6.2 Login to the System Unit
When browser software connects to the system unit successfully, aLogin screen is provided for you to login to the device as follows:
Login
Username : AdminFactory default Password : 123
Страница 1: ...1 Modular Media Converter Center System KC 3000 KC 1800 and Slide in 10 100 Media Converter Modules Slide in Gigabit Media Converter Modules Operation Manual DOC 040521 KC1800 KC3000 P N 720 0007 001...
Страница 2: ...rves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For m...
Страница 3: ...interface cables and AC power cord if any must be used in order to comply with the emission limits CISPR A COMPLIANCE This device complies with EMC directive of the European Community and meets or exc...
Страница 4: ...Console Management 29 3 4 Setup for In band Management 31 4 Console and Telnet Operation 32 4 1 IP Menu 36 4 2 SNMP Menu 37 4 3 View System Status 38 4 4 View Converter Slots Status 39 4 5 Restore Def...
Страница 5: ...6 6 Slot Icon Operations 65 7 Fast Ethernet Media Converter Modules 68 7 1 Specifications 70 7 2 Fiber Optic Specifications 71 7 3 Configuration Switch Settings for TP Interface 71 7 4 Making Single...
Страница 6: ...orkmediaconvertermodules Awiderangeofmediamodulesareavail abledependingonyourvarietyofnetworkcablingenvironment Theseoptional mediaconvertermodulesincludeUTPtomultimodeorsinglemodefibercablefor Ethern...
Страница 7: ...e modular system power module Provides high availability and maintainability Visible system status and failure LED indication Audio buzzer for fan failure indication Supports in band Telnet SNMP and w...
Страница 8: ...8mm 328mm 328mm Weight no MC modules 8 2Kg 8 0Kg 7 7Kg 7 5Kg Common Specifications Chassis withstand static load 60Kg Vibration Vibration 1 X Y Z 16 7Hz 4mm 1 hour Vibration 2 X Y Z 10 20Hz 1 3mm 20mi...
Страница 9: ...otection Safety UL1950 CSA22 2 950 TUV EN60950 Insulation Resistance 10M Ohm DC500V Dielectric withstands 1500VAC 10mA 1min Cooling 12V DC Fan DC Power Chassis Module Specifications Dimension 169 2mm...
Страница 10: ...and 3 Installation method Plug in from system front panel Mis insertion protection Yes CPU RISC based ARM7 RAM size 1M bytes Flash size 512K bytes System interface Connector DIN type connector Consol...
Страница 11: ...ubnet mask of the system Set and monitor Default gateway IP address Set and monitor SNMP name information Set and monitor SNMP location information Set and monitor SNMP contact information Set and mon...
Страница 12: ...roduct package contains The system unit One power cord One 19 inch rack mounting kit Operation Manual 2 2 System Units The figure below illustrates managed model KC 3000 series The figure below illust...
Страница 13: ...13 The following figure shows the model equipped with AC power chassis The following figure shows the model equipped with DC power chassis...
Страница 14: ...ne alarm buzzer for power or fan failure Management Module serves as a management agent to monitor system status and add on converter modules for in band and out of band man agement requests AC System...
Страница 15: ...n System power in normal condition Off System power failure FanFailureIndicator RedLED On Cooling fan in normal condition Off Cooling fan failure Alarm Buzzer Beep Beep when system power failure or fa...
Страница 16: ...facilitates the following functions Direct out of band management via RS 232 console port SNMP agent to serve in band management via SNMP protocol Telnet console in band management via TCP IP protoco...
Страница 17: ...otiation 10 100BASE TX LAN port and provides a shielded RJ 45 jack with MDI definition This port must connect to your TCP IP network for all in band management operations LEDIndicators LED Color State...
Страница 18: ...wer chassis are illustrated as fol lows AC System Power Chassis Specifications AC power switch System power on off switch AC power receptacle IEC320 type receptacle Input voltage rating 100 240VAC Inp...
Страница 19: ...ations Input power switch System power on off switch Input power receptacle Terminal connector screw type Input voltage rating 48VDC Input voltage range 36 75VDC Output power 150W The connection defin...
Страница 20: ...ever note that this removal only can be performed by a well trained technical person For safety reason before removing the power chassis make sure The system power switch is turned off The power cord...
Страница 21: ...it make sure The system power switch is turned off The power cord is disconnected from the power chassis To insert the power chassis hold the handle and push it into system unit until it is seated in...
Страница 22: ...media converter modules And KC 18000 un managed unit provides eighteen media converter module slots A converter module can be inserted into an available slot or removed from a slot anytime even when s...
Страница 23: ...l it is seated in slot properly Screw it onto system unit securely before making any cable connection To remove a converter module from slot disconnect all cable connec tions on the module first and u...
Страница 24: ...24 The following figure illustrates an example of a media converter module For more information about the converter slide in module refer to Chap ter 7...
Страница 25: ...ack Mounting One rack mounting kit is supplied in the product package It includes two bracketsand bracketscrewsforinstallingthesystemunitintoa19 inchrack Mount both brackets onto the system unit as sh...
Страница 26: ...26 Install the system unit into a 19 inch rack as shown below...
Страница 27: ...nection over an RS 232 cable Telnet software over TCP IP network SNMP manager software over TCP IP network Web browser software from Internet or Intranet over TCP IP network ManagementInterface RS 232...
Страница 28: ...m network or out of band requests from di rectly connected console 3 2 Protocols Supported Protocols Name Reference IPv4 IP version4 RFC791 TCP Transmission Control Protocol RFC793 UDP User Datagram P...
Страница 29: ...le Any PC running Windows 95 98 or NT can be used as a console via COM port Windows Hyper Terminal program is an ideal and the most popular software for such console terminal operations To setup conso...
Страница 30: ...t your terminal software Factory default settings of the Console port Baud rate 38400 N 8 1 0 Flow control disabled 4 Turn the system power on 5 Press Enter key several times in your terminal software...
Страница 31: ...t time for the installa tion 2 Find a proper straight through Category 5 UTP cable maximal length 100 meters for the connection 3 Connect one end of the UTP cable to the UTP port on SNMP module and co...
Страница 32: ...tor password for access control Update system software Reboot warm start the system remotely ManagementObjects Objects Modify Monitor Password for access control Y System CPU memory flash software ver...
Страница 33: ...System LOADER Checksum O K System IMAGE Checksum O K System DATA Checksum O K Waiting Copy Rom to Sdram System Power On Self Test ARM Reg R W Test Success System EEPROM Checksum O K Get parameter O K...
Страница 34: ...into DOS window and invoke Telnet command telnet xxx xxx xxx xxx to connect to the system unit The specified xxx xxx xxx xxx is the IP ad dress of the system unit A welcome message and login prompt ar...
Страница 35: ...Value 6 Security Manager 7 Update Firmware 8 Reboot System 9 Exit Please Select 0 9 Enter Esc to abort INET After prompt type a number followed by Enter key for selecting an operation item to perform...
Страница 36: ...teway IP xxx xxx xxx xxx 192 168 0 1 replacing gateway IP addr 0 nnn nnn nnn nnn with 192 168 0 1 Do you want to Change IP setting Y N Y Please reboot system and use new IP to connection it IPAddress...
Страница 37: ...s are Name Logic name for the system 16 characters Location Location where the system is installed 16 characters Contact Contact person regarding the system 16 characters Community SNMP communities to...
Страница 38: ...ollows Power status good Fan status good CPU status Cpu Type ARM7 Flash Size 512K Sdram Size 2M Bytes Software version 1 xx Power status indicates the power condition of the system Fan status indicate...
Страница 39: ...ull Up 07 A TX 100M Full Up 07 B FX 100M Full Up 08 A TX 100M Full Up 08 B FX 100M Full Up 09 A TX 100M Full Up 09 B FX 100M Full Up 10 A TX 100M Full Up 10 B FX 100M Full Up 11 A TX 100M Full Up 11 B...
Страница 40: ...f the module in slot B Lower port of the module in slot Media N A No module is installed in slot TX 10 100BASE TX port 1000BASE T port FX 100BASE FX port 1000BASE SX LX port Speed N A No module is ins...
Страница 41: ...23 Name null Location null Contact null SNMP Communities No 1 Community name public No 1 Access right Read only No 2 Community name null No 2 Access right N A No 3 Community name null No 3 Access righ...
Страница 42: ...login user name and password The steps are Display current user name Current username admin Current password Press Esc to abort Changeusernameandpassword Change username admin xxxxxx Enter password 1...
Страница 43: ...FTP operation one TFTP server is required and installed in the network to where this system connects and new firmware file image bin must be placed in the TFTP server The following information are req...
Страница 44: ...t download new image Y N Y Download image and please wait Confirmtoupdatesystemflashmemory Download new image complete do you want to update flash Y N Y Update flash and please wait Update flash compl...
Страница 45: ...ager software with graphical user interface The following figure illustrates an example model The system unit serves as an SNMP agent and provides the capabilities that allows network administrators v...
Страница 46: ...ed Contact Contact person regarding the system Community SNMP communities to which the system belongs and access right to the system read only or read write Trap hosts IP addresses of trap hosts to wh...
Страница 47: ...Entry 1 slotIndex 1 Y Slot ID 4 19 slotIndexDescription 2 Y Slot4 Slot19 slotModuleDescription 3 Y slotModuleType 4 Y sotModuleStatus_PortA_Media 5 Y Port A media type slotModuleStatus_PortA_LineSpeed...
Страница 48: ...ery System fan recovery from failure Slot Port A link Slot module Port A link down or up Slot Port B link Slot module Port B link down or up The binding information together with a trap is TrapName Va...
Страница 49: ...r later Set IP Address for the System Unit Before the system can be managed from a web browser software make sure a unique IP address is configured to the system Refer to Chapter 4 for how to set IP a...
Страница 50: ...Login to the System Unit When browser software connects to the system unit successfully a Login screen is provided for you to login to the device as follows Login Username Admin Factory default Passw...
Страница 51: ...is performed In addition to the device image the screen supports the following func tions on the right side 1 Home home page and device image 2 Converter Status view all slot status 3 System Status v...
Страница 52: ...ter modules can be identified by the color as follows Black 10 100 Fast Ethernet media converter modules Black purple 1000M Gigabit Ethernet media converter modules Click Converter Status to view all...
Страница 53: ...odule Port A Upper port of the module in slot B Lower port of the module in slot Media TX 10 100BASE TX port 1000BASE T port FX 100BASE FX port 1000BASE SX LX port Link Green Link up Red Link down Spe...
Страница 54: ...Number slot number where the status belongs to Power Status system power condition Fan Status system cooling fan CPU type CPU model equipped in management module RAM size Memorysizeequippedinmanagemen...
Страница 55: ...related settings 2 Console Port Information View RS 232 console configuration 3 Security Manager Change login user name and password 4 Image Refresh Time Set refresh time interval of the image 5 Updat...
Страница 56: ...Unique IP address designated to this system Subnet Mask ThesubnetmaskoftheIPaddressspecifiedabove Gateway The IP address of the default gateway router Click Update Settings to make new settings effect...
Страница 57: ...57 Click SNMP Entries button to set SNMP settings SNMP Entries System options Name Logic name for the system Location Location where the system is installed Contact Contactpersonregardingthesystem...
Страница 58: ...ystembelongs Access right Accessrightassociatedwiththecommunityname Click RO or RW to set access right for Read Only or Read Write Click Add button to add one new community into the community list Cli...
Страница 59: ...ssued Community The trap community to which the system belongs Enable Fan Trap EnabletrapforFanfailureevents Enable Power Trap Enabletrapforpowerfailureevents Enable Link Change Trap Enable trap for a...
Страница 60: ...60 6 5 2 Console Port Information This screen displays configuration of RS 232 console port...
Страница 61: ...61 6 5 3 Security Manager Security Manager allows you to change login user name and password Click Apply to make the changes effective...
Страница 62: ...image is updated periodically to present the latest status The default time interval of refreshing the image is 20 seconds It can be changed by clicking any of the time buttons displayed This is a run...
Страница 63: ...operation one TFTP server is required and installed in the network to where this system con nects and new firmware file image bin must be placed in the TFTP server Set IP address for the TFTP server f...
Страница 64: ...t System Reboot System allows you to reboot the system unit remotely Starting this command will make your current http connection lost You must rebuild the connection to perform any management operati...
Страница 65: ...ns In addition to the menu supported you may click the following image icons to show specific status Click slot 1 LED module on the system image shown on screen Power Status system power condition Fan...
Страница 66: ...to view system status CPU type CPU model equipped in management module RAM size Memorysizeequippedinmanagementmodule Flash size Flashmemoryequippedinmanagementmodule Software version Software version...
Страница 67: ...system Slot 4 slot 19 are for media converter module Port A Upper port of the module in slot B Lower port of the module in slot Media TX TP port 10 100BASE TX or 1000BASE T FX Fiber port 100BASE FX o...
Страница 68: ...ed packets High performance switching engine that performs forwarding and filtering at full wire speed Built in flow control mechanism to prevent heavy data congestion and degrading system performance...
Страница 69: ...ch provides 2 SC connectors All available models are similar except the fiber transceiver equipped The figure shows the some important compo nents as follows Twisted Pair Interface TP Port Fiber Inter...
Страница 70: ...lass1FDAandIEC 825compliant Data Speed 100Mbps Duplex Mode Full duplex Cable Types Multimode MM 50 125 62 5 125 mm Singlemode SM 8 7 125 9 125 10 125mm GeneralInformation Forwarding Filtering 10Mbps 1...
Страница 71: ...ch Settings for TP Interface The configuration switch SW1 located on the module is used for config uring the TP interface as follows SW1 Setting Function SW1 1 On Enable auto negotiation function Off...
Страница 72: ...strate two connection examples 7 5 LED Indications The module provides five green LEDs to indicate the following status LED Function State Interpretation PWR Power status On The power is on Off The po...
Страница 73: ...timal configuration connecting to an auto negotiation capable device Auto MDI MDI X crossover configuration and receiving polarity error correction on twisted pair interface Supporting low cost multim...
Страница 74: ...h provides 2 SC connectors All available models are similar except the fiber transceiver equipped The figure shows the some important compo nents as follows Twisted Pair Interface TP Port Fiber Interf...
Страница 75: ...face Compliance IEEE802 3z1000BASE SXorLX Connector DuplexSC Data speed 1000Mbps Duplex mode Forcedfull duplexorauto negotiation byAutoSW Auto SW Auto negotiation Enable Disable switch Cable types Mul...
Страница 76: ...nterface Full data rate of 1000Mbps for full duplex operation Configuration Jumper JP1 is used to enable or disable auto negotia tion function as follows NON AUTO Disable auto negotiation function and...
Страница 77: ...KC 3000 LXC MM 62 5 125mm 550 meters MM 50 125mm 550 meters SM 9 125mm 10Km KC 3000 LXC40 SM 9 125mm 40Km Remark MM Multimode SM Single mode 8 4 LED Indicators Name Status State Interpretation PWR Pow...