background image

Climate

for an ambient

classification

temperature of

SN

+10 to +32 °C

N

+16 to +32 °C

ST

+18 to +38 °C

T

+18 to +43 °C

Electrical connection 

Before plugging in, ensure that the voltage and
frequency shown on the serial number plate
correspond to your domestic power supply.

Voltage can vary by ±6% of the rated voltage.

For operation with different voltages, a suitably
sized auto-transformer must be used.

Important

The appliance must be earthed.

The power supply cable plug is provided with a
contact for this purpose.

If the domestic power supply socket is not earthed.
connect the appliance to a separate earth in
compliance with current regulations, consulting a
specialist technician.

The Manufacturer declines all responsibility if
the above safety precautions are not observed.

This appliance complies with the following
E.E.C.

Directives:

- 87/308 EEC of 2/6/87 relative to radio

interference suppression.

- 73/23 EEC of 19.2.73 (Low Voltage Directive)

and subsequent modifications.

- 89/336 EEC of 3.5.89 (Electromagnetic

Compatibility Directive) and subsequent
modifications.

Installation

Take utmost care when handling your
appliance so as not to cause any damages

to the cooling unit with consequent possible fluid
leakages.

During normal operation, the condenser and
compressor at the back of the appliance heat up
considerably. Always ensure that there is adequate
ventilation as a failure to do this will result in
component failure and possible food loss. See
installation instructions.

Important: if the supply cord is damaged, it must be
replaced by a special cord or assembly available
from the manufacturer or its service agent.

Positioning

Unpack the cabinet and check that it is in good
condition and free of any transport damage.

The appliance must not be located close to
radiators or gas cookers.

Avoid prolonged exposure of the appliance to direct
sunlight.

For safety reasons, minimum ventilation must be as
shown in Fig.

Attention: keep ventilation openings clear of
obstruction.

It is necessary that the niche is provided with a
conduct of venti-lation having the following
dimensions:

Depth: 50 mm

Width: 540 mm

The climate classification can be found on the rating
plate, which is located inside the cabinet on the left
hand wall.

The following table shows which ambient temperature
is correct for each climate classification:

23

GB

Содержание IKE 160-2T

Страница 1: ...t d emploi Wichtig Unbedingt lesen und aufbewahren Important Read these instructions carefully and then store them in a safe place Important Lire attentivement et ranger soigneusemnt ce mode d emploi Integrierte Kühlschrank Integrated Refigerator Réfrigérateur a intégrer Modell IKE 160 2T DE GB FR 2 14 15 26 27 38 ...

Страница 2: ...is product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product For mo...

Страница 3: ...ol Iternal parts 18 Door shelves Hints 19 Maintenance Defrosting 19 Cleaning 20 How to change the bulb 20 Something not Working 21 Customer Service and Spare Parts 22 Technical Specifications Door reversibility 22 Installation 23 Positioning Electrical connection 23 Building in 24 Cont Contents ents 16 GB ...

Страница 4: ... the appliance because they may explode Check and clean the outlet of melting water coming during defrosting regularly a label inside the appliance warns you for this If it is clogged the melting water gathered can cause earlier failure Precautions for child safety Do not allow children to play with the packaging of the appliance Plastic foil can cause suffocation Adults must handle the appliance ...

Страница 5: ... appliance is automatically adjusted Setting 1 hightest temperature warmest setting Setting 6 lowest temperature coldest setting Setting 0 Off A medium setting is generally the most suitable Internal Parts Storage shelves The shelves can be removed for cleaning To permit storage of food packages of various sizes the shelves can be placed at different heights To remove the internal shelf pull forwa...

Страница 6: ...ting effect so it reduces cooling efficiency as the temperature increases and it needs more energy At this type of appliance defrosting cooling compartment is automatic without any external intervention The thermostatic control interrupts the operation of compressor at regular intervals for more or less time during this cooling is interrupted temperature of the cooling compartment increases and de...

Страница 7: ...ineffective Remaining small ice and frost stains on back plate of the cooling compartment after defrosting period is not abnormal Cleaning Never use metal objects for cleaning your appliance as it may get damaged NEVER use detergents abrasive powders highly perfumed cleaning products or wax polishes to clean the interior as these will damage the surface and leave a strong odour nie Metallgegenstän...

Страница 8: ...emperature where the cabinet is placed is above normal room temperature Turn the temperature regulator to a warmer setting temporarily Turn the thermostat knob to a lower number The temperature where the cabinet is placed is above normal room temperature Check that the ventilation is sufficient and that the ventilation openings are unobstructed The cause could be the introduction of large quantiti...

Страница 9: ...ng plate inside the cabenit on the left hand wall We recommend that you enter this information here so that it is handy if needed Technical specifications The technical data is indicated in the rating plate on the left side inside the appliance Door reversibility The equipment is supplied with the door opening toward the right Follow the instructions below before installing it to have the door ope...

Страница 10: ...allation Take utmost care when handling your appliance so as not to cause any damages to the cooling unit with consequent possible fluid leakages During normal operation the condenser and compressor at the back of the appliance heat up considerably Always ensure that there is adequate ventilation as a failure to do this will result in component failure and possible food loss See installation instr...

Страница 11: ... follow indications in the figure 1 Fit the appliance in the niche by making sure that it stands against the interior surface of the unit on the side where the door hinges of the appliances are fitted Insert the appliance until the upper strip butts up against the unit 1 and make sure that the lower hinge is in line with the surface of the unit 2 2 Open the door and push the appliance against the ...

Страница 12: ... part marked with DX if the pivot pin is inserted in the right hinge SX in opposite case Apply covers C D on joint cover lugs and into hinge holes Snap hinge covers E into position 5 Separate parts Ha Hb Hc Hd as shown in the figure 25 GB 6 Place guide Ha on the inside part of the furniture door up and down as shown in the figure and mark the position of external holes After having drilled holes f...

Страница 13: ...the door of the furniture closes properly 11 Fix cover Hd on the small square Hb until it clips into place 8 Open the appliance door and the furniture door at 90 Insert the small square Hb into guide Ha Put together the appliance door and the furniture door and mark the holes as indicated in the figure 9 Remove the squares and mark a distance of 8 mm from the outer edge of the door where the nail ...

Отзывы: