4.11.5.4
Stopping distances and stopping times, STOP 1, A3
Fig. 4-101: Stopping distances for STOP 1, axis 3
Fig. 4-102: Stopping times for STOP 1, axis 3
4.11.6
Stopping distances and times, KR 70 R2100 and KR 70 R2100 F
4.11.6.1
Stopping distances and stopping times, STOP 0, A1 to A3
The table shows the stopping distances and stopping times after a
STOP 0 (category 0 stop) is triggered. The values refer to the following
configuration:
• Extension l = 100%
• Program override POV = 100%
• Mass m = maximum load (rated load + supplementary load on arm)
Stopping distance
A1
37.62 °
A2
21.05 °
KR IONTEC
152/344 |
www.kuka.com
MA KR IONTEC V4 | Issued: 11.05.2021
Technical
data
Содержание IONTEC KR 20 R3100
Страница 14: ...KR IONTEC 14 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Introduction...
Страница 166: ...KR IONTEC 166 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Planning...
Страница 188: ...KR IONTEC 188 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Start up and recommissioning...
Страница 300: ...Fig 9 58 Wiring diagram axis A2_KS A1 A3 KR IONTEC 300 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Repair...
Страница 301: ...Fig 9 59 Wiring diagram axis A3_KS A1 A3 KR IONTEC MA KR IONTEC V4 Issued 11 05 2021 www kuka com 301 344 Repair...
Страница 302: ...Fig 9 60 Wiring diagram axis A4_KS A1 A3 KR IONTEC 302 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Repair...
Страница 303: ...Fig 9 61 Wiring diagram axis A5_KS A1 A3 KR IONTEC MA KR IONTEC V4 Issued 11 05 2021 www kuka com 303 344 Repair...
Страница 304: ...Fig 9 62 Wiring diagram axis A6_KS A1 A3 KR IONTEC 304 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Repair...
Страница 310: ...KR IONTEC 310 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Repair...
Страница 318: ...KR IONTEC 318 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Decommissioning storage and disposal...
Страница 340: ...KR IONTEC 340 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 KUKA Service...