Страница 1: ... 1 KTGC 221 Managed 10Gigabit Ethernet Media Converter Installation Guide DOC 200526A ...
Страница 2: ...rves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact United States KTI Networks Inc P O BOX 631008 Houston Texas 77263 1008 Phone 713 2663891 Fax 713 2663893 E mail kti ktinet com URL http www ktinet com International Fax 886 2 2...
Страница 3: ... case the user will be required to correct the interference at his own expense NOTICE 1 The changes or modifications not expressively approved by the party responsible for compliance could void the user s authority to operate the equipment 2 Shielded interface cables and AC power cord if any must be used in order to comply with the emission limits CISPR A COMPLIANCE This device complies with CISPR...
Страница 4: ...6 1 Optional 10G SFP Transceivers 15 2 7 Making SFP DAC AOC Connection 15 2 8 Making Management Connection 17 2 9 RESET Button 17 2 10 LED Indication 17 2 11 Configuring IP Address and Password for the Device 19 2 12 Converter Function 20 2 13 Application 21 2 14 SNMP Support 21 3 Web Management 23 3 1 Start Browser Software and Making Connection 23 3 2 Login to the Device Unit 23 3 3 Main Managem...
Страница 5: ... 5 3 9 Reboot System 31 3 10 Restore Default 31 3 11 Update Firmware 31 3 12 Configuration File Transfer 32 3 13 Logout 32 Appendix A Factory Default Settings 33 ...
Страница 6: ...one SFP slot that can be installed with variety of optional transceivers supporting multiple data rates 10G 5G 2 5G 1G over multimode or single mode fiber for short reach up to long reach distance 1 1 Features The device supports the following multi rate and media conversion 10GBASE T to 10GBASE R conversion 5GBASE T to 5GBASE R conversion 2 5GBASE T to 2500BASE X conversion 1000BASE T copper to 1...
Страница 7: ...ring In band embedded firmware upgrade function Web based browsing interface SNMP and trap managed 1 2 Product Panels The following figure illustrates the front panel and rear panel of the device 1 3 Specifications RJ 45 Copper Port Compliance IEEE 802 3an 10GBASE T IEEE802 3bz 2 5 5GBASE T IEEE 802 3u 1000BASE T Connector Shielded RJ 45 jack Pin assignments Auto MDI MDI X detection Configuration ...
Страница 8: ... Cable AOC Configuration Auto negotiated line rate or forced line rate Full duplex Transmission rate 10Gbps 5Gbps 2 5Gbps 1000Mbps Network cables MMF 50 125 m 60 125 m SMF 9 125 m Eye safety IEC 825 compliant RESET Switch Functions Reset device Restore factory default LED Indicators POWER Power status MNGT Management status 10G 5G 2 5G Line rate indication LINK RJ 45 copper port link status ACT RJ...
Страница 9: ...Relative Humidity 10 90 Electrical Approvals FCC Part 15 rule Class A CE EMC CISPR32 Class A VCCI Class A Safety LVD IEC 62368 1 EN 62368 1 Software Management Functions Interfaces Web browser SNMP SNMP traps Management objects System configuration IP settings Name Password Port configuration control and status Statistics Fiber port DDM Ping Reboot Restore factory default Update firmware ...
Страница 10: ...llowing conditions occur unplug the product from the electrical outlet and replace the part or contact your trained service provider The power cable extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not operate correctly when you follow the operating instructions Do not push any ob...
Страница 11: ...tion around the device Do not place heavy objects on the device Wall mounting The device has one mounting wall on the bottom side to support wall mounting The holes support two different mounting directions Din Rail mounting For a Din Rail chassis the device can support mounting on a Din Rail An optional Din Rail mounting kit can be purchased separately as shown below ...
Страница 12: ...r area The power adapter which is used to supply the DC power for the device should have the AC voltage matching the commercial power voltage in your area Specifications Rated input voltage 100 240 VAC Rated input frequency 50 60Hz Rated output voltage 12VDC 5 Line regulation 2 Rated power 12W Output current 1A max Steps to apply the power to the device are 1 Connect power adapter DC plug to the D...
Страница 13: ...rt is featured with auto negotiation function and full capability to support connection to any Ethernet devices The port performs a negotiation process for the speed and duplex configuration with the connected device automatically when each time a link is being established If the connected device is also auto negotiation capable both devices will come out the best configuration after negotiation p...
Страница 14: ...s Multimode MMF 50 125 m 62 5 125 m Single mode SMF 9 125 m Fiber Port Configuration According to the speed negotiated by the copper port with the connected partner the SFP fiber port uses the same speed as the operating line rate for packet forwarding between copper port and fiber port automatically Line Rate RJ 45 Copper Port Interface SFP Fiber Port Interface 10Gbps 10GBASE T std 10GBASE R std ...
Страница 15: ...re assembled from shielded copper cables with a fixed length and are fitted with transceivers on either end of the cable with gauges attached These can be from 24 up to 30 AWG while 15 meters of interconnection is possible via the copper cable There are passive and active types of DAC cables Active copper wires use electronics to connect via the connections and transmissions are made via the coppe...
Страница 16: ...rconnection loss EMI immunity and flexibility etc Primarily active optical cable AOC assemblies were invented to replace copper technology in data centers and high performance computing HPC applications As we know copper passive twinax cable is heavy and bulky making it difficult to physically manage the datacenter And due to the nature of electrical signals electromagnetic interference EMI limits...
Страница 17: ... Press the button and release during operation All LEDs ON then reboot the device The boot up takes about 20 seconds and ends with all LEDs OFF Restore factory default Press the button until all LED blinks then release Restore all factory default settings Then reboot the device 2 10 LED Indication LED Function State Interpretation POWER Power status ON The power is supplied to the device OFF The p...
Страница 18: ...us ON The port link up OFF The port link down Blink The port link up and data traffic activity 10G 5G 2 5G Conversion line rate indication 5G ON 2 5G ON 10Gbps line rate 5G ON 2 5G OFF 5Gbps line rate 5G OFF 2 5G ON 2 5Gbps line rate 5G OFF 2 5G OFF 1000Mbps line rate ...
Страница 19: ...Address is an identification of the device unit in a TCP IP network Each unit should be designated a new and unique IP address in the network Refer to Web management interface for System Configuration The password is used for authentication in accessing to the device via web based interface For security reason it is recommended to change the default settings for the device unit before deploying it...
Страница 20: ...ner on the RJ 45 copper port Otherwise a fixed line rate among 5Gbps 2 5Gbps and 1000Mbps is applied for the device 2 The packet forwarding data conversion between the fiber segment and UTP segment is transparent There is no packet modification in forwarding 3 No packet type is limited in packet forwarding The types include untagged packets tagged packets BPDU packets and the reserved MAC control ...
Страница 21: ...18 Management Information Base MIB for the Simple Network Management Protocol SNMP RFC 1907 Management Information Base for Version 2 of the Simple Network Management Protocol SNMPv2 RFC 1213 Management Information Base for Network Management of TCP IP based internets MIB II RFC 1158 Management Information Base for network management of TCP IP based internets MIB II RFC 1493 Definitions of Managed...
Страница 22: ...SNMP trap messages sent by the device SNMP trap function allows the device to send trap message to an SNMP trap host over SNMP protocol when the associated trap event occurs SNMP Trap events The following events are defined for generating a trap message when the event occurs on the unit The device boot up RJ 45 copper port link down RJ 45 copper port link up link recovery SFP fiber port link down ...
Страница 23: ... web browser software make sure a unique IP address is configured for the unit 3 1 Start Browser Software and Making Connection Start your browser software and enter the IP address of the unit to which you want to connect The IP address is used as URL for the browser software to search the device URL http xxx xxx xxx xxx Factory default IP address 192 168 0 2 Factory default password 123 3 2 Login...
Страница 24: ...o no access for time out of 3 minutes System Configuration is displayed after a successful login 3 3 Main Management Menu The following information describes the basic functions of the main menu Configuration System Device information system and IP related settings Ports Port link status operation mode configuration and other per port settings Monitoring Statistics Overview List statistics for the...
Страница 25: ...Default Command to restore the device unit with factory default settings Update Firmware Command to update the device firmware Configuration File Command to transfer upload download configuration file Transfer Logout Command to logout from current web management 3 4 System ...
Страница 26: ...Address IP address used when DHCP mode is not enabled Fallback Subnet Mask Subnet mask for IP address used when DHCP mode is not enabled Fallback Gateway Default gateway IP address used when DHCP mode is not enabled Name Set the system name for this switch unit Note It is suggested to give each device unit a system name as an alternative unique identification beside IP address Password Set new pas...
Страница 27: ...k down Mode Select MNGT port operating mode Mode Auto negotiation Speed capability Duplex capability Auto Enable 10 100 1000M Full Half Forced 10 Half Disable 10M Half Forced 10 Full Disable 10M Full Forced 100 Half Disable 100M Half Forced 100 Full Disable 100M Full Auto 1000 Full Enable 1000M Full Select UTP to SFP operating mode Line rate Mode Line Rate Auto Use the speed established on the RJ ...
Страница 28: ... Any changes made locally will be undone 3 6 Statistics Overview Configuration Description Port MNGT Management port UTP RJ 45 copper port SFP Fiber port Tx Frames Total of packet frames transmitted on the port Rx Frames Total of packet frames received on the port Tx Errors Total of error packet frames transmitted on the port Rx Errors Total of error packet frames received on the port Clear Click ...
Страница 29: ...NET compliance information of the transceiver Ethernet Compliance Ethernet compliance information of the transceiver Vendor Name The vendor name of the transceiver Vendor OUI The vendor OUI of the transceiver Temperature The current temperature sensed currently inside the transceiver Voltage The working voltage sensed currently inside the transceiver TX Power The transmission optical power sensed ...
Страница 30: ...conds Apply Start the ping command Results Description Target IP Address The target IP address to which the ping command issues Status The command status Received replies The number of replies received by the system Request time outs The number of requests time out Average Response Time The average response time of a ping request in mini seconds Refresh Click to refresh all statistic counters ...
Страница 31: ... settings of the device unit with factory default values Note that this menu might change the current IP address of the device and make your current http connection lost 3 11 Update Firmware This menu is used to perform in band firmware software upgrade Enter the path and file name of new firmware image file for uploading Configuration Description Filename Path and filename warp format Browser Cli...
Страница 32: ...n file to be uploaded Browse Click to browse your computer file system for the configuration file Upload Click to start upload operation from the connected PC to the switch Download Click to start download operation from the switch to the connected PC 3 13 Logout This menu is used to perform a logout from the web management If current user does not perform any management operation over 3 minutes t...
Страница 33: ...IP Subnet mask 255 255 255 0 Fallback Gateway IP 192 168 0 1 Name Null Password 123 Inactivity Timeout secs 300 SNMP enabled Not select disabled SNMP Trap destination 0 0 0 0 SNMP Read community public SNMP Write community private SNMP Trap community public Ports Configuration Enable EEE Mode Disable MNGT port Mode Auto Line Mode Auto ...