• Once the kitchen hood has been installed,

ensure that the feed cable to the network is
not in contact with any live metal edges.

• Avoid connecting the apparatus to

conductors used exits for fumes produced
by a non-electric energy source. E.g.:
boilers, chimneys, etc.

• If the extractor fan is going to be used

simultaneously with equipment powered by
a non-electric energy source. E.g.:  gas
cookers, the room must have sufficient
ventilation.

• The lower part of the kitchen hood must be

fitted at least 60 cm. (23,6 in) over electric
hobs and 65 cm. (25.6 in) over gas or mixed
hobs.

• Avoid cooking under the kitchen hood if the

metal filters are not fitted, e.g.: while they
are being cleaned in the dishwasher.

• We recommend the use of gloves and to be

extremely careful when cleaning the kitchen
hood's interior.

• Your kitchen hood is designed for domestic

use and only for extraction and purification
of gases produced during food preparation.
It will be your responsibility if it is used for
other purposes, which may be dangerous.
The manufacturer cannot accept responsi-
bility for damage caused by improper use of
the apparatus.

• For repairs please contact the nearest

KÜPPERSBUSCH

Technical Assistance

Service, and always use genuine spare
parts. Repairs or modifications effected by
unqualified personnel can cause
malfunctions or may damage the
apparatus, putting  your safety in danger.

Index

Page

Description of the apparatus

3

Instructions for use

4

Programming timer

4

Cleaning and maintenance

4

Problem solving                    

5

Sizes and specifications

5

Accessories supplied

6

Grounding instructions

6

Installation

7

Active charcoal filters

8

A

Electronic programmer control box with
buttons to control speed, light and
power in use indicators.

B

Metal filters.

C

Lamp with two lights - 20 W (G-4).

D, E

Vertically adjustable tubecovers.

F

Decorative part. ( No incluided ). 

3

ENG 

Description  of the apparatus

Manual ND ISLA UL ing.qxd  6/05/2003  11:50  PÆgina 3

Содержание IKD 1157.1 GE

Страница 1: ...INSTRUCTIONS FOR USE AND INSTALLATION INSTRUCTIONS IKD 1157 1 GE UL Manual ND ISLA UL ing qxd 6 05 2003 11 50 PÆgina 1 ...

Страница 2: ... cannot be locked securely fasten a prominent warning device such as a tag to the service panel WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings b Always turn hood ON when cooking at high heat or when cooking flaming foods c Clean ven...

Страница 3: ...ction and purification of gases produced during food preparation It will be your responsibility if it is used for other purposes which may be dangerous The manufacturer cannot accept responsi bility for damage caused by improper use of the apparatus For repairs please contact the nearest KÜPPERSBUSCH Technical Assistance Service and always use genuine spare parts Repairs or modifications effected ...

Страница 4: ...r corrosive products Dry the kitchen hood using a cloth that does not produce fluff To remove the filters from their fittings press lightly on the locks and then pull them off The metal filters can be cleaned by soaking them in hot water with neutral detergent until the fat dissolves and then rinsing them under the tap or using products specially designed for fats They can also be washed in a dish...

Страница 5: ...current in the network Connect feed cable to the network Check that the network has electrical current The extractor ceases to educt strongly or vibrates Filters are saturated with fat Obstruction in the air exit conduct Change or clean the active charcoal and or metal filters as the case may be Eliminate the obstruction The lamps do not light up The lamps are burnt out The lamps are loose Change ...

Страница 6: ...lectrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is plugged into an outlet that is properly installed and grounded WARNING Improper grounding can result in a risk of electric shock Consult a qualified electrician if the grounding instructions are not completely understood or if doubt exists as to whether the ap...

Страница 7: ...ngles and its diameter must be at least Ø120 Fig 1 Pag 8 1 Using the support O trace and drill the points for fitting the lock screws S Ø8 x 45 onto the ceiling 2 Screw the support O into the ceiling with the lock screw S Ø8 x 45 3 Mount the top inner body A6 in the support O with the screws Q M6 x 16 4 Softly attach the decorative handle W to the decorative glass part U with the screws X M5 and t...

Страница 8: ... the support O trace and drill the points for fitting the lock screws S Ø8 x 45 onto the ceiling 2 Screw the support O into the ceiling with the tirafondos anclaje S Ø8 x 45 3 Mount the top inner body A6 in the support O with the screws Q M6 x 16 4 Softly attach the decorative handle W to the decorative glass part U with the screws X M5 and the washer Y provided with the glass 5 Adjust the decorat...

Страница 9: ... 11 Mount the bottom group to the top fixed to the ceiling with the screws A10 M4 x 12 to the desired height 12 Mount the part A5 with the screws A4 M4 x 12 in the rectangle parts of the top inner body A6 13 Lift the upper tubecover A8 up to the desired height and fix it to the top group with the screws G M4 x 12 flat head 14 Adjust finally the decorative glass part U fixing it to the body of the ...

Отзывы: