10
PERIODIC SERVICE
PERIODIC SERVICE
SERVICE AS REQUIRED
B
Replacing Fuse
The tractor electrical system is protected from potential
damage by fuses.
A blown fuse indicates that there is an overload or short
somewhere in the electrical system.
If any of the fuses should blow, replace with a new one of
the same capacity.
A
Before replacing a blown fuse, determine why the fuse
blew and make any necessary repairs. Failure to
follow this procedure may result in serious damage to
the tractor electrical system. Refer to the
"TROUBLESHOOTING" section of this manual or your
local KUBOTA Dealer for specific information dealing
with electrical problems.
B
Replacing Light Bulb
FUSE
No.
CAPACITY
(A)
Protected circuit
(1)
15
Work Light (R)
(2)
15
Work Light (L)
(3)
5
Alternator, Engine, Glow Plug
(4)
5
Meter Panel, OPC
(5)
10
Turn Signal
(6)
15
Auxiliary Power
(7)
5
Meter (Back Up)
(8)
20
Head Light, Tail Lamp
(9)
15
Flasher (Hazard)
(10)
5
Starter Relay
(11)
10
Horn
(12)
50
Charge, Glow Plug
(13)
30
Fuel Cut Solenoid, Work Light
(14)
40
Key switch, Head Light, Hazard
Light
Capacity
Head light
12 V, 55 / 60 W (H4)
Hazard and turn signal light
(Round)
12 V, 23 W
Hazard and turn signal light
12 V, 21 W
Brake stop light / Tail light
12 V, 21 / 5 W