H2-120-01-01
21
For internal use only
6.3
Functional Testing
After the appliance has been completely re-assembled a functional testing is to be performed!
Put the appliance into service in accordance with these operating instructions.
Check the appliance for gas leakage (see DVGW working sheet G600 / DVGW TRGI/ 1986 / TRF 1988).
Check burners for overignition and regular flame aspect (also in low setting).
Provide respective nameplates for the newly set gas type in an appropriate location.
6.4
Injector Diameter
Injector marking main injector/low setting-injector
Gas type
High-speed
burner
Normal
burner
Simmering
burner
Natural gas H, E, E+
G 20 (20/25 mbar)
125/56
93/45
72/41
Natural gas LL
G 25 (20 mbar)
145/62
117/50
79/47
Natural gas L
G 25 (25 mbar)
118/57
104/47
78/43
LPG Butane/Propane
G 30 (50 mbar)
75/33
60/27
47/24
LPG Butane/Propane
G 30 (28-30/37 mbar)
83/39
70/31
53/28
LPG Propane
G 31 (50 mbar)
79/34
67/29
51/26