Küppersbusch HI981420 Скачать руководство пользователя страница 6

18

ENG 

1

150/ 120 mm reduction.

Anti-recoil valve.

2

Supports for tubecover.

2

Supports hall.

6

Wall plugs (Ø8 x 40).

6

Long bolts (Ø5 x 45).

4

Wall plugs (Ø6 x 30).

4

Long bolts (Ø4 x 30).

2

Washers (Ø6,4 x Ø18).

2

Washers (Ø6,4 x Ø12).

2

Screws (Ø3,9 x 19).

4

Screws M4 x 12.

2

Clips.

Fig. 1 (Page 19)

On  installing  the  kitchen  hood  make  sure

that the Safety Instructions set out on page

14 are complied with.

To obtain optimum performance, the external

duct must not be more than FOUR METRES

LONG, have no more than two 90° angles and

its diameter must be at least Ø120.

1) Trace and drill the points for fitting the wall

plugs onto the wall (P) (Ø8 x 40) and (J) (Ø6 x

30).

2) Attach the Supports (O) to the wall using the

long  bolts  (Q)  (Ø5  x  45)  and  the  support  (H)

with the long bolts (I) (Ø4 x 30), as in figure 1.

3)  Hang  the  kitchen  hood  onto  the  mounted

supports  (O).  Straighten  the  appliance  by

tightening the long bolts (L) (M4 x 12).

4) Remove the metal filters. Loosen the screws

(without unscrewing them) of the EASYCLEAN

panels (A19), move the panels aside carefully

and  take  them  off.  Trace  the  location  of  the

long bolts (S) (Ø5 x 45).

5) Take the kitchen hood off.

6) Drill into the wall and fit the wall plugs (R)

(Ø8 x 40).

7) Hang the kitchen hood; tighten the screws

(M) (M4 x 12) with the washers (A3) (Ø6,4 x

Ø12) and the long bolts (S) (Ø5 x 45) with the

washers (T) (Ø6,4 x Ø18).

8) Mount the EASYCLEAN panel again (A19).

Fit the metal filters.

9)  Mount  the  tubecovers,  attaching  the  lower

one to the support (H) as per the detail in figure

1.  Lift  the  upper  tubecover  up  to  the  desired

height and mark its shape on the wall. Remove

the tubecovers.

10) Fit the clips (F) to the support (C). 

11) Centre the support (C) around the shape

marked; trace and drill the fixing points for the

wall plugs (E) (Ø6 x 30). Attach the support (C)

with the long bolts (D) (Ø4 x 30).

12) Fit the part (A) if the inner tubecover (not

supplied) is Ø150 or (A) + (B) if it is Ø120.

13)  Attach  the  inner  tubecover  with  a  clamp

(not supplied to (A) or (B) as the case may be.

14) Once the inner tube is fitted, fit the lower

tubecover around the extractor fan outlet and

attach the upper tubecover with the screws (G)

(Ø3,9 x 19).

When  exterior  gas  extraction  is  not  possible,

then the kitchen hood may be set to purify the

air  by  recycling  it  through  active  charcoal

filters.

The active charcoal filters have an active life of

between  three  to  six    months,  depending  on

the individual  conditions of use. These filters

cannot be washed nor regenerated. They must

be replaced once their useful life comes to an

end.

Fig. 2 (Page 19)

1) Remove the metal filters. Loosen the screws

(without unscrewing them) of the EASYCLEAN

panels  (K),  move  the  panels  aside  carefully

and take them off.

2) Put the filters into the lateral draught section

of  the  motor  making  the  holes  in  the  filters

match up (A) with the pivots (B) of the motor

carcass. Turn as indicated in the diagram.

3) Mount the EASYCLEAN panel again (K). Fit

the metal filters.

4) Remove the tubecovers (H). Fit the support

(J)  in  the  diffuser  (C).  Mount  the  connector

Ø150 (L) in the diffuser base.

5)  Use  the  wall  plugs  and  the  previously

installed  upper  tubecover's  support  (I)  long

bolts (D) (Ø4 x 30) to fix diffuser into the wall

(C). 

6) Connect the connector base (L) to the motor

exit  via  the  inner  tube  (not  supplied).  Use

clamps (Not supplied). Fit the tubecovers (H)

again. 

Active charcoal filters  (Optional)

Installation

Accesories supplied

Отзывы: