PERIODIC SERVICE
48
ENGLISH
B
Checking Coolant Level
To avoid serious injury or death:
A
Do not remove the radiator cap when the
engine is hot. Then loosen cap slightly to the
stop to relieve any excess pressure before
removing cap completely.
Check the coolant level daily both the radiator and the
recovery tank before starting engine.
1. Remove the radiator cap and check to see that the
coolant level is just below the fill port.
2. Check to see that the coolant level is between the
"FULL" and "LOW" marks of recovery tank.
3. When the coolant level drops due to evaporation, add
water only up to just below the fill port of the radiator
and the full level of the recovery tank.
In case of leakage, add anti-freeze and water in the
specified mixing ratio up to the full level.
(See "Flushing Cooling System and Changing
Coolant" in "EVERY 2000 HOURS or EVERY 2
YEARS" in "PERIODIC SERVICE" section.)
A
If the radiator cap has to be removed, follow the
caution above and securely retighten the cap.
A
Use clean, distilled water and anti-freeze to fill the
radiator and the recovery tank.
A
If water should leak, consult your local KUBOTA
Dealer.
B
Lubricating All Grease Fittings
To avoid serious injury or death:
A
Be sure to stop the engine and remove the key
before greasing.
A
Be sure to reinstall the removed cover after
greasing.
Grease the following location.
(1) Recovery tank
(2) Radiator cap
(A) "FULL"
(B) "LOW"
(1) Mower universal joint
(2) Grease nipple
(A) Apply grease to the spline with
the brush.
Содержание ZD326
Страница 14: ...SAFE OPERATION 6 ENGLISH 7 PICTORIAL SAFETY LABELS ...
Страница 15: ... 7 SAFE OPERATION ENGLISH ...
Страница 16: ...SAFE OPERATION 8 ENGLISH ...
Страница 17: ... 9 SAFE OPERATION ENGLISH ...
Страница 18: ...SAFE OPERATION 10 ENGLISH ...
Страница 20: ......
Страница 22: ...SERVICING OF MACHINE 2 ENGLISH 1 Mower identification plate 2 Mower serial No 1 ROPS serial No ...