H1-01-08
9
For internal use only
2.6
Automatic boost function
All cooking zones have an automatic initial cooking function. The parboiling boost is activated at full
power. The parboiling boost time depends on the subsequent cooking level which has been selected
after the activation. The cooking zone automatically changes to the selected subsequent cooking level
as soon as the set parboiling boost time has elapsed.
Selecting the required setting by means of the minus sensor key will
automatically activate the automatic boost function.
During automatic operation an “A” will flash in the display in alternation
with the cooking level set.
If the automatic boost function is to be activated when the required
setting is selected by means of the plus sensor key, the plus sensor
key must be touched again once power level 9 has been reached.
Then set it at the required cooking level.
An “A” will flash in the display in alternation with the cooking level set.
2.7
Multi-circuit cooking zone and frying zone
As a standard rule, the smallest cooking zone diameter is heated. Switch on the outer cooking zone
circuit for large pots.
Dual-circuit zone and frying zone
Touch the cooking zone symbol next to the Plus/Minus sensor keys.
When the dual-circuit cooking zone has been activated a dot will be
shown in the cooking setting display on the bottom right. Touching the
cooking zone symbol again will deactivate the dual-circuit zone and
the frying zone.
Triple-circuit zone and frying zone
Touch the cooking zone symbol next to the Plus/Minus sensor keys.
When the middle cooking zone has been activated a flashing dot will
be shown in the cooking setting display on the bottom right.
Touch the cooking zone symbol once again.
When the outer cooking zone has been activated a dot will be shown
in the cooking setting display on the bottom right. Touching the
cooking zone symbol again will switch both of the outer cooking zones
off together.
2x