Parameter
setting
instructions
Kühla
Kühltechnik
&
Ladenbau
GmbH
AT1
‐
5BQ6E
‐
2KU
Parameter
list
Collection
of
all
parameters
relating
to
the
factory
settings
Parameter
Setting
range
Description
Setup
Kühla
1
°
C
/
2
°
C
/
°
F
Reading
scale
1
°
C
‐
50.SPH
°
Minimum
set
point
1
°
C
SPL...
+
120
°
Limit
value
15
°
C
SPL...SPH
°
Setpoint
7
°
REF
/
HEA
(HEA)
cooling
/
heating
(HEA)
REF
1.10.0
°
Switching
hysteresis
2
K
0.30
min
Compressor
break
3
min
0.30
min
Activation
time
RL1
fault
T1
10
min
0.30
min
Stop
time
RL1
fault
T1
5
min
0.30
min
Delay
compressor
stop
at
Door
open
/
DS
only
=
YES
‐‐‐
0.24
Defrost
frequency
/
24
h
3
/
24
h
‐
50..
+
120
°
Temperature
defrost
‐‐‐
1.120
min
Maximum
defrost
duration
30
min
OFF
/
ELE
/
GAS
Defrost
type
OFF
0.60
min
Display
when
defrost
5
NON
/
ABS
/
REL
Alarm
type
REL
‐
50..
+
120
°
Lower
alarm
threshold
‐‐‐
‐
50..
+
120
°
Upper
alarm
threshold
‐‐‐
‐
12.0°
Lower
alarm
differential
‐
4
K
0...
+
12
°
Upper
alarm
differential
+
8
K
0.120
min
Temperature
alarm
delay
90
min
0.30
min
Door
alarm
delay
0
min
0.52
Weeks
Message
condenser
cleaning
26
NO.
/
YES
Activate
stand
‐
by
YES
NO.
/
YES
Activate
the
door
switch
NO.
NON
/
0
‐
1
/
DEF
LGT
/
ALR
Modes
of
operation
AUX
output
0
‐
1
SN4
/
ST1
Sensor
selection
SN4
‐
12,
5...
+
12,
5
°
Measurement
value
correction
T1
0
°
C.
NO.
/
YES
Activation
T2
NO.
‐
12,
5...
+
12,
5
°
T2
measurement
value
correction
0
°
C.
1.30
min
Storage
interval
TLO
/
TLI
10
min
0.100
Display
slow
down
0
1.255
Bus
address
1