Küppersbusch KD 674.1GE Скачать руководство пользователя страница 3

Part 1 - INSTALLATION INSTRUCTIONS

1  -  GENERAL  DATA

This hood has been designed to be wall-mounted above a cooking hob with one side
resting  against  a  wall.  It  works  either  by  suction  (external  outlet)  or  filter  (internal
recycling). 

Because of the complexity and weight of the hood, its installation

should  be  carried  out  by  qualified  staff,  taking  care  to  respect  all  local
regulations on air discharge. The manufacturer cannot be found liable for any
damage due to improper installation.

2  -  COMPONENTS

The cooker hood is made up of the following components (

fig. 1

):

2.1 - No. 1 canopy 

C

 complete

with  controls  and  worktop
illumination;

2.2 - No.  1  telescopic  chimney

stack 

A

  complete  with

ducting fan unit;

2.3 - No.  1  flange  Ø  120  or  Ø

150 

F

;

2.4 - No. 1 venting grill 

G

;

2.5 - No. 1 ducting spigot 

R

;

2.6 - No. 1 support rod 

B

;

2.7 - No. 1 fixing kit containing:

No. 1 wall bracket 

S

 to fix

the canopy hood;
No. 1 cover 

D

, screws, rawl

plugs and documentation.

3  -  SAFETY  WARNINGS

3.1  - When used in the extraction mode the cooker hood ducting must not be connected to

a flue which is used for exhausting fumes from appliances supplied with energy other
than  electric  such  as  a  central  heating  flue  or  water  heating  flue.

3.2  - Before connecting to the mains supply ensure that the mains voltage corresponds with

the  voltage  on  the  rating  plate  inside  the  hood.

3.3  - Connect the cooker hood to the mains via a double pole switch which has 3 mm metal

clearance  between  the  contacts.

3.4  - The  appliance  must  be  earthed.
3.5  - When installed, the hood must be positioned at least 65 cm above a cooking appliance.
3.6  - Never  do  flambé  cooking  under  this  cooker  hood.
3.7  - Never leave frying pans unattended during use as overheated fats and oils may catch

fire.

A08_01

R

G

F

S

B

A

C

1

1

Содержание KD 674.1GE

Страница 1: ...ageanweisungen Instructions for use and installation instructions Instructions d utilisation et avis de montage Gebruiksaanwijzing en montagehandleiding Istruzioni di uso e di montaggio Instrucciones de uso y de montaje KD 674 1GE KD 974 1GE ...

Страница 2: ...ENZIONE 13 3 1 Filtri antigrasso metallici 14 3 2 Filtro al carbone attivo 14 3 3 Illuminazione 15 3 4 Pulizia 15 1 GENERAL DATA 16 2 COMPONENTS 16 3 SAFETY WARNINGS 16 4 INSTALLATION 17 4 1 Selecting the type of installation 17 4 2 Installation of the hood canopy C 18 4 3 Installation of the chimney A 20 4 4 Ducting or recirculation fitting 22 4 5 Connection to power supply and checking of good w...

Страница 3: ...g spigot R 2 6 No 1 support rod B 2 7 No 1 fixing kit containing No 1 wall bracket S to fix the canopy hood No 1 cover D screws rawl plugs and documentation 3 SAFETY WARNINGS 3 1 When used in the extraction mode the cooker hood ducting must not be connected to a flue which is used for exhausting fumes from appliances supplied with energy other than electric such as a central heating flue or water ...

Страница 4: ...fan unit on this hood enables it to be installed in one of four different ways 1 Air outlet directed upwards ducting or recirculation fitting 2 Air outlet directed towards the wall ducting fitting only 3 Air outlet directed to the right or left ducting fitting only For correct installation of the hood please proceed in the following stages 4 1 Selection of the type of installation 4 2 Installation...

Страница 5: ...on Z of the chimney required for installation plus 11 mm X Z 18 7 Using a Ø8 mm drill bit drill the points marked in this way b When installed with the air outlet directed towards the wall fig 5a it will be necessary to drill an air ducting opening measuring Ø120 or 150 mm according to the diameter of the flange F provided 2 Fitting the fixing elements a Insert the rawl plugs provided into holes 1...

Страница 6: ...ig 9 d Adjust the support rod B so that it pushes against the wall fig 10 e Adjusting position fig 11 There are two adjustable hooks at the rear of the hood which can be used to adjust its position as follows Turn the screws L until the position of screws N coincides with the lower access holes Turn the screws N to adjust the vertical and horizontal position of the hood Lock the screws L to fasten...

Страница 7: ...w the line of shelves it will be necessary to drill a suitable hole in the top shelf only to allow the air ducting pipe to pass through fig 13 2 Direction and position of the ducting fan unit a The hood is normally supplied with the air towards the wall installed with the to the right or left be necessary to change of the ducting fan proceeding as follows Unscrew the screws Turn the ducting the ri...

Страница 8: ...ll the way out Remove the protective film P b Rest the lower section of the chimney in its housing on the top of the hood canopy Lower the ducting fan unit until it reaches the wall bracket S and fix it using the screw H provided fig 21 Fit the cover D provided on the wall bracket S fig 22 c Insert gasket G1 found in the accessory bag on the base of chimney stack A so that it adheres perfectly to ...

Страница 9: ...y after connection to the power supply 4 5 Connection to power supply and checking of good working order 1 It is absolutely necessary to follow the warnings 3 2 3 3 and 3 4 of paragraph 3 concerning safety measures 2 Loosen the two locking screws and remove the metal cover fig 26 Connect the hood connection to the engine connection fig 27a Correctly place the connectors under the cover and tighten...

Страница 10: ...rom licking round from the bottom of the pan this will save energy and will avoid a dangerous concentration of heat 1 4 Always ensure that the appliance is used in accordance with the manufacturer s instructions for the removal of contaminated air and odours during cooking 2 OPERATION Control Panel fig 28 The layout of the control panel is as follows Key Turns the lighting system on and off Key Tu...

Страница 11: ...suction motor Press the Speed button for at least 3 seconds until the LEDs flash in confirmation In any case the saturated filters alarm will only come into operation when the suction motor is turned on WARNING always comply with the maintenance and replacement times indicated in order to avoid a possible risk of fire when the filters are saturated with grease 3 2 Activated charcoal filter 1 Opera...

Страница 12: ...ollows Press the Speed button for at least 3 seconds until the LEDs flash in confirmation In any case the saturated filters alarm will only come into operation when the suction motor is turned on WARNING always comply with the maintenance and replacement times indicated in order to avoid a possible risk of fire when the filters are saturated with grease 3 3 Light 1 It consists of 2 20 W halogen sp...

Отзывы: