Configuration

Description

MAC Address

The MAC address factory configured for the switch
It can not be changed in any cases.

S/W Version

The firmware version currently running

H/W Version

The hardware version currently operating

Active IP Address

Currently used IP address for the switch management

Active Subnet Mask

Currently used subnet mask for IP address for the switch management

Active Gateway

Currently used gateway IP address for the switch management

DHCP Server

Current IP address of the DHCP server

Lease Time Left

The time left for the lease IP address currently used

DHCP Enabled

Use DHCP to get dynamic IP address configuration for the switch

Fallback IP Address

IP address used when DHCP mode is not enabled

Fallback Subnet Mask

Subnet mask for IP address used when DHCP mode is not enabled

Fallback Gateway

Default gateway IP address used when DHCP mode is not enabled

WDT

Enable WDT (Watch Dog Timer)

Management VLAN

Set management VLAN information

- VID

VLAN ID configured for web management to the switch

- CFI

CFI value for web reply packets from the switch

- User priority

Priority value for web reply packets from the switch

Name *

Set the system name for this switch unit

Password

Set new password

SNMP enabled

Enable SNMP agent

SNMP Trap destination

The IP address of the SNMP trap manager

SNMP Read community The community allowed for the SNMP [

get

] message

SNMP Write community The community allowed for the SNMP [

set

] message

SNMP Trap community

The community used for the SNMP trap messages sent by the switch

[Apply]

Click to apply the configuration change

[Refresh]

Click to refresh current configuration

Note:

1. It is suggested to give each switch unit a system name as an alternative unique identifica-

tion beside IP address.

2. Setting change of DHCP mode takes effective in next bootup.

3. A watch dog timer (WDT) is a hardware timing device that triggers a system reset if the

system firmware, due to some fault condition, such as a hang, neglects to regularly service
the watch dog timer . The intention is to bring the system back from the hung state into
normal operation. The timer is set to 1.72 seconds in this switch.

Содержание KGS-612F

Страница 1: ...1 KGS 612F Web Smart 6 Port Gigabit Ethernet Switch with Fiber Connectivity User s Manual DOC 150331...

Страница 2: ...rves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For m...

Страница 3: ...terface cables and AC power cord if any must be used in order to comply with the emission limits CISPR A COMPLIANCE This device complies with EMC directive of the European Community and meets or excee...

Страница 4: ...s 16 3 1Abbreviation 16 3 2 QoS Function 17 3 2 1 Packet Priority Classification 18 3 2 2 Priority Class Queues 18 3 2 3 Egress Service Policy 18 3 3 VLAN Function 19 3 3 1 VLAN Operation 19 3 3 2 Ing...

Страница 5: ...ttings 37 4 6 3 4 VLANGroups 39 4 6 4 Important Notes for VLAN Configuration 40 4 7Aggregation 41 4 8 LACP 42 4 9 RSTP 43 4 10 802 1X Configuration 44 4 10 1 802 1X Re authentication Parameters 46 4 1...

Страница 6: ...mini GBIC SFP port can also be installed with an optional SFP optical fiber transceiver to support one Gigabit fiber connection when needed Web Management The switch is embedded with an Http server wh...

Страница 7: ...toring and control function Supports port based and 802 1Q Tag based VLAN Provides QoS function Provides link aggregation port trunking function with LACP support Provides port mirroring function Prov...

Страница 8: ...00Mbps Duplex support Full Half duplex Network cable Cat 5 UTP Combo Port with 10 100 1000 RJ 45 and 1000Mbps Mini GBIC SFP Copper interface Compliance IEEE 802 3 10Base T IEEE 802 3u 100Base TX IEEE...

Страница 9: ...Eye safety IEC 825 compliant Switch Functions MAC Addresses Table 8K entries Forwarding filtering Non blocking full wire speed Switching technology Store and forward Maximum packet length 1526 bytes...

Страница 10: ...protection control settings Port statistic LACP status RSTP status Reboot restore factory default update firmware DC Power Input Interfaces DC Jack D 6 3mm D 2 0mm Operating Input Voltages 7 5VDC 5 P...

Страница 11: ...he power cable extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not operate corre...

Страница 12: ...e matching the commercial power voltage in your area The AC Power Adapter Specifications AC input power AC power voltage of your area options Rated AC120V 60Hz DC7 5V 1 2A Rated AC230V 50Hz DC7 5V 1 2...

Страница 13: ...to detect the twisted pair signals and adapts itself to form a valid MDI to MDI X connection with the remote connected device automatically No matter a straight through cable or crossover cable is con...

Страница 14: ...r is seated securely in the slot place the bail in lock position Connecting Fiber Cables LC connectors are commonly equipped on most SFP transceiver modules Identify TX and RX connector before making...

Страница 15: ...2 10 Configuring IP Address and Password for the Switch The switch is shipped with the following factory default settings for software management Default IP address of the switch 192 168 0 2 255 255...

Страница 16: ...d Ethernet frame with no VLAN Tag field Priority tagged packet An IEEE 802 1Q packet which VID filed value is zero VID 0 VLAN Tagged packet An IEEE 802 1Q packet which VID filed value is not zero VID...

Страница 17: ...n to guide the packet forwarding in four priority classes The versatile classification methods can meet most of the application needs The following figure illustrates the QoS operation flow when a pac...

Страница 18: ...to an egress port 3 2 2 Priority Class Queues Each egress port in the switch is equipped with four priority class egress queues to store the packets for transmission A packet is stored into the class...

Страница 19: ...ing and packet tag removal The related Ingress port settings are 3 3 2 1 802 1Q Tag Aware Per port setting Tag aware 802 1Q Tag Aware mode is used The switch examines the tag content of every received...

Страница 20: ...n Ingress port default tag is used it is copied as packet associated Packet Tag Information for VLAN classification The PVID is used as index to one VLAN group in VLAN group table 3 3 4 Packet Tag Inf...

Страница 21: ...opped Refer to section 3 2 4 for details about how the Packet Tag information is generated The member ports specified in the matched VLAN group are the admitted egress port range for the packet The pa...

Страница 22: ...oups VLAN Group Settings per group VID Member Ports Source Port Check Egress Settings Insert Tag Untagging Specific VID Untagged VID VLAN range supported 1 4095 eight VLANs at the same time PVID VID U...

Страница 23: ...pplicant At this point in the process the port on the switch is connected from a physical standpoint however the 802 1X process has not authorized the port and no frames are passed from the port on th...

Страница 24: ...d enter the IP address of the switch unit to which you want to connect The IP address is used as URL for the browser software to search the device URL http xxx xxx xxx xxx Factory default IP address 1...

Страница 25: ...ing Port mirroring related configuration QoS Quality of Service related configuration Storm Control Packet Storm protection control configuration Monitoring Statistics Overview List simple statistics...

Страница 26: ...26 4 4 System...

Страница 27: ...on VID VLAN ID configured for web management to the switch CFI CFI value for web reply packets from the switch User priority Priority value for web reply packets from the switch Name Set the system na...

Страница 28: ...s is not zero The switch web http server only accepts tagged management packets matched Management VLAN VID and replies tagged packets with tag composed of Management VLAN VID CFI and User Priority se...

Страница 29: ...10 Full Disable 10M Full 100 Half Disable 100M Half 100 Full Disable 100M Full 1000 Full Enable 1000M Full Force 1000 Full Disable 1000M Full Flow Control Set port flow control function v set to enabl...

Страница 30: ...ce SONET compliance information of the transceiver GbE Compliance Gigabit Ethernet compliance information of the transceiver Vendor Name The vendor name of the transceiver Vendor OUI The vendor OUI of...

Страница 31: ...reely with no VLAN limitation Port based VLAN Mode Simple configuration for 2 port based VLAN groups Port based VLAN ISP Mode Simple configuration for 5 port based VLAN groups Advance VLAN Mode Full V...

Страница 32: ...change Refresh Click to refresh current configuration Back Click to go back to upper menu Operation in this mode 1 The member ports of two groups are allowed to overlap 2 The member ports in same grou...

Страница 33: ...sed VLAN groups are configured as follows auto matically Group 1 member Port 1 Port 6 Group 2 member Port 2 Port 6 Group 3 member Port 3 Port 6 Group 4 member Port 4 Port 6 Group 5 member Port 5 Port...

Страница 34: ...ion Ingress Default Tag Click to configure per port Ingress Default Tag settings Ingress Settings Click to configure per port ingress settings Egress Settings Click to configure per port egress settin...

Страница 35: ...D is used as index for VLAN classification VLAN group table lookup in one of the following conditions 1 Ingress port Tag Aware setting Tag ignore 2 Ingress port Tag Aware setting Tag aware and the rec...

Страница 36: ...ists Enable set to activate tag removal for VLAN tagged packets Disable set to disable tag removal function Drop Untag Drop all untagged packets and priority tagged packets Enable drop untagged packet...

Страница 37: ...VLAN classification VLAN table lookup The following table lists the index used Ingress Tag Aware setting Received packet type Tag ignore Tag aware Untagged PVID PVID Priority tagged VID 0 PVID PVID VL...

Страница 38: ...is function Untagged VID VID for Untagging Specific VID setting 1 4095 decimal 12 bit VID value Apply Click to apply the configuration change Refresh Click to refresh current configuration Back Click...

Страница 39: ...or the packets belong to the VLAN Port 1 6 click to select Source Port Check Check whether the ingress port is the member port of the VLAN Enable set to enable this check the packet is dropped if ingr...

Страница 40: ...group are configured with same VLAN configuration and are in same VLAN group 3 Double Tagged in Advanced VLAN Mode For a received packet Ingress port Keep Tag setting and Egress port Insert Tag settin...

Страница 41: ...o switches using more than one physical links It can increase the connection bandwidth between two switches The switch supports up to four trunk groups and the number of member ports belonging to one...

Страница 42: ...n same LACP link aggregate Value 1 255 Auto key value is assigned by the system Apply Click to apply the configuration change Refresh Click to refresh current configuration Notes 1 This configuration...

Страница 43: ...long a bridge should send this message to other bridge to tell I am alive Max Age When the switch is the root bridge the whole LAN will apply this setting as their maximum age time Forward Delay This...

Страница 44: ...listening and learning state because the edge ports cannot create bridging loops in the network Port Path Cost Specifies the path cost of the port that switch uses to determine which port are the forw...

Страница 45: ...he port is forced to be in authorized state Force Unauthorized the port is forced to be in unauthorized state Port State Port 802 1X state 802 1X Disabled the port is in 802 1X disabled state Link Dow...

Страница 46: ...l ports Reauthentication Period The period of time after which the connected radius clients must be re authenticated unit second Value 1 3600 EAPtimeout The period of time the switch waits for a suppl...

Страница 47: ...rt The port is forwarded all packets received on the mirrored ports Mirror Source Select the ports which will be mirrored all received packets to the mirror port Apply Click to apply the configuration...

Страница 48: ...s are disabled It is also used as default priority class for the received packet when both 802 1p and DSCP classifi cation failed in classification Class 3 Class 0 priority class 802 1p Mapping Click...

Страница 49: ...y class Mapped priority class for tag m on Port n Class 3 Class 0 Apply Click to apply the configuration change Refresh Click to refresh current configuration Back Click to go back to upper menu Every...

Страница 50: ...user defined DSCP value Class 3 Class 0 All others The other DSCP values not in the seven user defined values are assigned a default priority class Class 3 Class 0 Apply Click to apply the configurati...

Страница 51: ...5 3 1 1 Weighted ratio priority Class 3 2 1 0 1 1 1 1 weighted ratio 1 1 1 1 Apply Click to apply the configuration change Refresh Click to refresh current configuration Back Click to go back to uppe...

Страница 52: ...port Flooded Unicast Rate The rate limit of the flooded unicast packets transmitted on a port The flooded unicast packets are those unicast packets whose destination address is not learned in the MAC...

Страница 53: ...rames transmitted on the port Rx Bytes Total of bytes received on the port Rx Frames Total of packet frames received on the port Tx Errors Total of error packet frames transmitted on the port Rx Error...

Страница 54: ...4 4 15 Detailed Statistics Button Description Port Click to display the detailed statistics of Port Clear Click to reset all statistic counters Refresh Click to refresh the displayed statistic counter...

Страница 55: ...rtner Learning the port is learning by RSTP Forwarding the port is link up and forwarding frames Forwarding the port is link up and forwarding frames and the is the port number of LACP link partner Pa...

Страница 56: ...ber Protocol Active yes the port is link up and in LACP operation no the port is link down or not in LACP operation Partner Port Number The port number of the remote link partner Operation Port Key Th...

Страница 57: ...al BPDU from designated ports among bridges It decides how long a bridge should send this message to other bridge to tell I am alive 1 10 seconds Max Age When the switch is root bridge the whole LAN u...

Страница 58: ...ort may transition to the forwarding state BPDU data is still received in blocking state Listening The switch processes BPDUs and awaits possible new information that would cause it to return to the b...

Страница 59: ...ping commands generated Time Out in secs The time out for a reply in seconds Apply Start the ping command Status The command status Received replies The number of replies received by the system Reques...

Страница 60: ...and Management VLAN configuration 4 21 Update Firmware This menu is used to perform in band firmware switch software upgrade Enter the path and file name of new firmware image file for uploading Confi...

Страница 61: ...otocol SNMP RFC 1907 Management Information Base for Version 2 of the Simple Network Management Protocol SNMPv2 RFC 1213 Management Information Base for Network Manage ment of TCP IP based internets M...

Страница 62: ...SNMPTrap destination 0 0 0 0 SNMP Read community public SNMPWrite community private SNMPTrap community public Ports Configuration Enable Jumbo Frames Not select disabled Mode Auto for all ports Flow...

Страница 63: ...mber Ports None VLAN Group 2 Source Port Check Disable VLAN Group 3 VID 3 VLAN Group 3 Member Ports None VLAN Group 3 Source Port Check Disable VLAN Group 4 VID 4 VLAN Group 4 Member Ports None VLAN G...

Страница 64: ...elay 15 Force Version Normal 802 1X Configuration Mode Disabled RADIUS IP 0 0 0 0 RADIUS UDP Port 1812 RADIUS Secret None Admin State Force Authorized for all ports Reauthentication Enabled No Reauthe...

Страница 65: ...Port 6 tag 6 Class 3 Port 1 Port 6 tag 7 Class 3 QoS DSCP Mapping DSCP 1 Priority 0 Class 0 DSCP 2 Priority 0 Class 0 DSCP 3 Priority 0 Class 0 DSCP 4 Priority 0 Class 0 DSCP 5 Priority 0 Class 0 DSC...

Страница 66: ...l others DSCP Class 0 QoS Service Policy Port 1 Strict priority Port 2 Strict priority Port 3 Strict priority Port 4 Strict priority Port 5 Strict priority Port 6 Strict priority Storm Control Configu...

Отзывы: