KEA 350 P1 / KEA 350 RP-P1
Страница 1: ...Kuhse Power Solutions GmbH An der Kleinbahn 39 21423 Winsen Germany Fon 49 4171 798 0 Fax 49 4171 798 117 www kuhse de BA KEA 350 P1 KEA 350 RP P1_EN Version 03 USER MANUAL KEA 350 P1 KEA 350 RP P1 ...
Страница 2: ...Panel Access 7 3 1 1 Basic Navigation 7 3 1 2 The HOME Screen 11 4 Operation 13 4 1 Power ON 14 4 2 Change Operating Modes 15 4 2 1 Operating Mode STOP 15 4 2 2 Operating Mode MANUAL 17 4 2 3 Operating Mode AUTOMATIC 19 4 2 4 Operating Mode TEST 20 4 3 Restore Language Setting via HMI Buttons and Softkeys 21 1 Amendments 2019 10 16 Creation Twesten 2020 05 25 Layout adjustment Twesten Created Amen...
Страница 3: ...ply and D terminal 4 Relay outputs terminal 5 CAN bus interface connector CAN 2 6 RS 485 interface connector RS 485 1 7 CAN bus interface connector CAN 1 8 CAN bus interface connector CAN 3 9 USB interface connector 2 0 slave SERVICE port 10 ETHERNET interface connector RJ 45 LAN C 11 ETHERNET interface connector RJ 45 LAN B 12 ETHERNET interface connector RJ 45 LAN A The KEA 3X0 series are contro...
Страница 4: ...nal connectors are delivered with plug and jack B QR Code Link to configuration software and manual C and D with plastic housing KEA 350 P1 LT only C Clamp fastener installation material 4 x D Screw kit installation material 12 x E Printed QR Code sticker 2 x Configuration files and Technical Manual are available at the CD ROM and additionally on device internal memory Opening USB connection to th...
Страница 5: ...2 1 Terminal Allocation Fig 4 Terminals KEA 3X0 P1 LT plastic housing Fig 5 Terminals KEA 3X0 P1 sheet metal housing 2 2 Wiring Diagram The Protective Earth terminal 61 is not connected on the sheet metal housing Use the protective earth PE connector located at the bottom center of the sheet metal housing instead ...
Страница 6: ...50 P1 KEA 350 RP P1_EN Version 03 Datum 17 Sep 2020 Seite 6 von 21 Fig 6 Wiring diagram KEA 350 RP P1 KEA 350 P1 LT 1 Configurable by LogicsManager 2 Vnom 12 24 V SELV 3 Pin 61 Metal housing don t use Plastic housing with HMI display Earth ground ...
Страница 7: ...hapter for detailed description of the front panel with display and buttons Buttons can be disabled by ToolKit with parameter 12978 p 149 S 1010 Lock keypad 3 1 1 Basic Navigation Main screen After power up the control unit displays the main screen HOME screen Fig 7 The main screen can be divided into the following basic sections Fig 7 Main screen 1 Values 2 Status Messages 3 Alarm Messages 4 Sing...
Страница 8: ...ter 9 5 3 Status Messages on page 1049 Alarm messages 3 The alarm message section Fig 70 3 of the screen shows the last alarm message that is occurred and not yet acknowledged For a list of all alarm messages refer to Chapter 9 5 4 2 Alarm Messages on page 1054 Single line diagram 4 The single line diagram Fig 70 4 shows the current status of the engine and power circuit breakers This section is a...
Страница 9: ...elected value Confirm Input Confirm and store changed value Acknowledge Message Acknowledge Delete message event Open Breaker Open mains generator breaker MANUAL mode Close Breaker Close mains generator breaker MANUAL mode Code req Request a blink code for one error message from the ECU Repeated pressing of this softkey displays all stored error mes sages J1939 Special Screen Reset Reset the blink...
Страница 10: ...nding alarm condition is still present Alarm class A B C D E F present Symbol with indicates that an alarm of class A B C D E F is present Alarm class A B C D E F not present Symbol without indicates that an alarm of class A B C D E F is not present Setpoints Generator Power Indicates the generator power actual value Mains Power Indicates the mains power actual value Synchroscope Phase Angle Indic...
Страница 11: ...ay the single line diagram with without mains is select able via parameter 4129 p 149 Oneline diagram with mains Two customizable buttons enable selection of indications to display engine and auxiliary values full access via ToolKit name description cannot be changed via HMI Find menu Parameter Configure HMI Configure customer screen x Two display brightness levels can be switched by LogicsManager...
Страница 12: ... L3 Generator Mains Generator values as described above and additionally for Mains Voltage Frequency Current Power Power factor Generator Busbar Generator values as described above and additionally for Busbar Voltage Power Frequency Generator Engines Generator values as described above and additionally for Engine Engine speed rpm Oil pressure bar or psi Water temperature C or F Operating hours h B...
Страница 13: ...lected via AnalogManager definition of the parameters at Parameter Configure HMI Screen configuration Menu texts and symbols cannot be changed 4 Operation In operation the genset controller can be manually or remote controlled Front panel access is described in chapter 4 1 Front Panel Access on page 98 Access via ToolKit is described in chapter 4 2 6 View And Set Values In ToolKit on page 133 Acce...
Страница 14: ...SB device is not detected correctly Please unplug plug the USB connection after the KEA finished starting With power cycle of the KEA 3X0 the USB connection is lost Please unplug plug and or start USB connection again after the KEA finished starting starting plastic housing HMI version Power ON from zero power Buttons are illuminated Start up screen appears the red bar at the bottom monitors the d...
Страница 15: ...on page 315 for details Select Operation Mode Operation modes can be selected via front panel buttons plastic housing variant or Remote Panel RP 300 or VNC client HMI configuration plastic housing variant or Remote Panel RP 300 or VNC client remote settings via interfaces or ToolKit The following chapters describe the manually front panel access 4 2 1 Operating Mode STOP Usage Use the STOP button ...
Страница 16: ...e enabled The start request is ignored The start push buttons softkeys are disabled The engine generator monitoring remains activated exception all monitoring that is delayed by the engine speed If the operating mode STOP is selected while the engine was running the following applies Dependent on the current application mode a soft shut down will be executed Pressing the STOP button again opens th...
Страница 17: ...uttons Use the mode button MAN to activate operating mode MANUAL The MAN button is illuminated The breakers will open immediately without power reduction To open the breaker in a no load condition reduce the load manually in the setpoints screen Chapter 4 1 5 Specialized Menu Screens on page 107 Example for application mode A01 To start the engine Press the button I below the MAN button Success Th...
Страница 18: ...ew Function Status Symbol Available in application mode Start running engine Stop stand still engine Breaker open command is issued or a clo sure of the breaker is blocked No defined breaker state Open the GCB Close the GCB Open the GGB1 Close the GGB1 Open the MCB Close the MCB 1 The GGB can not be operated via softkey ...
Страница 19: ...or automatically by the control unit i e a mains failure The function of the KEA depends on the configuration of the unit and how the external signals are used Use the button AUTO to activate operating mode AUTOMATIC If mode change was successful the button AUTO is illuminated For a more detailed description of the start stop sequence of the engine and the associated parameters refer to Chapter 4 ...
Страница 20: ...y operating mode The idea is to test the genset TEST operating mode always starts the engine when changing into this mode independent on an AUTOMATIC start order Additionally the TEST operating mode supports the emergency and critical run as well if a mains failure occurs during the test run The operating mode TEST supports different sub modes so the operator can choose if the breakers shall be cl...
Страница 21: ... is on code level 0 so the instruction will work with each code level Fig 11 Front panel and display 1 Press button HOME once to return to the start screen 2 Press softkey 6 once to access the Parameter screen 3 Press softkey 3 once to access the Configure language clock screen 4 Press softkey 7 once to edit the language setting 5 Press softkeys 11 or 12 to select the desired language 6 Press soft...