MAINTENANCE
70
ENGLISH
EVERY 1500 HOURS
B
Checking Fuel Injection Nozzle (Injection
Pressure)
Consult your local KUBOTA Dealer for this service.
EVERY 2000 HOURS or EVERY 2 YEARS
Be sure to do the following service once every 2000 hours
or every 2 years whichever comes faster.
B
Flushing Cooling System and Changing
Coolant
To avoid serious injury or death:
A
Do not remove the radiator cap when the
engine is hot. Then loosen cap slightly to the
stop to relieve any excess pressure before
removing cap completely.
1. Stop the engine and let cool down.
2. To drain the coolant, open the radiator drain valve and
remove the radiator drain plug and remove radiator
cap. The radiator cap must be removed to completely
drain the coolant.
3. After all coolant is drained, close the drain valve and
install the drain plug.
4. Fill with clean water and cooling system cleaner.
5. Follow directions of the cleaner instruction.
6. After flushing, fill with clean water and anti-freeze until
the coolant level is just below the fill port on the
radiator.
Install the radiator cap securely.
7. Fill with coolant up to the "FULL" mark on the recovery
tank.
Set the direction of the recovery tank cap outlet at left
front (45 ). Set the bottom tip of the hose between
front side of radiator hose and inner side of the frame.
(This will prevent the hose from pulling down and open
the recovery tank cap.)
8. Start and operate the engine for a few minutes.
9. Stop the engine and let cool.
10.Check coolant level of recovery tank, add coolant if
necessary, and install the drain plug.
(1) Secondary element
(1) Recovery tank
(2) Radiator cap
(3) Drain plug
(4) Recovery tank cap
(5) Radiator hose
(6) Frame
(A) "FULL"
(B) "LOW"
(C) 45
Содержание ZD1211
Страница 16: ...SAFE OPERATION 8 ENGLISH 7 DANGER WARNING AND CAUTION LABELS ...
Страница 17: ... 9 SAFE OPERATION ENGLISH ...
Страница 18: ...SAFE OPERATION 10 ENGLISH ...
Страница 20: ......
Страница 22: ...SERVICING OF MACHINE 2 ENGLISH 1 Mower identification plate 2 Mower serial No ...