Main work
(All SX
‑
F models)
–
Check the battery voltage.
» Battery voltage: < 9 V
–
Do not charge the battery.
–
Replace the battery and dispose of the old battery properly.
» If the specifications have been met:
Battery voltage:
≥
9 V
–
Recharge the battery.
–
Connect the battery charger to the battery. Switch on the battery charger.
Battery charger (58429074000)
You can also use the battery charger to test the open-circuit voltage and start
potential of the battery, and to test the alternator. With this device, you cannot
overcharge the battery. The charging time may be longer at low temperatures.
Info
Never remove lid
.
–
Switch off the battery charger after charging and disconnect from the battery.
Guideline
The charging current, charging voltage, and charging time must not be
exceeded.
Maximum loading voltage
14.4 V
Maximum loading current
3.0 A
Charge the battery regularly when the
motorcycle is not in use
6 months
S00863-10
(XC
‑
F US)
–
Check the battery voltage.
» Battery voltage: < 9 V
–
Do not charge the battery.
–
Replace the battery and dispose of the old battery properly.
» If the specifications have been met:
Battery voltage:
≥
9 V
–
Recharge the battery.
–
Connect the battery charger to the battery. Switch on the battery charger.
Battery charger (58429074000)
You can also use the battery charger to test the open-circuit voltage and start
potential of the battery, and to test the alternator. With this device, you cannot
overcharge the battery. The charging time may be longer at low temperatures.
Info
Never remove lid
.
–
Switch off the battery charger after charging and disconnect from the battery.
Guideline
The charging current, charging voltage, and charging time must not be
exceeded.
Maximum loading voltage
14.4 V
Maximum loading current
3.0 A
Short-term maximum loading current
10.0 A
Charge the battery regularly when the
motorcycle is not in use
6 months
Finishing work
–
Install the battery.
–
Mount the seat. (