![KUDOS pinnacle 8 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/kudos/pinnacle-8/pinnacle-8_installation-instructions-manual_2009297003.webp)
FIT WALLPOSTS TO WALLS
1
FIT BOTTOM TRIM TO SIDE PANEL
2
FIT SIDE PANEL GLASS
3
Position
wallpost for door
(with fitted seal to outside),
22mm
in from front edge of tray, as shown above.
Using spirit level to ensure wallpost is vertical, mark through
three slotted holes onto wall surface and remove wallpost.
Using 7mm drill bit, drill holes in walls to centre of slotted marks
made and fit rawlplugs supplied or fixings suitable for the
construction of the wall.
Fix wallpost to wall using 3x no.8's x 30mm long screws
provided. Tighten all screws using pozi-head screwdriver.
TIP
Insert screw heads into the wizard tool supplied to aid insertion of
screws into wall plugs.
Repeat for
wallpost for side panel
, positioning this
10mm
from
edge of tray, as shown.
Apply a bead of silicone sealant around bottom & centre holes made
in wall before fixing wallpost to wall.
22mm
Position of
wallpost for door
when fitting on showertray
10mm
Position of
wallpost for side
panel
when fitting on
showertray
OUTSIDE
OUTSIDE
Fitted seal to outside
Fitted seal to outside
Take note of label on glass panel -
‘This surface to outside’
-
this will determine which is the bottom edge for your installation.
Peel off a small length of the bottom trim adhesive tape and
apply to bottom of glass panel 15mm from the end shown.
Continue along length of trim, peeling away the tape as you go,
until the full trim length is adhered to the panel.
clear pvc bottom
protective trim
glass
panel
bottom trim
to be fitted
centrally
TIP
Use small upturned edges on bottom trim against chamfered glass
edges to ensure trim is fitted centrally.
side panel glass
glass notches at this side
CAREFULLY fit glass panel into slot in wallpost, ensuring panel
is parallel to tray edge.
8mm
glass notches
at this side
Ensure outer edge of side panel is vertical, as shown, using
spirit level. If necessary, use small wedge supplied underneath
glass panel to aid levelling - insert this from the inside.
Position outer edge of side panel glass
8mm
back from the
OUTER face of adjacent wallpost, as shown.
Ensure factory drawn lines on side panel glass do not
extend beyond front face of wallpost.
edge of side panel glass
to OUTER face of wallpost
1st wedge
self-
adhesive
tape
DETAIL
15mm
factory drawn
lines on glass
top & bottom