Electric oven
TECHNICAL PASSPORT
Ex.start 0.00:0.01/0.02/0.03/0.04/0.05/
0.06/0.07 /0.08/0.09/0.10/0.20/0.30/0.4
0/0.50/1.00/1.30/2 .00/2.30/…
Ex.start 1.23:1.24/1.25/1.26/1.27/1.28/
1.29/1.30 /1.31…/1.39/1.40/1.50/2.00/2
.10/2.20…/2.30/3. 00/3.30/…
3.3 Minute Minder
Function
Minute minder program only lets the
buzzer sound when alarm time has
finished. No relays are switched. Time
setting steps and ranges are described
in chapter 1.5 [m] and 4.2. The minute
minder runs independently of other
programs.
Setting alarm time
Select minute minder function by
successive pressing MODE button.
In alarm time setting mode, alarm
time stops running down and the Bell
symbol flashes quickly. The symbols of
other active programs are illuminated
statically.
Program run
The display shows the expiring alarm
time while the Bell symbol is flashing
slowly. If alarm time is <60s, the display
reads the alarm time in seconds 0:ss,
else in hours and minutes hh:mm.
Minute minder end
If alarm time has run down, the display
reads 0:00, an acoustic interval signal
sounds and the Bell
symbol flashes quickly. Program end
is cleared by pressing any key or
automatically after timeout.
3.4 Semi Automatic Program with
Duration or End Time
Function
The relay is switching dependent on
set duration or end time. Automatic
program time is running down in steps
of 1 minute. Time setting steps and
ranges are described in chapter 1.5 [a]
and 4.2. Note: At EPT1, only one relay
(relay 1) is used. Else both relays (relay
1&2) are switched together at automatic
program, but only if the oven is on. If the
oven is off, an automatic program runs
down just like a timer without any effect
to the relays.
Setting Program Time
Select either duration or end time
setting mode by successive pressing
MODE button. Duration or end time
symbol is flashing quickly. The symbols
of other active programs are illuminated
statically. End time and duration are
linked by: End time = Actual time +
Duration. If a program duration is set,
the end time cannot be reduced. Neither
can the program duration be extended,
when an end time is set.
Program run
While semi automatic program is
running, the relay contact is closed.
Duration or End time symbol is flashing
slowly while the display reads duration
or end time.