background image

Gateway PROFINET IRT Slave

24

6 Integrated Servers

6.1 FTP-Server

The  FTP  server  is  necessary  for  updating  HTML  files  of  the  web  server  and  for  transmitting
firmware updates to the module.

You can access the FTP server from user level 2. For this purpose, the same logon data as for the
web server is valid. The "Level" is defined in the file "password.xml". How to do this is explained in
the section 

"Logging on to the web server" [

}

 24].

Web Server Files

You will find files for the web server in the "Web" subfolder.

6.2 Webserver

The Gateway has a web server. You can access it from any browser.

Calling the Web Server

a) Verbinden Sie das Gateway mit dem PC.

b) Open your browser.

c) Enter the IP address as a URL (e.g. : http://192.168.0.8)

ð

You can log in now.

Logging on to the Web Server

You can log on to the web server as an administrator or as a user.

The user may:

– Read process data of the Gateway .

Credentials (default):

User name User

Password: 1111

The administrator may:

– Change passwords

– Change network settings

Credentials (default):

User name Admin

Password: 1701

Tip! As admin you can change the password directly in the web server.

Display Process Data

For the interfaces in the selected mode, the transmitted data can be displayed cyclically.

Click  the  "Show"  buttons  to  view  the  process  data  of  the  desired  input  and  output  range.  The
following example shows the process data of the fieldbus.

Integrated Servers

Содержание PROFINET IRT Slave

Страница 1: ...User Manual Gateway PROFINET IRT Slave DO0413R00 3 31 2022...

Страница 2: ...2 Control Elements 9 3 3 Status LEDs 12 4 Installation 13 4 1 Preparations for Inteference free Operation 13 4 2 Requirements 14 4 3 Connecting Gateway Components 15 4 4 Installing a Gateway in the Co...

Страница 3: ...tion for damages Trademark Protection KUNBUS is a registered trademark of KUNBUS GmbH Windows and Microsoft are registered trademarks of Microsoft Corp KUNBUS GmbH Heerweg 15 C 73770 Denkendorf German...

Страница 4: ...s caused by technical modification to the product e g soldering 1 5 Customer Service If you have any questions or suggestions concerning this product please do not hesitate to contact us KUNBUS GmbH H...

Страница 5: ...alled and put into operation by trained qualified personnel Before assembly it is absolutely essential that this documentation has been read carefully and understood Expertise in the following fields...

Страница 6: ...n against contact the following alternative types of installation are specified a Installation in a suitable cabinet b Installation in a suitable enclosure c Installation in a suitable equipped enclos...

Страница 7: ...is permitted b Immediately change the default password for the web server Select a secure new password You can find current information on this at https www bsi bund de EN Home home_node html c Check...

Страница 8: ...mbine these gateway components as you wish This design offers you a high degree of flexibility since you can exchange the individual gateway components at any time The following gateway components are...

Страница 9: ...Gateway PROFINET IRT Slave 9 3 2 Control Elements Front view 1 2 Illustration 2 Front view 1 Status LEDs 2 Fieldbus connection two RJ45 sockets for the connection to PROFINET Overview...

Страница 10: ...ay PROFINET IRT Slave 10 Top 1 1 2 Illustration 3 Top 1 Interconnect ports for interconnecting the gateway components 2 Locking clamps for securely attaching the gateway component to the DIN rail Over...

Страница 11: ...Gateway PROFINET IRT Slave 11 Bottom 1 2 Illustration 4 Bottom 1 Mains connection with 24 V supply voltage 2 Locking clamps for securely attaching the gateway component to the DIN rail Overview...

Страница 12: ...lashes green Data packets sent or received Link Traffic Port 2 off No connection to a network on green Network cable is plugged in flashes green Data packets sent or received Run off No connection to...

Страница 13: ...r bundles Cables of group A and B Route the groups in separate bundles or in cable ducts at a minimum distance of 10 cm from each other Cables of group C Route the groups in separate bundles or in cab...

Страница 14: ...the DIN rail horizontally in the control cabinet according to the manufacturers specifica tions Make sure that the Gateway module has sufficient distance to other devices NOTICE Your gateway could be...

Страница 15: ...components a Connect an interconnect port to each gateway component using the plug in jumper provided Illustration 6 Connecting gateway components You can now install the gateway in the control cabine...

Страница 16: ...ments towards the gateway c Make sure that the gateway is firmly attached to the DIN rail 4 5 Connecting a Gateway to the Fieldbus To connect the gateway component to PROFINET you need two RJ45 connec...

Страница 17: ...ower supply for each gateway component and make sure that the GND are connected to each other at the power supply Connect FE to PE with low resistance NOTICE Connect the two gateway components to the...

Страница 18: ...string type Limitation to a total of 240 characters letters a to z digits 0 to 9 hyphen or dot A name element of the device name must be separated by a dot and can have a maximum of 63 characters No...

Страница 19: ...000060 Input Off 32 12 Output 32 0x00000060 Input Off 64 13 Output 32 0x00000060 Input Off 96 14 Output 64 0x00000070 Input Off 128 15 Output 64 0x00000070 Input Off 192 16 Output 64 0x00000070 Input...

Страница 20: ...Description Input 32 Byte Module ID 0x00000006 Used in slot 3 5 Total number of input bytes 32 Total number of output bytes 0 Number of submodules 1 Submodule ID 0x00000001 Subslot 0x0001 Number of in...

Страница 21: ...ID 0x00000001 Subslot 0x0001 Number of input bytes 0 Number of output bytes 64 5 4 Exchanging Data Acyclically Records The gateway component supports records This access type is useful for all events...

Страница 22: ...ardware revision 8 2 Major software version 10 2 Minor software version 12 4 Subversion revision Source code versioning 16 2 Fieldbus input length 18 2 Fieldbus output length 20 1 Bus state 20 2 Featu...

Страница 23: ...tten by the PROFINET controller via Record Read with Api 0 Slot 0 Subslot 1 Index 0xaff4 5 4 2 Diagnosis Alarm If communication to the partner gateway component is interrupted the gateway component fo...

Страница 24: ...e Web Server a Verbinden Sie das Gateway mit dem PC b Open your browser c Enter the IP address as a URL e g http 192 168 0 8 You can log in now Logging on to the Web Server You can log on to the web s...

Страница 25: ...k To access the FTP server you must create a network configuration For this example we will use these settings Network 192 168 1 0 24 IP address Windows PC 192 168 1 1 IP address GW ProfiNET TPS 1 192...

Страница 26: ...Gateway PROFINET IRT Slave 26 g Select Internet Protocol Version 4 with a double click h Set the desired IP address i Click on OK Integrated Servers...

Страница 27: ...Component to the PC Connect the Ethernet interface of the gateway component to the Ethernet interface on your PC A LAN cable is required a Download Proneta to your PC b Unpack the current version c Op...

Страница 28: ...Gateway PROFINET IRT Slave 28 Proneta is opened d Click on Settings e Click on the Network Adapter tab f Select the desired network interface Integrated Servers...

Страница 29: ...eway PROFINET IRT Slave 29 g Click on Home h Click on network analysis The network analysis is opened The network connection between Windows PC and the gate way component is displayed Integrated Serve...

Страница 30: ...Gateway PROFINET IRT Slave 30 i Select the gateway component by double clicking on it The configuration interface opens j Enter the network configuration here Integrated Servers...

Страница 31: ...Gateway PROFINET IRT Slave 31 k Click on Set The IP address is now set Integrated Servers...

Страница 32: ...m Enter ping and the IP address of the gateway component This allows you to check whether the configuration is correct Setting up FTP Server You have installed a program for data transfer We use File...

Страница 33: ...3 n Open FileZilla o Click on New server p Set the following parameters in the General tab IP address Select FTP protocol User name Admin Password 1701 q Click on the Advanced tab r Check the box Bypa...

Страница 34: ...Gateway PROFINET IRT Slave 34 s Click on Connect t Copy the KFU file to the gateway component Integrated Servers...

Страница 35: ...Gateway PROFINET IRT Slave 35 u Restart the gateway component Your firmware has been updated Integrated Servers...

Страница 36: ...Storage temperature 30 C 60 C Humidity 93 at 40 C Condensing Not allowed Protection class Control cabinet Housing Terminal area IP54 IP20 IP20 Assembly data DIN rail 35 x 7 5 mm Height 96 mm Depth 11...

Страница 37: ...Gateway PROFINET IRT Slave 37 Illustration 7 Side dimensions Illustration 8 Front dimensions Technical Data...

Страница 38: ...KUNBUS GmbH 38 Gateway PROFINET IRT Slave...

Страница 39: ...KUNBUS GmbH Gateway PROFINET IRT Slave 39...

Страница 40: ......

Отзывы: