Always disconnect the appliance from the

electricity and gas mains before proceeding

with any servicing operation.

13) REPLACING HOT PLATE PARTS

Replacement of the components housed inside

the appliance: remove the trivets and the burners

from the upper part of the working table; remove

the fixing screws "V" of the burner (fig. 15) and the

knobs fixed by pressure with the hans, in order to

take off the appliance.

After having carried out the above listed operations,

the burners (fig. 16), taps (fig. 17) and electrical

components can all be replaced (fig. 18).

NB: 

the ignition bar must be removed before

replacing the taps in appliances with automatic

ignition systems.

It is advisable to change seal “D” whenever a tap is

replaced to ensure a perfect tightness.

Greasing the taps (see fig. 19 - 20)

If a tap becomes stiff to operate, it must be

immediately greased in compliance with the

following instructions:

- remove the tap.

- Clean the cone and its housing using a cloth

soaked in diluent.

- Lightly spread the cone with the relative grease.

- Fit the cone back in place, operate it several times

and then remove it again. Eliminate any excess

grease and check that the gas ducts have not

become clogged.

- Fit all parts back in place, complying with the

demounting order in reverse.

- The tight closure test must be done using a foamy

liquid. 

The use of the flame is prohibited.

To facilitate the servicing technician’s task, here is a

chart with the types and sections of the powering

cables and the ratings of the electrical components.

30

 

Содержание GMS 6540.0 E

Страница 1: ...e indicated on the cover of the instruction manual and on the appliance itself The manufacturer shall not be held responsible for any damages to persons or property caused by incorrect installation or...

Страница 2: ...upport 2F 7 Enamelled steel pan support central 8 Burner n 1 control knob 9 Burner n 2 control knob 10 Burner n 3 control knob 11 Burner n 4 control knob 12 Burner n 5 control knob 13 Electric ignitio...

Страница 3: ...consumption use adequate pans for each burner consult the following table and fig 2 When the pan comes to the boil set the knob to the reduced rate position small flame fig 1 Always place a lid on th...

Страница 4: ...ts clear fig 3 and by activating the mechanical aeration device suction hood or electric fan fig 4 and fig 5 Intensive and lengthy use of the appliance may require additional ventilation This can be a...

Страница 5: ...alted water lemon or tomato juice from remaining in contact with the enamelled surfaces for long periods of time WARNINGS comply with the following instructions before remounting the parts check that...

Страница 6: ...iven for the hole into which the appliance will be recessed see fig 7 and 8 The appliance belongs to class 3 and is therefore subject to all the provisions established by the provisions governing such...

Страница 7: ...ances must always dispose of their combustion fumes through hoods These must be connected to flues chimneys or straight outside see fig 4 If it is not possible to install a hood an electric fan can be...

Страница 8: ...positioned so that no part of it is able to reach an overtemperature of 65K Never use reductions adapters of shunts for connection since these could create false contacts and lead to dangerous overhe...

Страница 9: ...apply this seal detach the seals from their backing checking that the transparent protection still adheres to the seal itself Overturn the hot plate and correctly position seal E fig 9 under the edge...

Страница 10: ...1 Remove knob M fig 13 of the tap which is simply pressed on to its rod Insert a small screwdriver D into hole C fig 13 and turn the throttle screw to the right or left until the burner flame has been...

Страница 11: ...unting injectors suited to the type of gas in question To do this first remove the burner tops using a wrench B Now unscrew injector A see fig 14 and fit a injector corresponding to the utilized type...

Страница 12: ...h automatic ignition systems It is advisable to change seal D whenever a tap is replaced to ensure a perfect tightness Greasing the taps see fig 19 20 If a tap becomes stiff to operate it must be imme...

Страница 13: ...remove exausty battery Insert a 1 5 V new battery The positive polarity is turn over inside Rescrew the cap T Re assembly all the movable parts WARNING the batteries contain a dangerous material for o...

Страница 14: ...F TYPE OF SINGLE PHASE HOT PLATE CABLE POWER SUPPLY CABLE TYPES AND SECTIONS ATTENTION If the power supply cable is replaced the installer should leave the ground wire longer than the phase conductors...

Страница 15: ...Gas Rate 10 05kW Qn LPG Gas Rate 731 g h Voltage 230 240 V Frequency 50 60 Hz 4 BURNERS 60 WITH BATTERY CATEGORY II2H3 G 30 BUTANE 28 30mbar G 31 PROPANE 37 mbar G 20 NATURAL 20 mbar Qn LPG Gas Rate...

Страница 16: ...TECHNICAL DATA FOR THE APPLIANCE GAS REGULATION 34...

Страница 17: ...enter whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spare parts are only available from our...

Страница 18: ...36...

Отзывы: