Technical Manual
Absolute Multiturn Encoders
C
C
A
A
N
N
L
L
i
i
f
f
t
t
R.000.000
13-20 of 41
Format of an Emergency Message
Example of an over-temperature message:
Transfer Data
00
42
09
80
56
20
50
2E
[Errcode]
4200 Temperature threshold value of the sensor exceeded
[Error Register]
09 Error
Register
[ManufacturerSpecific1]
80
ICLG error register
[ManufacturerSpecific2]
56
ICLG instantaneous temperature
[ManufacturerSpecific3]
20
ICLG current threshold lower range
[ManufacturerSpecific4]
50
ICLG current threshold upper range
[ManufacturerSpecific5]
2E
ICLG versions register
Emergency Object Protocol
An "unconfirmed" Service message is defined
The behaviour in the case of an error is described in
Object 1029h Error Behaviour