1.1 Specifications

Twisted-Pair Interface
Compliance

IEEE 802.3ab 1000BASE-T

Connector

Shielded RJ-45 jack

Pin assignments

Auto-crossover for MDI and MDI-X

Data speed

1000Mbps

Duplex mode

Auto-negotiation for half-duplex or full-duplex

Cable type

4-pair Category 5 UTP

Supported cable length 100 meters

Fiber Optic Interface
Compliance

IEEE 802.3z 1000BASE-SX or LX

Connector

Duplex SC

Data speed

1000Mbps

Duplex mode

Forced full-duplex or auto-negotiation (by Auto SW)

Auto  SW

Auto-negotiation Enable/Disable switch

Cable types

Multimode (MM) - 50/125, 62.5/125
Single mode (SM) - 8.7/125, 9/125, 10/125

Optical

Class 1 FDA and IEC-825 laser safety compliant.

General Information
Frame Types Supported

IEEE 802.3 Std. 64Bytes ~ 1518Bytes frames
VLAN tagged frames ( plus 4 bytes tag)

DC Input power

+5V 1.5A min. (Operating range +5V +/-10%)

Power Consumption

4 watts max. ( 0.8A max. @+5V)

Dimension

H 25mm x W 96m x D 101mm

Housing

Enclosed metal with no fan

Operating Temperature

-10

o

C ~ 40

o

C (cold start 0

o

C)

Storage Temperature

-20

o

C ~ 70

o

C

Relative Humidity

0% ~ 70%

Содержание KC-210TF-LXC

Страница 1: ...1000BASE T to 1000BASE SX LX Media Converters KC 210TF SXC KC 210TF SXC O KC 210TF LXC KC 210TF LXC O KC 210TF LXC30 O KC 210TF LXC40 KC 210TF LXC80 P N 750 0158 002 DOC 050727 KC210 Installation Gui...

Страница 2: ...including the interference that may cause undesired operation CE NOTICE Marking by the symbol indicates compliance of this equipment to the EMC directive of the European Community Such marking is ind...

Страница 3: ...e Auto MDI MDI X crossover configuration and receiving polarity error correction on twisted pair interface Supporting low cost multimode fiber and single mode fiber cable when long reach connection is...

Страница 4: ...uplex mode Forcedfull duplexorauto negotiation byAutoSW Auto SW Auto negotiation Enable Disable switch Cable types Multimode MM 50 125 62 5 125 Singlemode SM 8 7 125 9 125 10 125 Optical Class1FDAandI...

Страница 5: ...rity correction for UTP connection Pin Assignments Pin MDI MDI X 1 BI_DA BI_DB 2 BI_DA BI_DB 3 BI_DB BI_DA 4 BI_DC BI_DD 5 BI_DC BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_DC Functions of 1000BASE X...

Страница 6: ...Sensitivity 210TF SXC SX 850nm 9 5 4 dBm 12 5dBm max 210TF SXC O SX 850nm 9 5 4 dBm 18dBm max 210TF LXC LX 1310nm 9 5 3 dBm 14 4dBm min 210TF LXC O LX 1310nm 9 3 dBm 21dBm min 210TF LXC30 O LX 1310nm...

Страница 7: ...status On TP Link up Off TP Link down TP FDX UTP duplex status On TP full duplex Off TP half duplex TP RX UTP Rx status On TP Receiver in operation Off TP no receiving operation TP TX UTP Tx status On...

Страница 8: ...which is used to supply the DC power for the unit should have the AC voltage matching the commercial power voltage in your area The specifications of the AC power adapter are AC input power AC power...

Страница 9: ...ecting to auto negotiation device and non auto negotiation device For proper communication the UTP connections on both ends must be in same configuration either 1000M full duplex or 1000M half duplex...

Отзывы: