pole TF connectors
Resistant Mylar front foil with short
operating information
2 special test cables for measurements
up to VDSL Annex Q
Insertion loss: 0 - 30 MHz < 0.5 dB
Crosstalk: -78 to -56 dB
Overvoltage protection up to 160 V AC / DC
1x 9 V battery, battery life approx. 200
hours at 450 mAh
Dimensions 160 x 95 x 35 mm
Weight with battery 290 g
KE910 Controller
Solid, impact-resistant and waterproof
ABS casing
Robust rubber keys
Battery compartment with captive screws
Short operating information on the back
side
Insulated test leads with banana plugs
Modified DTMF control signals
Gain Probe function min. 56 dB
Overvoltage protection up to 160 V AC / DC
1x 9 V battery, min. battery life 40 hours
at 450 mAh battery and use of speaker
< 10%
Dimensions 160 x 95 x 35 mm
Weight with battery 95 g
Port 1
Port 4
Port 2
Port 3
GND
Mode
On-Off
Port 1
Port 4
Port 2
Port 3
GND
Mode
On-Off
4 key
Port 1 is switched to port
2. Can also be used to re
-
connect the exchange line
to the customer after the
end of work.
Shift key + 4
Port 4 is connected
to port 2. This can be
used, for example, to
switch the exchange
line to another pair of
wires.
Port 1
Port 4
Port 2
Port 3
GND
Mode
On-Off
Port 1
Port 4
Port 2
Port 3
GND
Mode
On-Off
4 key
Port 1 is switched to port
3. This allows e.g. a level
transmitter connected to
port 3 to be switched to
the customer line on port
1, e.g. to measure the at
-
tenuation.
Shift key + 5
Port 4 connected to
port 3, port 1 open.
Technical data