Kullhaus alpha Q13L Скачать руководство пользователя страница 4

3

  SAFETY INSTRUCTION

• 

Read the operating instructions carefully before using the dehumidifier & keep it for future reference.

• 

To avoid electric shock, fire or injury, please read the user manual carefully before using the appliance and keep it for future 
reference.

• 

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental 
capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the 
appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user 
maintenance shall not be made by children without supervision.

• 

The unit is designed only for use with R-290 (propane) gas as the designated refrigerant.

•  THE REFRIGERANT LOOP IS SEALED. ONLY A QUALIFIED TECHNICIAN SHOULD ATTEMPT TO SERVICE!

• 

Do not discharge the refrigerant into the atmosphere.

• 

R-290 (propane) is flammable and heavier than air.

• 

It collects first in low areas but can be circulated by the fans.

• 

If propane gas is present or even suspected, do not allow untrained personnel to attempt to find the cause.

• 

The propane gas used in the unit has no odour.

• 

The lack of smell does not indicate a lack of escaped gas.

• 

If a leak is detected, immediately evacuate all persons from the store, ventilate the room and contact the local fire department 
to advise them that a propane leak has occurred.

• 

Do not let any persons back into the store until the qualified service technician has arrived and that technician advises that it 
is safe to return to the store.

• 

No open flames, cigarettes or other possible sources of ignition should be used inside or in the vicinity of the units.

• 

Component parts are designed for propane and non-incentive and non-sparking. Component parts shall only be replaced 
with identical repair parts.

• 

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in 
order to avoid a hazard.

• 

The appliance shall be disconnected from its power source during maintenance.

• 

Ensure the unit is far away from fire, inflammable, or explosive objects.

• 

Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture.

Содержание alpha Q13L

Страница 1: ...alpha Q13L Instruction Manual DEHUMIDIFIER Thank you for choosing Kullhaus Please read instructions before using the dehumidifier and keep it for future reference...

Страница 2: ...for Service and Repair Work 5 6 Product Description 7 Placement 7 Control Panel Description 8 Operating Instructions 9 10 Cleaning and Maintenance 11 Trouble Shooting 12 Display Error Codes 13 Techni...

Страница 3: ...nd tendered at a regional recycling centre and be processed in an ecological manner This unit uses a flammable refrigerant If refrigerant leaks and comes in contact with fire or heating part it will c...

Страница 4: ...ns If propane gas is present or even suspected do not allow untrained personnel to attempt to find the cause The propane gas used in the unit has no odour The lack of smell does not indicate a lack of...

Страница 5: ...ll ventilated area where the room size corresponds to the room area as specified for opera tion Warning on Refrigerant R290 Failure to abide by this warning could result in an explosion death injury a...

Страница 6: ...equipment being used is suitable for use with flammable refrigerants i e no sparking adequately sealed or intrinsically safe Presence of fire extinguisher If any hot work is to be conducted on the re...

Страница 7: ...a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently resistant...

Страница 8: ...ith the value on the nameplate power outlet needs to be grounded Do not use the device with power strip as they may overheat and cause a fire However if necessary use a good quality extension cord and...

Страница 9: ...Manual Button 3 Timer Button 4 Sleep Button 5 Sleep Mode Indicator 6 Timer Setting Indicator 7 Humidity Display 8 Defrosting Indicator 9 Tank Full Indicator CONTROL PANEL DESCRIPTION 1 2 9 8 3 4 6 5...

Страница 10: ...wer button once to turn on the unit By default it runs on Manual Dehumidifying Mode Press Power button once again to turn off the unit Humidity Setting Control Press Manual button once to enter Manual...

Страница 11: ...perly above phenomenon will appear also Automatic Defrost Feature The unit is equipped with an automatic defrost feature When room temperature drops to 4 C and below compressor shuts off and unit runs...

Страница 12: ...se a mild detergent if necessary 3 Rinse the pre filter in clean water and let it dry before reinserting it 4 Fit the filter frame back onto the unit Note DO NOT use the dehumidifier without the Air F...

Страница 13: ...clogged Clean the filter The ambient humidity level is lower than the target humidity level set Set the target humidity lower than ambient humidity Dehumidifier is blowing out warm air The dried air i...

Страница 14: ...atts 0 95A 27 C 60 Air Flow H 95 L 70 m h Fan speeds 2 Water Tank Capacity 2 3L Noise level H 39 L 35 dB A Operating Temperature 5 C 35 C Timer 1 24h Refrigerant Charge R290 0 045kg Weight 11 kg Dimen...

Страница 15: ...ered and date stamped purchase receipt 5 The warranty is not valid for Damages is caused by actions that deviate from those as described in the user s manual or by neglect Damages caused from interven...

Страница 16: ...EXPORT TECHNICAL SA 5 7 Kosti Palama Str 143 43 Athens Greece Tel 30 210 3236627 3233766 Fax 30 210 3247709 e mail info sanihellas gr www sanihellas gr SANI HELLAS IMPORT EXPORT TECHNICAL SA distribu...

Отзывы: