background image

1

Issue 01 JAN.20

Tools Required

Pozi-head Screwdriver

3mm Allen Key - supplied

Cutting Pliers

Clear Silicone Sealant

7mm Masonry Drill Bit

Spirit Level

Tape Measure

Drill (Battery or Mains)

Pencil

Flat-head Screwdriver

INSTALLATION INSTRUCTIONS - CENTREFOLD CORNER

Please read these instructions throughout before installing as incorrect fitting will invalidate the guarantee.

If you are unsure about these instructions please contact Kudos Shower Products 01539 564040.

HEALTH & SAFETY WARNING

DUE TO THE WEIGHT & SIZE OF THE GLASS PANEL(s) A MINIMUM OF TWO PERSONS ARE REQUIRED

TO MOVE AND INSTALL THIS ENCLOSURE

For the wall post and fixings use only warm soapy water and damp cloth/ sponge 
on a regular basis. After cleaning please rinse with clean water to remove any 
residue. 

Do not use abrasive scouring powders, chemicals or aerosol cleaners - these may 

result in damage to the surfaces, in particular, the plated component parts.

The glass panels are pre-treated with Life Shield on the inside surfaces only.

Whilst this makes cleaning the glass easier and helps prevent the build up of 
harmful lime-scale and soap deposits, the glass still needs to be maintained on a 

regular basis. We recommend the use of a detergent and aroma free glass cleaner 
(A 50/50 mix of white vinegar and water works well).

DO NOT use strong detergents, abrasive cleaners or abrasive scrubbing 

equipment for cleaning, these can damage the coating.

DO use a squeegee to remove remaining droplets of water from glass after 
showering, any build up of residue can be removed easily using an appropriate 

cleaner and agitation from soft cleaning equipment.

Cleaning - General

Kudos LifeShield Glass Treatment

Important

Check appearance of all product - any defects must be reported to Kudos Shower 

Products before assembly/installation. Claims for imperfections will only be 
accepted prior to assembly/installation.

Any claims made under the terms of the Lifetime Guarantee must be reported to 

Kudos within 21 days of the fault occurring.

Check the enclosure adjustment sizes are suitable for your installation.

Use care when drilling into the walls to avoid hidden pipes or electric cables.

Stage 2

silicone sealant

Stage 1

Shower Tray

Ensure the top of shower tray is 

LEVEL in ALL directions.

Once the tray is installed but 

before the wall tiles are fitted, any 

gap between the tray and the walls 

must be filled with silicone sealant 
flush with the top of the tray.

Once the walls have been tiled but 
before the enclosure is installed, 
the tiles must be silicone sealed to 
the tray all of the way around in 

one continuous bead.

Failure to follow these 
instructions will result in 
leakage problems.

THESE INSTRUCTIONS ARE TO BE LEFT

WITH THE CONSUMER

Содержание Pinnacle 8 CENTREFOLD 800

Страница 1: ...mix of white vinegar and water works well DO NOT use strong detergents abrasive cleaners or abrasive scrubbing equipment for cleaning these can damage the coating DO use a squeegee to remove remaining droplets of water from glass after showering any build up of residue can be removed easily using an appropriate cleaner and agitation from soft cleaning equipment Cleaning General Kudos LifeShield Gl...

Страница 2: ... DOOR PACK A 800 P8CF80P1 P8CF80P2 770 to 790 900 P8CF90P1 P8CF90P2 870 to 890 1000 P8CF100P1 P8CF100P2 970 to 990 PRODUCT PACK CODES DIMENSIONS mm CENTRE FOLD SIDE PANEL PACK B 800 P8CF2SP80 770 to 790 900 P8CF2SP90 870 to 890 ENCLOSURE HEIGHT 2000mm 26mm A 26mm A LEFT HAND INSTALLATION RIGHT HAND INSTALLATION ...

Страница 3: ...lpost is vertical 4 Position side panel wall post 16mm in from front edge of the tray as shown Repeat the above steps Insert screw heads into the wizard tool supplied to help locate screws into wall plugs Then tighten with pozi head screwdriver 1 Take note of label on glass This surface to outside this will determine which is the bottom edge of your installation 2a For 800 Side Panel Unit acquire ...

Страница 4: ...ls Step 4 Fit Corner Joint Seal 1 Acquire the PlexRF 018 06 from the Side Panel Pack From starting at the bottom press this over the glass edge ensuring that it is fully seated over the entire length Position as shown If tight lubricate corner seal and glass edges with a damp clean cloth to ease fitment the water will evaporate over a short period Do not use silicone spray or any other substance o...

Страница 5: ...ram below 2 Secure the rail with M144 02 AG using No 6x19 CSK Apply to the end you intend the door to pivot hinge from Secure the opposite side with SF BIF CLMP 998 using M6x30 CSK Step 11 Fit Top Rail to Fixed Panels 1 Acquire the remaining last rail Outer extrusion to be on the outside of the glass Like step 7 line up the 2 holes on the rail with 2 slot holes at the top of the glass Ensure flang...

Страница 6: ...ottom hinge and fully tighten Open the door and discard the spacer block 1 Acquire SF BIF SLID 998 from the installation pack and disassemble Insert the top slide on the closing side of the door into the rail by tilting the slide and lowering the rectangular slide into the track of the rail Tilt the slide and offer it into the rail as shown 2 Now push up and into the Slide will run smoothly in the...

Страница 7: ...nclosure will not leak under normal showering use ie when the shower head is in it s normal showering position N B Using the shower head to clean rinse down the enclosure does not constitute normal showering use Step 20 Fitting the Door Seals 1 There are two longer seals 2 x 1940mm and one shorter 1 x 1926mm similar to the diagram shown The longer seals fit the the fixed glass panels either side o...

Отзывы: