![Kubota CAGE 2500 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/kubota/cage-2500/cage-2500_operator-and-parts-manual_2008761015.webp)
15
Operating instructions – Soap injection / Stopping the machine
Injecting soap
The pressure washer will only draw soap with the BLACK
SOAPING nozzle tip is attached.
WHITE, GREEN, AND YELLOW NOZZLE WILL NOT DRAW SOAP.
1. Remove the high pressure nozzle at the wand outlet and
replace it by the black soap nozzle (figure 11).
2. Insert the soap filter and hose (O on figure 12) in a liquid
soap container.
3. Depress the gun trigger. Water and soap mix will take
30 seconds to reach the nozzle and flow out.
4. Once soap application is finished, remove the soap
nozzle and install a high pressure nozzle to rinse (yellow,
green or white). Soap will flow out for 30 seconds and
then stop.
• If corrosive products have been injected, rinse injector by
injecting water for a couple of minutes.
Stopping the Machine
1. If the machine has been used for soap injecting, install
a high pressure yellow, green or white nozzle at wand
outlet.
2. Depress the gun trigger until water flows out limpid and
regularly, and at a temperature of less than 100°F (40°C).
3. Release the gun trigger.
4. Move the throttle lever (H on figure 13) completely to
the right.
5. Let the engine idle for a couple of seconds.
6. Turn off the engine switch (I on figure 14).
7. Turn right the fuel valve (F on figure 13) to close.
8. Close the water supply valve.
9. Depress the gun trigger to release pressure from the
system.
10. Disconnect the water supply hose.
11. Make sure that all nozzles, tool, gun and wand are stored
in their proper place.
12. Make sure that all safety equipment is stored in its
proper place.
Figure 12
Figure 11
Figure 13
Figure 14
Soaper
Black
IMPORTANT:
H
G
F
J
I
O