MERGE MAXX 950
120
11. - Troubleshooting guide
KN233BGB_C
Merger
11. Troubleshooting guide
Problem
Cause
Remedy
Pneumatic braking system
Malfunction of the pneumatic
braking system.
Water in the circuit.
- Empty the circuit.
Air leak.
- Check condition and
sealing of the circuit
components.
Incorrect air pressure in the
air reservoir.
- Contact your Kuhn dealer
to service and repair the
brake system.
Incorrect air pressure in the
brake cylinders.