background image

19

GB

12r

Vr

ø 150

9

ø 120

14.1

15

Mounting the hood body

• Before attaching the hood body, tighten the two

screws Vr located on the hood body mounting
points.

• Hook the hood body onto the screws 12r (4,2 x

12,7).

• Fully tighten support screws 12r (4,2 x 12,7).
• Adjust screws Vr to level the hood body

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using either a flexible or rigid
pipe ø 150 or 120 mm, the choice of which is left to the installer.

• To install a ø 120 mm air exhaust connection,

insert the reducer flange 9 on the hood body
outlet.

• Fix the pipe in position using sufficient pipe

clamps (not supplied).

• Remove any activated charcoal filters.

RECIRCULATION VERSION AIR OUTLET

• Push fit connection 15 onto the air outlet.
• Insert the connection extension pieces laterally

14.1 in connection 15.

• Make sure that the outlet of the extension pieces

14.1 is horizontally and vertically aligned with
the chimney outlets. If this is not the case, adjust
the position by either reversing the connection
extension pieces 14.1 or by pushing connector
15 all the way in.

• Ensure that the activated charcoal filters have

been inserted.

Содержание EKD 10650.0E-84

Страница 1: ...EKD 10650 0E 84 Bedienungsanleitung Instructions Booklet Mode d emploi Libretto Istruzioni Gebruiksaanwijzing Manual de instrucciones Manual de instruções NL IT FR GB DE ES Εγχειρίδιο οδηγιών PT GR ...

Страница 2: ...recommendations contained in this Instruction Manual your appliance will give you constant high performance and will remain efficient for many years to come RECOMMENDATIONS AND SUGGESTIONS 15 CHARACTERISTICS 16 INSTALLATION 18 USE 21 MAINTENANCE 22 ...

Страница 3: ...nt degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has ben designed Never lea...

Страница 4: ...16 GB CHARACTERISTICS Dimensions 650 min 400 905 582 962 1 0 0 0 740 68 min 820 310 78 max 1140 493 1414 122 ...

Страница 5: ...mprising 2 1 1 Upper Section 2 2 1 Lower Section 9 1 Reducer Flange ø 150 120 mm 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 1 1 Hood Connector Support 7 2 1 2 Upper Chimney Section Fixing Brackets 11 12 Wall Plugs 12a 12 Screws 4 2 x 44 4 12e 6 Screws 2 9 x 9 5 12r 2 Screws 4 2 x 12 7 Q ty Documentation 1 Instruction Manual ...

Страница 6: ...e centres of the holes in the bracket Place the Hood Connector Support 7 1 on the wall as shown at 357 mm above the horizontal reference line making sure that the holes used to fix the corner to the wall are equidistant Mark the wall at the centres of the holes in the Support Drill ø 8 mm holes at all the centre points marked Insert the wall plugs 11 in the holes Fix the brackets and the Support u...

Страница 7: ...o the installer To install a ø 120 mm air exhaust connection insert the reducer flange 9 on the hood body outlet Fix the pipe in position using sufficient pipe clamps not supplied Remove any activated charcoal filters RECIRCULATION VERSION AIR OUTLET Push fit connection 15 onto the air outlet Insert the connection extension pieces laterally 14 1 in connection 15 Make sure that the outlet of the ex...

Страница 8: ...on the side of the fan Flue assembly Upper exhaust flue Slightly widen the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using the 4 screws 12e 2 9 x 9 5 supplied Lower exhaust flue Slightly widen the two sides of the flue and hook them between the upper flue and the wall making sure that they are well sea...

Страница 9: ... for about 2 seconds After 10 minutes of functioning it turns off automatically This function can be interrupted by means of pressing any of the buttons S1 Led Fixed Indicates that the Metal grease filters saturation alarm has been triggered and the filters need to be washed The alarm is triggered after 100 working hours Reset check the Maintenance paragraph Flashing indicates that the activated c...

Страница 10: ...leaning the filters The filters are washable and must be cleaned when led S1 flashes or at least every 2 months of operation or more frequently for particularly heavy usage Remove the filters one at a time by releasing the fixing hooks Wash the filters taking care not to bend them Allow them to dry before refitting When refitting the filters make sure that the handle is visible on the outside ...

Страница 11: ...oods the Filter saturation alarm can be enabled on installation or at a later date Turn the Lights and the suction Motor off Disconnect the Hood using the Main switch or the double pole switch on the mains power supply Restore the connection by pressing and holding T1 Release the button All five LEDs are turned on Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation LED flashes twi...

Страница 12: ...PERSBUSCH Hausgeräte AG Küppersbuschstraße 16 D 45883 Gelsenkirchen Hausanschritt Küppersbuschstr 16 45883 Gelsenkirchen Telefon 02 09 4 01 0 Telefax 20 931 810 Telefax 02 09 4 01 3 03 436002156_01 040409 ...

Отзывы: