background image

3

SAFE GUARD INSTRUCTIONS

1) SAFE GUARD INSTRUCTIONS

For all appliances:

- the product shall be installed according with the a statement that the installation must conform with local

codes or, in absence of local codes, with the 

National Fuel Gas Code, ANSI Z223.1/NFPA 54.

- The product must be electrically grounded in accordance with local codes or, in the absence of local

codes, with the 

National Electrical Code, ANSI/NFPA 70.

- The appliance and its individual shutoff valve must be disconnected from the gas supply piping system

during any pressure testing of that system at test pressure in excess of  ½  psi (3.5 kPa). The maximun

gas supply pressure is 4 inch WC and 11 inch WC and the gas pressure regulator provided is regulated

to 1 inch water column above the manufacturer’s specified manihold pressure.

- Always disconnect all cord connect appliances shall include instructions relative to location ot the wall

receptacle and the warning to the user to disconnect the electrical supply before servicing the

appliance. 

- Save the orifices removed from the appliance for  future use.

- When a flexible service cord of the grounding type is provided to connect the appliance to a line-voltage

electrical supply, the instructions shall also include the intent of the warning statement specified in

1.29.12.

- The maximum depth cabinets  installed above cooking tops be 13 in. (330 mm).

- Keeping appliance area clear and free from combustible materials, gasoline, and other flammable vapors

and liquids.

- Not obstructing the flow combustion and  ventilation air.

WARNING:  If the information on this manual is not followed

exactly, a fire or explosion may result causing property

damage, personal injury or death.

-  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any

other appliance.

-  WHAT TO DO IF YOU SMELL GAS

-  Do not try to light any appliance.

-  Do not touch any electrical switch; do not use any phone in your building.

-  Immediately call your gas supplier from a neighbor’s phone.  

Follow the gas supplier’s instructions.

-  If you cannot reach your gas supplier, call the fire department.

-  Installation and service must be performed by a qualified installer; service agency or the

gas supplier.

Содержание GKS 3720.0 M-UL

Страница 1: ... any damages to people or to things in the event of incorrect installation or improper use of the appliance INSTRUCTIONS AND RECOMMENDATIONS FOR THE USE INSTALLATION AND MAINTENANCE OF BUILT IN GAS CERAMIC HOBS MODELS GKS 3720 0 M UL GKS 6740 0 M UL GKS9751 0 M UL COD 04064ULKUP 04 06 2009 The Manufacturer cannot be held responsible for any imprecision due to printing or copying errors contained i...

Страница 2: ...MODEL GKS 3720 0 M UL 1 DUAL burner total simmer 13000 14500 Btu h 2550 3200 Btu h 2 Fast burner 8350 Btu h 3 Semi fast burner front 4350 Btu h 4 Semi fast burner back 4350 Btu h 5 Auxiliary burner 3400 Btu h 6 1F DUAL grill 7 2F grill 8 Burner no 1 control knob 9 Burner no 2 control knob 10 Burner no 5 control knob 11 Burner no 4 control knob 12 Burner no 3 control knob ...

Страница 3: ...g the appliance Save the orifices removed from the appliance for future use When a flexible service cord of the grounding type is provided to connect the appliance to a line voltage electrical supply the instructions shall also include the intent of the warning statement specified in 1 29 12 The maximum depth cabinets installed above cooking tops be 13 in 330 mm Keeping appliance area clear and fr...

Страница 4: ...ch burner consult the following table and fig 2 When the pan comes to the boil set the knob to the reduced rate position small flame fig 1 Always place a lid on the pans Use only pan with a flat bottom WARNINGS burners with flame failure device may only be ignited when the relative knob has been set to the Full on position large flame fig 1 Matches can be used to ignite the burners in a blackout N...

Страница 5: ...ner and outer flame at the same time LIGHTING AND USING THE DUAL BURNER Stand the pan on the burner before lighting Despite being controlled by a single knob the DUAL burner can be used in two different ways A Using the complete burner Starting from the off position You must first press the knob simultaneously turning it anti clockwise until the indicator points to the maximum delivery position ob...

Страница 6: ...d Intensive and lengthy use of the appliance may require additional ventilation This can be achieved by opening a window or by increasing the power of the mechanical exhausting system if installed WARNING NEVER use this appliance as a space heater to heat or warm the room Doing so may result in carbon monoxide poisoning and overheating ot the oven ...

Страница 7: ...e degree of dirt we recommend for light stains a damp sponge is sufficient Tough encrusted dirt is easily eliminated using a scraper fig 3 not supplied with the hob but easy to find in local stores Use the scraper carefully to avoid damaging the hob Traces of liquid spilled from pans can be eliminated with vinegar or lemon juice Never allow sugar or sugary foods to fall on the hob while cooking Sh...

Страница 8: ...s Ensure that the enamelled covers A B and C fig 4 and 4 A are correctly positioned on the burner head The covers are correctly positioned on the head when they are perfectly stable If the opening and closing of any valve is awkward do not force it but request urgent intervention by the technical assistance service Do not use jets of steam to clean the appliance To prevent difficulties with lighti...

Страница 9: ...to which the hot plate will be installed are indicated in either fig 6 Always comply with the measurements given for the hole into which the appliance will be recessed see fig 6 and 7 5 FIXING THE HOT PLATE The hot plate has a special seal which prevents liquid from getting into the cabinet Strictly comply with the following instructions in order to correctly apply this seal detach the seals from ...

Страница 10: ...er edge of the seal perfectly matches the outer perimeter edge of the glass The ends of the strips must match without overlapping Stick the seal to the glass evenly and securely using your fingers to press it into place In order to avoid accidental contact with the surface of the box of the overheated hob during use it is necessary to install a wooden divider at a minimum distance of 150 mm from t...

Страница 11: ...e appliance on purchase Assemble the regulator noting the gas flow direction and transition pieces supplied with the appliance in accordance with below figure The transition piece on the supply side of the regulator must be provided by the installer Unions compatible with the hose fittings must be used and connections tested for gas leaks Ensure the supply connection point is accessible with the a...

Страница 12: ...the data label to the cable Fit the wires following figure 10 taking care of respecting the following correspondences Letter L live wire Letter N neutral wire earth symbol green or yellow green wire Never use reductions adapters of shunts for connection since these could create false contacts and lead to dangerous overheating The outlet must be accessible after the built in When the appliance is c...

Страница 13: ...s of the strips must fit together without overlapping Evenly and securely fix the seal to the hot plate pressing into place with the fingers and remove the strip of protective paper from the seal and set the plate into the hole made in the cabinet Fix the hob with the proper brackets S and turn the screw F until the bracket S stick on the top fig 12 The prospective walls left or right that exceed ...

Страница 14: ...lame has been adequately regulated to the Reduced rate position Check that the flame does not go out when the knob is sharply switched from the Full on to the Reduced rate position It is understood that only burners operating with Natural Gas or Town gas should be subjected to the above mentioned adjustments The screw must be fully locked when the burners operate with Propane HD 5 turn clockwise I...

Страница 15: ...ously applied This label is contained in the spare nozzle bag For the ease of the fitter we have prepared a table indicating the flow capacities the heat capacities of the burners the diameter of the nozzles and the working pressure for the various types of gas ARRANGEMENT OF THE BURNERS FIG 14 BURNERS GAS NORMAL PRESSURE inches water column INJECTOR DIAMETER 1 100 mm NOMINAL HEAT INPUT Btu h N DE...

Страница 16: ... automatic ignition systems It is advisable to change seal D whenever a tap is replaced to ensure a perfect tightness Greasing the taps see fig 19 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions remove the tap Clean the cone and its housing using a cloth soaked in diluent Lightly spread the cone with the relative grease Fit the cone ba...

Страница 17: ...oltage 120 V AC Frequency 60 Hz 4 BURNERS 60 PROPANE HD 5 11 inches water column NATURAL GAS 7 inches water column Σ Qn Natural Gas 20450 Btu h Σ Qn Propane HD 5 20450 Btu h Voltage 120 V AC Frequency 60 Hz 5 BURNERS 90 PROPANE HD 5 11 inches water column NATURAL GAS 7 inches water column Σ Qn Natural Gas 34950 Btu h Σ Qn Propane HD 5 33450 Btu h Voltage 120 V AC Frequency 60 Hz ...

Страница 18: ...fied personnel This is why we recommend that you always contact the Dealer who sold the appliance or our nearest Assistance Centre specifying the brand the model the serial number and the type of problem affecting your appliance The pertinent data is stamped on the label applied to the underside of the appliance and on the label applied to the packing box This information enables the technical ass...

Страница 19: ...Kuppersbusch USA 1883 Massaro Blvd Tampa FL 33619 Toll 800 459 0844 P 813 288 8890 F 813 288 8604 ...

Отзывы: