Service - 74
SK1050 Operator’s Manual
Startup/10 Hour
Check Hydraulic Fluid Level
Check hydraulic fluid level at startup and every 10
hours. Maintain fluid level at halfway point on
sight glass (2), when engine is off, cylinders are
fully retracted, and fluid is cool. If low, add THF at
fill (1).
Check Brake Operation
Check brake operation at startup and every 10
hours or more often when conditions warrant..
•
Ensure parking brake pin (shown) moves
freely allowing brake to be engaged and
disengaged.
•
Clean mud and debris from area around pin.
Check Lug Nut Torque
Check lug nut torque at 10 hours, 50 hours and
every 200 hours thereafter. Tighten to 88-95 ft•lb
(108-129 N•m), as needed.
IMPORTANT:
Engine must be running to
check brake operation.
t35om013w.eps
1
2
t35om014w.eps
t35om036w.eps
Содержание SK1050
Страница 1: ...SK1050 Operator s Manual 053 2963 Issue 2 0 Original Instruction ...
Страница 11: ...Contents 10 SK1050 Operator s Manual Appendix additional information about Ditch Witch equipment 103 ...
Страница 21: ...Safety 20 SK1050 Operator s Manual Machine Safety Alerts ...
Страница 41: ...Controls 40 SK1050 Operator s Manual Attachment Plate ...
Страница 52: ...SK1050 Operator s Manual Drive 51 Drive Chapter Contents Start Unit 52 Drive 52 Shut Down 55 ...
Страница 57: ...Drive 56 SK1050 Operator s Manual Shut Down ...
Страница 65: ...Transport 64 SK1050 Operator s Manual Retrieve ...
Страница 97: ...Specifications 96 SK1050 Operator s Manual SK1050 Power Specifications ...
Страница 100: ......
Страница 101: ......
Страница 102: ...SK1050 Operator s Manual Service Record 101 Service Record Service Performed Date Hours ...
Страница 103: ...Service Record 102 SK1050 Operator s Manual Service Performed Date Hours ...
Страница 104: ...SK1050 Operator s Manual Appendix 103 Appendix Chapter Contents Engine Diagnostic Codes ...