Spreading operation
B
158
AXIS-GENERAL
AXIS
20.1
AXIS
30.1 (W), AXIS 40.1 (W)
AXIS 50.1 W
10.
Check that there is a clearance between the spreading vanes and the outlet
by turning the spreading discs manually.
11.
Fasten the calibration test chute and adjustment lever to their normal posi-
tions on the solid fertiliser broadcaster.
B.7
Check mounting height
B.8
Setting the PTO speed
8.
Carefully position cap nut
(do not tilt).
9.
Tighten the nut manually
with
25 Nm
(hand-tight). Do
not
use the adjustment le-
ver.
Figure 11:
Screw on cap nuts
NOTICE
The cap nuts have an internal catching mechanism that prevents them from
coming loose. It should be felt when tightening the nut. Otherwise the cap nut is
worn and must be replaced.
NOTICE
Check with full hopper whether the preset mounting height is correct.
Take the mounting height setting values from the calibration chart.
The preset mounting height should not exceed the maximum allowed
mounting height.
„Preset the mounting height“ on page 46
.
NOTICE
Take the correct PTO speed from the calibration chart.