Issued: 29.11.2012 Version: KR C4 Interbus 1.1 V2 en (PDF)
6 Configuration
6
Configuration
6.1
Overview
6.2
DIP switches on the master module
The DIP switches are on the top left-hand side of the master module.
KUKA default
: DIP 1 … 3 OFF
1 ... 3: Card
number
DIP switches 1 to 3 are used for setting the card number. If multiple Interbus
cards are used, a card number must be assigned to each one. This number is
used to identify the different cards in the system. The card number can be set
Step
Description
1
DIP switches of master module
(
>>>
6.2 "DIP switches on the master module" Page 21)
2
Only if INTERBUS slave present.
DIP switches of slave module
(
>>>
6.3 "DIP switches on the slave module" Page 22)
3
Configure the configuration file IBSPCI.XML.
(
>>>
6.4 "Configuring the file IBSPCI.XML" Page 24)
4
Configure INTERBUS with WorkVisual.
(
>>>
6.5 "Configuring the bus with WorkVisual" Page 28)
5
Map the inputs and outputs in WorkVisual.
6
Transfer the bus configuration from WorkVisual to the robot
controller.
Additional information about procedures in WorkVisual is contained in
the WorkVisual documentation.
Fig. 6-1: DIP switches on the master module
Содержание Interbus 1.1
Страница 8: ...8 65 Issued 29 11 2012 Version KR C4 Interbus 1 1 V2 en PDF Interbus 1 1...
Страница 12: ...12 65 Issued 29 11 2012 Version KR C4 Interbus 1 1 V2 en PDF Interbus 1 1...
Страница 20: ...20 65 Issued 29 11 2012 Version KR C4 Interbus 1 1 V2 en PDF Interbus 1 1...
Страница 62: ...62 65 Issued 29 11 2012 Version KR C4 Interbus 1 1 V2 en PDF Interbus 1 1...
Страница 64: ...64 65 Issued 29 11 2012 Version KR C4 Interbus 1 1 V2 en PDF Interbus 1 1...
Страница 65: ...65 65 Issued 29 11 2012 Version KR C4 Interbus 1 1 V2 en PDF Interbus 1 1...