Parameter

 

setting

 

instructions

 

Kühla

 

Kühltechnik

 

&

 

Ladenbau

 

GmbH

 

AT1

5BQ6E

2KU

 

 
 
 
 

Parameter

 

list

 

 

Collection

 

of

 

all

 

parameters

 

relating

 

to

 

the

 

factory

 

settings

 

 

 

Parameter

 

Setting

 

range

 

Description

Setup

 

Kühla

 



 

1

 

°

 

C

 

/

 

2

 

°

 

C

 

/

 

°

 

F

 

Reading

 

scale

1

 

°

 

C

 



 

50.SPH

 

°

 

Minimum

 

set

 

point

1

 

°

 

C

 



 

SPL...

 

+

 

120

 

°

 

Limit

 

value

15

 

°

 

C

 



 

SPL...SPH

 

°

 

Setpoint

7

 

°

 



 

REF

 

/

 

HEA

 

(HEA)

 

cooling

 

/

 

heating

 

(HEA)

REF

 



 

1.10.0

 

°

 

Switching

 

hysteresis

2

 

K

 



 

0.30

 

min

 

Compressor

 

break

3

 

min

 



 

0.30

 

min

 

Activation

 

time

 

RL1

 

fault

 

T1

10

 

min

 



 

0.30

 

min

 

Stop

 

time

 

RL1

 

fault

 

T1

5

 

min

 



 

0.30

 

min

 

Delay

 

compressor

 

stop

 

at

Door

 

open

 

/

 

DS

 

only

 

=

 

YES

‐‐‐

 



 

0.24

 

Defrost

 

frequency

 

/

 

24

 

h

3

 

/

 

24

 

h

 



 

50..

 

+

 

120

 

°

 

Temperature

 

defrost

‐‐‐

 



 

1.120

 

min

 

Maximum

 

defrost

 

duration

30

 

min

 



 

OFF

 

/

 

ELE

 

/

 

GAS

 

Defrost

 

type

OFF

 



 

0.60

 

min

 

Display

 

when

 

defrost

5

 



 

NON

 

/

 

ABS

 

/

 

REL

 

Alarm

 

type

REL

 



 

50..

 

+

 

120

 

°

 

Lower

 

alarm

 

threshold

‐‐‐

 



 

50..

 

+

 

120

 

°

 

Upper

 

alarm

 

threshold

‐‐‐

 



 

12.0°

 

Lower

 

alarm

 

differential

4

 

K

 



 

0...

 

+

 

12

 

°

 

Upper

 

alarm

 

differential

+

 

8

 

K

 



 

0.120

 

min

 

Temperature

 

alarm

 

delay

90

 

min

 



 

0.30

 

min

 

Door

 

alarm

 

delay

0

 

min

 



 

0.52

 

Weeks

 

Message

 

condenser

 

cleaning

26

 



 

NO.

 

/

 

YES

 

Activate

 

stand

by

YES

 



 

NO.

 

/

 

YES

 

Activate

 

the

 

door

 

switch

NO.

 



 

NON

 

/

 

0

1

 

/

 

DEF

 

LGT

 

/

 

ALR

 

Modes

 

of

 

operation

 

AUX

 

output

0

1

 



 

SN4

 

/

 

ST1

 

Sensor

 

selection

SN4

 



 

12,

 

5...

 

+

 

12,

 

5

 

°

 

Measurement

 

value

 

correction

 

T1

0

 

°

 

C.

 



 

NO.

 

/

 

YES

 

Activation

 

T2

NO.

 



 

12,

 

5...

 

+

 

12,

 

5

 

°

 

T2

 

measurement

 

value

 

correction

0

 

°

 

C.

 



 

1.30

 

min

 

Storage

 

interval

 

TLO

 

/

 

TLI

10

 

min

 



 

0.100

 

Display

 

slow

 

down

0

 



 

1.255

 

Bus

 

address

1

 