background image

english

9

4.12 End of programming

5. Connection

1 10 – 30 V DC
2 GND
3 GND
4 MPI
5 0 (4) – 20 mA
6 Analog GND
7 0 (2) – 10 V DC

6. Technical data

Display:

5 digits - 7-segment LED’s, height 8 mm

Measuring ranges:

0..10 V DC
2..10 V DC
0..20 mA
4..20 mA

Resolution:

14 bits

Accuracy:

0.1 % ± 1 digit at an ambient 
temperature of 20 °C

Zero adjustment:

automatic

Temperature drift:

<70ppm/K

Measuring speed:

1 s-1

Current measuring:

Voltage drop:
max. 2,0 V at 20 mA
Current limitation: 50 mA

Voltage measurement:

Input resistance:

>1 M

Mains hum suppression:

Digital filtering 50 Hz or 60 Hz, programmable

Supply voltage:

10..30 V DC

galvanically isolated

The programming routine
is performed once again.
The values input can be
checked and modified.

The programming routine
is finished and the values
entered are taken as the
new parameter values.
The device is then ready to
operate.

Maximum consumption:

50 mA 

Ambient temperature:

-10°C .. +50°C

Storage temperature:

-25°C .. +70°C

Data recording:

via EEPROM (capacity : 1x106 recording cycles 
or 10 years)

Weight:

appr. 50g

Protection:

IP 65 (on the front)

EMC:

EN 61 000-4-2 ; EN 55011 class B ;
EN 61 000-6-2

Error messages:

Err 0*

Error/defect in A/D-part

Err 3*

Error/defect EEPROM 

Err 4**

Analogue input overflow

Err 5*

Error/defect EEPROM. Device 
not calibrated

*  Please send the device back for checking

** Please check input signal and programming

Cleaning:

The front side of the device is to be cleaned only with a
wet cloth.

7. Delivery specification

• Digital display
• Panel mounting clip
• Bezel for screw mount, panel cut-out 50 x 25 mm
• Bezel for clip mount, panel cut-out 50 x 25 mm
• Sealing
• 1 sheet with self-adhesive symbols

Содержание 6.530.012.300

Страница 1: ...ignal mit Anschluß 2 oder 3 zu verbinden SPANNUNGSEINGANG Anschluß 7 Analoger Spannungsmeßeingang Die Signalleitung mit dem analogen Signal ist hier anzuschließen Bei Ver polung erscheint im Display Err4 Achtung Zur Vermeidung von Störsignalen die von der Spannungsversorgung herrühren ist dieser Ein gang galvanisch getrennt Für eine Messung ist daher die negativere Meßsignalleitung mit dem analoge...

Страница 2: ...stellung b Werkseinstellung maximale Einstellung Je nach gewähltem Meßbereich 4 20 mA oder 0 10 V wird a oder b durchlaufen Wählen Sie mit der linken Taste die Dekade und geben Sie mit der rechten Taste den Meßwert ein der dem Minimalwert entsprechen soll 4 4 Anzeigewert bei minimalem Eingangssignal Sie können dem niedrigsten Eingangssignal für die An zeige einen Wert zwischen 19999 und 99999 zuor...

Страница 3: ...uf den Summierer Gesamtskalierung Factor x Skalierung 4 9 Skalierung Mit der Skalierung können Sie den Anzeigebereich für den Summierer erweitern bzw für eine sehr feine Ein stellung verringern Im Beispiel 8 2 auf Seite 5 kann der Vorratstank mehr als 100000 l aufnehmen Mit einer Skalierung von 0 01 können Sie die Summe in Hektoliter anzeigen Da der Scaler Multiplikator nur auf die Summe wirkt wir...

Страница 4: ...endet und alle eingestell ten Werte werden als neue Parameter übernommen Das Gerät ist anschließend betriebsbereit Max Stromaufnahme 50 mA Lagertemperatur 25 C 70 C Umgebungstemperatur 10 C 50 C Datensicherung EEPROM 1 Mio Speicherzyklen oder 10 Jahre Gewicht ca 50 g Schutzart IP 65 von vorne EMV Störabstrahlung EN 61 000 4 2 EN 55 011 Klasse B Störfestigkeit EN 61 000 6 2 Fehlermeldungen Err 0 Fe...

Страница 5: ...n Sie für den Summierer keine Dezimalstelle und da dies noch nicht ausreicht erhöhen Sie den Anzeigebe reich mit dem Scaler 0 01 um zwei Stellen so daß die addierte Menge in Hektoliter angezeigt wird Drücken Sie die rechte Taste um zwischen der Anzeige des aktuellen Wertes und der Summe umzuschalten Mit verschiedenen Faktoren können Sie die addierte Menge auch in anderen Einheiten anzeigen z B mit...

Страница 6: ...easuring loop and the supply voltage is not required connect 2 or 3 and this input 0V measurement signal by means of a bridge VOLTAGE INPUT Connect 7 Analog voltage measuring input Connect to pin 7 the analogue signal wire In case of a connection error the message Err4 is displayed Attention This input is electrically isolated to avoid interference from the supply voltage Thus for the measurement ...

Страница 7: ...not added a Factory setting Maximum setting b Factory setting Maximum setting According to the selected measuring range 4 20 mA or 2 10 V the device asks for programming of a or b With the left key select the decade then use the right key to determine the measurement value that is to cor respond to the minimum value 4 4 Value displayed for the minimum input signal A display value between 19999 and...

Страница 8: ...define the corresponding factor multiplier Note the factor and the scale only affect the adding counter Total scale Factor x Scale 4 9 Scale The scale allows extending the display range of the adding counter or reducing it for a very fine adjust ment Select the decade with the left key then use the the right key to define a factor between 0 0001 and 9 9999 In Example 8 2 on page10 the tank has a c...

Страница 9: ...modified The programming routine is finished and the values entered are taken as the new parameter values The device is then ready to operate Maximum consumption 50 mA Ambient temperature 10 C 50 C Storage temperature 25 C 70 C Data recording via EEPROM capacity 1x106 recording cycles or 10 years Weight appr 50g Protection IP 65 on the front EMC EN 61 000 4 2 EN 55011 class B EN 61 000 6 2 Error m...

Страница 10: ...onding factory set ting Allocate the display value 0 to the lowest input signal lo display and the display value 180 to the highest input signal hi display This way the device displays the instantaneous speed in km h Set the adding counter decimal point dp tot according to the maximum planned test time for example for a 24 hour test at maximum speed four digits before the decimal point will be suf...

Страница 11: ...li mentation effectuer un pont entre la broche 2 ou 3 et cette entrée signal de mesure 0V Notice de mise en service de l afficheur digital à entrées analogiques CODIX 530 Codification de commande 6 530 012 300 ENTREE EN TENSION Raccordement 7 Entrée analogique de mesure de tension Connecter icile conducteur du signal analogique Dans le cas d une erreur de branchement le message Err4 est affiché 3 ...

Страница 12: ...sente un défaut Les va leurs affichées ne sont pas totalisées a Réglage d usine Réglage maximum b Réglage d usine Réglage maximum L appareil demande la programmation de a ou de b en fonction de la plage de mesure sélectionnée 4 20 mA ou 2 10 V Sélectionner à l aide du bouton pous soir de gauche la décade puis à l aide du bouton poussoir de droite déterminer la valeur de mesure devant correspondre ...

Страница 13: ...9 4 8 Facteur Grâce au facteur la valeur d affichage peut être adap tée de manière optimale à la mesure à effectuer Si par exemple il faut afficher la valeur instantanée dans une petite unité comme le gramme mais le résultat du tota lisateur en kilogrammes ou en tonnes il suffit de déter miner le facteur multiplicateur correspondant Nota le facteur et l échelle n affectent que le totalisa teur Ech...

Страница 14: ...paramètres L appareil est alors prêt à fonctionner 6 Caractéristiques techniques Affichage 5 chiffres LED à 7 segments hauteur 8 mm Plages de mesure 0 10 VDC 2 10 VDC 0 20 mA 4 20 mA Résolution 14 bits Précision 0 1 1 chiffre à température ambiante de 20 C Ajuste de zéro automatique Dérive due à la température 70 ppm K Vitesse de mesure 1 Hz Vitesse de mesure 0 5 2 mesures sec Mesure en courant Ch...

Страница 15: ...levée qui est affichée 8 2 Mesure de débit avec totalisation Il faut afficher en alternance le débit instantané et la quantité totalisée Le capteur de mesure à caractéristiques linéaires dans le cas de capteurs non linéaires il faut intercaler des éléments de linéarisation délivre 4 mA à l arrêt et 20 mA au débit maximum ce qui correspond dans cet ex emple à 90 l min Sélectionner sous Range la pla...

Страница 16: ... instantanée en km h ainsi que le temps total de fonctionnement d un moteur au banc d essai Le capteur de mesure délivre 4 mA à l arrêt et 20 mA à pleine vitesse ce qui correspond dans cet exemple à 180 km h Sélectionner sous Range la plage de mesure de 4 à 20 mA et pour les signaux d entrée maximum hi act et minimum lo act le réglage d usine corre spondant Affecter au signal d entrée le plus bas ...

Отзывы: