Zero and Span Adjustment Changes

 

3

 

Zero and Span Adjustment Changes

 

Use the following steps to adjust zero and span changes.

1.

Remove the four screws that secure the metal backplate covering the
CPU board.

2.

With power off, press the slide switch located on the left hand side of
CPU board down to span position (see Figure 2 on page 4).

3.

Switch power on by pressing the on/off key. Be certain the scale is
level.

4.

The number displayed is the internal dead load count.

5.

Press the zero key to bring the display to 0.

6.

Place a calibration test weight (see table below) on platform and wait
for the indicator to become stable.

7.

When stable, press and hold set key, then press the select key. The
display should read as follows:

8.

Remove the test weight from the platform. The display should return
to a zero reading. If not, repeat steps 4, 5, 6, and 7 above.

9.

Turn power off.

10. Turn power back on and press zero key to check adjustments.

11. When span adjustment is complete, turn power off and return slide

switch upward for normal operation.

12. Replace the metal backplate over CPU board.

 

Scale Capacity

Recommended Calibration Weight

70 lb

60 lb

150 lb

150 lb

300 lb

300 lb

 

Table 1-1. Recommended Calibration Weight

 

Scale Capacity

Displayed Reading

70 lb

30,000 +/– Grad

150 lb

37,500 +/– Grad

300 lb

30,000 +/– Grad

 

Table 1-2. Displayed Readings

Содержание KA-10 Series

Страница 1: ...Kubota KA 10 Series Scale Conversion to Counting Scale 16851 ...

Страница 2: ...rved Printed in the United States of America Specifications subject to change without notice October 1999 Contents Introduction 1 Converting to Counting Scale 2 Zero and Span Adjustment Changes 3 Dead Load Adjustment Changes 4 Kubota KA 10 Limited Warranty 5 ...

Страница 3: ...p a large zero error may be present After switching power on if the full display appears but then changes to a bar this indicates a large zero error This is often caused by jarring of the load cell during shipping The scale can easily be restored to normal function by following the steps below Calibrating for Zero Use the following steps to calibrate for zero 1 Switch power off 2 Press and hold bo...

Страница 4: ...egal For Trade 8 Turn indicator off Locate J 2 and remove jumper and place on J 1 9 Turn indicator back on and press select unit key to check operation 10 Turn the indicator off Screw the back plate on making sure that ground wires are in correct position unless a zero and span adjustment or a dead load adjustment need to be done 11 Close indicator cover Note When the counting scale is enabled the...

Страница 5: ...elow on platform and wait for the indicator to become stable 7 When stable press and hold set key then press the select key The display should read as follows 8 Remove the test weight from the platform The display should return to a zero reading If not repeat steps 4 5 6 and 7 above 9 Turn power off 10 Turn power back on and press zero key to check adjustments 11 When span adjustment is complete t...

Страница 6: ...e 2 The switch is up for normal weighing down for calibration and zero set 2 With the indicator off press the slide switch down to the span position 3 With added dead load on platform turn power on Press the zero button 4 When dead load adjustment is complete turn power off and return slide switch upward for normal operation 5 Replace cover metal back plate cover over the CPU board Figure 2 Locati...

Страница 7: ...Such equipment has not been modiÞed altered or changed by any person other than RLWS or its duly authorized repair agents RLWS will have a reasonable time to repair or replace the defective equipment Buyer is responsible for shipping charges both ways In no event will RLWS be responsible for travel time or on location repairs including assembly or disassembly of equipment nor will RLWS be liable f...

Отзывы: