Installation instructions EEB 9600.0

Options for mounting under a countertop

Option 1: in a cupboard on a board.

Option 2: between two cupboards on a se-
cured board.
Boards (approximately 19 mm/ 3/4" thick) 
must be attached to the adjacent cabinets 
on the right and left, so the oven can be 
clipped in at the sides.

The following KÜPPERSBUSCH built-in cooktops may be installed above the 
oven:

F

* The gap between the countertop and the front panel is not necessary 
for the models EGS 304.2 and EKS 304.1.
We recommend you to place the gap directly below the countertop, be-
cause it’s not so visible if it is between the oven an the front panel.

F

Look for the recess size and installation specifics for the cooktop in the 
installation instructions for the cooktop.

Installation under the 
Cook-Center KC 906.2 E

The oven must be positioned between 
two cabinets on a secured shelf. Shel-
ves (approximately 19mm/ 
9/16" thick) must be attached to the 
adjacent cabinets on both sides so the 
oven can be clipped in at the sides.

Please review the installation instruc-
tions for the model KC 906.2 for the 
position of the Cook-Center.

Be sure to install a stain-
less steel filler panel (acc. 
No. 454) between the 
Cook-Center and the oven. 
The stainless steel filler 
panel is required and sold 
separately.

Model:

„A“

„B“

„C“

EKE 854.1
EKE 854.2
EKE 804.2
EKE 604.2

30

-5

0

 mm

1

-1/

8 t

o 2

"

103 mm

4-1/16"

 103 mm

 4-1/16"

EGS 304.0*

97 mm

3-13/16"

 97 mm

 3-13/16"

EKS 304.1*

85 mm

3-3/8"

 85 mm

 3-3/8"

EKS 604.2
EKS 804.2

103 mm

4-1/16"

 103 mm

 4-1/16"

Содержание EEB 9600.0

Страница 1: ...Installation instructions Important Save for the local electrical inspector s use EEB 9800 0 EEB 9600 0 072444 IC1 ...

Страница 2: ...pro vided free of charge All warranty service will be provided by an authorized technician during normal business hours What Isn t Covered Service by an unauthorized agency will not be reimbursed Likewise the warranty doesn t cover any damage or repairs due to service performed by an unauthorized agency or by the use of unauthorized parts Service visits to teach you how to use the appliance Servic...

Страница 3: ...abinet or adjacent side walls must be secured so the installed oven can t tilt Make sure there s an opening in the rear section in order to provide sufficient air for cooling the oven If there isn t an opening cut a hole with at least 300 cm2 45 in2 depth in one of the adjacent surfaces preferably in the bot tom board or top cover Make sure all components surrounding the oven can resist temperatur...

Страница 4: ...he recess size and installation specifics for the cooktop in the installation instructions for the cooktop Installation under the Cook Center KC 906 2 E The oven must be positioned between two cabinets on a secured shelf Shel ves approximately 19mm 9 16 thick must be attached to the adjacent cabinets on both sides so the oven can be clipped in at the sides Please review the installation instruc ti...

Страница 5: ...d grounding must comply with all stan dards The conduit box must be protected by a circuit breaker or fuse having amperage as noted in this chapter Connected load 240 V 60 Hz 3 6 kW fuse current 15 A Connect the cable to the conduit box Installation in kitchen furniture Screw the provided clips to both sides of the appliance using the holding pla tes mounted in the cabinet The holding plates are s...

Страница 6: ...ERSBUSCH USA 4920 W Cypress Street Suite 106 Tampa Florida 33607 Telephone 800 459 0844 Fax 813 288 8604 Customer Care line 1 800 459 0844 www kuppersbuschusa com KÜPPERSBUSCH USA is a division of Teka USA ...

Отзывы: