background image

-1- 

 

 

 

 

KGS-1064-BP 

 

Industrial Managed   

10-Port Gigabit Ethernet Switches 

with 2 Dual-speed SFP Slots and 8 PoE PSE Ports 

(IEEE 802.3bt PoE) 

 

Firmware Rev1.0 up 

 

User’s Manual 

 

 

 

 

 

 

 

 

DOC.210223A 

Содержание KGS-1064-BP

Страница 1: ... 1 KGS 1064 BP Industrial Managed 10 Port Gigabit Ethernet Switches with 2 Dual speed SFP Slots and 8 PoE PSE Ports IEEE 802 3bt PoE Firmware Rev1 0 up User s Manual DOC 210223A ...

Страница 2: ...rmission from KTI Networks Inc KTI Networks Inc reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc to provide notification of such revision or change For more information contact 15F 7 No 79 Sec 1 Hsin Tai Wu RD His chih New Taipei City Taiwan Fax 886 2 26983873 E mail kti ktinet com tw URL http www kt...

Страница 3: ...the interference that may cause undesired operation CE NOTICE Marking by the symbol indicates compliance of this equipment to the EMC directive of the European Community Such marking is indicative that this equipment meets or exceeds the following technical standards EN 61000 6 4 EN 61000 3 2 EN 61000 3 3 EN 61000 6 2 IEC 61000 4 2 IEC 61000 4 3 IEC 61000 4 4 IEC 61000 4 5 IEC 61000 4 6 IEC 61000 ...

Страница 4: ...ber Connection 20 2 10 Making PoE PSE Connections 22 2 11 LED Indication 24 2 12 Making Console Connection 25 3 Managing the Switch 26 3 1 IP Address Password 26 3 2 Configuring IP Address Password via console and telnet 26 3 3 Configuring IP Address via Web Interface 27 3 4 Reference Manuals for Web Console Telnet Management 29 3 5 Configuration for SNMP Management 30 3 6 SNMP MIBs 31 3 6 1 SNMP ...

Страница 5: ... 10 port industrial managed Gigabit Ethernet switch which is featured with the following communication ports Eight 10 100 1000Mbps Gigabit copper ports with PoE function Two dual speed SFP slots for 100Base FX 1000Base X One RS 232 console port ...

Страница 6: ...DHCP DHCPv6 client DHCP relay DNS client NTPv4 IPv6 support System Syslog Configuration down upload Software upload Security NAS 802 1X MAC based Web CLI authentication IP MAC binding TACACS IP source guard Layer 2 QoS 802 1Q MAC based Protocol based Private IP subnet VLAN Port Isolation Storm control for UC MC BC packets Static MAC configuration IGMP v2 v3 snooping MLD v1 v2 snooping DHCP snoopin...

Страница 7: ... 7 1 2 Product Panels The following figure illustrates the front panel and rear panel of the switch Front panel 154BTop panel ...

Страница 8: ...rol Transmission rate 10Mbps 100Mbps 1000Mbps Duplex support Full Half duplex Network cable Cat 5 UTP Dual speed SFP Slots Port 9 Port 10 Compliance IEEE 802 3u 100Base FX IEEE 802 3z 1000Base SX LX Connectors SFP for optional SFP type fiber transceivers Configuration Auto 1000Mbps Full duplex Forced 100Mbps Full duplex Transmission rate 100Mbps and 1000Mbps Network cables MMF 50 125 m 62 5 125 m ...

Страница 9: ...SE output 2 The maximum output power at the PSE end for the requested PD class 3 The minimum power received at the PD end with maximum output at the PSE end in worst case Power Delivery 95W max per port at port output for Cat 5 distance up to 100 meters PSE power pins Pin 1 2 4 5 Vpoe Pin 3 6 7 8 Vpoe Vpoe comes from DC power input Power delivery 95W max at port output Depending on DC power voltag...

Страница 10: ... x 106 x 60 mm HxDxW Housing Enclosed metal with no fan Mounting Din rail mounting Panel mounting optional 860BUEnvironmental Operating Temperature Typical 30 70 Storage Temperature 40 85 Relative Humidity 5 95 non condensing 864BUElectrical Approvals FCC Part 15 rule Class A CE EN 61000 6 4 EN 61000 6 2 EMC VCCI Class A Safety LVD IEC 62368 1 EN 50121 4 EMC for railway applications ...

Страница 11: ... extension cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not operate correctly when you follow the operating instructions Do not push any objects into the openings of your system Doing so can cause fire or electric shock by shorting out interior components Operate the product only from t...

Страница 12: ...The steps to mount the switch onto a DIN rail are 1 1287BInstall the mounting bracket onto the switch unit as shown below 2 1288BAttach bracket to the lower edge of the DIN rail and push the unit upward a little bit until the bracket can clamp on the upper edge of the DIN rail 3 1289BClamp the unit to the DIN rail and make sure it is mounted securely ...

Страница 13: ... 13 Dimensions ...

Страница 14: ...unting bracket The bracket supports mounting the switch on a plane surface securely The mounting steps are 1 1290BInstall the mounting bracket on the switch unit 2 1291BScrew the bracket on the switch unit 3 1292BScrew the switch unit on a panel Three screw locations are shown below ...

Страница 15: ... 15 Dimensions ...

Страница 16: ... Vdc Negative input terminal Vdc Input specifications Working voltage range Applications Power output at PSE port 12V 60VDC General 45V 57VDC PoE PoE 51V 36W max 53V 57VDC PoE 53V 95W max A 2P terminal plug is provided together with the switch as shown below Power wires 24 12AWG IEC 0 5 2 5mm2 1 meter max ...

Страница 17: ... 4 5 Alarm relay output NC Normal Closed contacts Shorted Normal Open Alarm NC Either pair can be used depending on the logic requirement for the relay monitoring system Use the provided 3P terminal plug for signal wiring and plug into the contacts Alarm Events 196BInput power failure 197BSpecific port link down The specific ports can be configured by software OPA alarm if optical power is higher ...

Страница 18: ... power Check whether the network is recovered The button can also be used to restore the software configuration settings to factory default values The operations are Operation Function Press the button and release during switch operation Reset boot up the switch The boot up takes about 20 seconds and ends with all LED yellow ON and green ON then all OFF once Press the button until all LED yellow O...

Страница 19: ...le for MDI to MDI X connection It simplifies the cable installation Auto negotiation Function The ports are featured with auto negotiation function and full capability to support connection to any Ethernet devices The port performs a negotiation process for the speed and duplex configuration with the connected device automatically when each time a link is being established If the connected device ...

Страница 20: ...rs 100Mbps based 100BASE FX SFP transceivers Installing SFP Fiber Transceiver 217BTo install an SFP fiber transceiver into SFP slot the steps are 1 Turn off the power to the switch 2 Insert the SFP fiber transceiver into the SFP slot Normally a bail is provided for every SFP transceiver Hold the bail and make insertion 3 Until the SFP transceiver is seated securely in the slot place the bail in lo...

Страница 21: ...Port Speed Configuration There are three options for configuring port speed via software for SFP Port 9 and Port 10 The options are Port Mode Description Auto Auto detection for the type of the installed SFP transceiver by reading DDM data 100Mbps transceiver Non auto negotiation forced 100Mbps full duplex 1000Mbps transceiver Auto negotiation 1000Mbps full duplex 100Mbps FDX Non auto negotiation ...

Страница 22: ...ssification for the Compliant PD Types and Power Level Compliant PD classes IEEE std PSE output power max PD available power min 802 3af 802 3at 802 3bt Class 1 4W 3 84W Class 2 7W 6 49W Class 3 15 4W 13W Class 4 32W 25 5W Class 5 45W 40W Class 6 60W 51W Class 7 75W 62W Class 8 90W 71 3W RJ 45 Pin Assignments of the device s PSE Port Pin PoE power 1000Base T 10 100Base TX 1 Vpoe BI_DB RX 2 Vpoe BI...

Страница 23: ...PSE output power max 2 Cable power pairs 3 PD available power min 4 Class 1 45 57V 5 3W 2 3 84W Class 2 45 57V 8 5W 2 6 49W Class 3 45 57V 19W 2 13W Class 4 45 57V 36W 4 25 5W Class 5 51 57V 51W 4 40W Class 6 51 57V 68W 4 51W Class 7 53 57V 83W 4 62W Class 8 53 57V 95W 4 71 3W 1 The minimum DC power voltage to support the specified maximum PSE output 2 The maximum output power at the PSE end for t...

Страница 24: ...error or system Green ON Initialization completed with no error Port1 Port 8 SPEED_LED Port speed status Green ON Speed is 1000Mbps Yellow ON Speed is 10Mbps or 100Mbps BLINK PoE power is on LINK_LED Port link status Green ON Port link is established No traffic Green BLINK Port link is up and there is traffic OFF Port link is down Port 9 Port 10 Speed _LED Port speed link status Green ON A 1000Mbp...

Страница 25: ...ction The connector designed for the console port is RJ 45 Pin Assignments Pin RS 232 signals IN OUT 1 2 7 8 NC 3 RxD IN 6 TxD OUT 4 5 GND Baud Rate information Baud rate 115200 Data bits 8 Parity None Stop bit 1 Flow control None ...

Страница 26: ...f the switch 192 168 0 2 255 255 255 0 The switch uses local authentication instead of RADIUS authentication with factory defaults Fixed Username admin Default password No password is required with factory default However the password is used for local authentication in accessing to the switch via console telnet and Http web based interface For security reason it is recommended to change the defau...

Страница 27: ...ete user_name Refer to Operation manual for telnet and console management 3 3 Configuring IP Address via Web Interface Start Web Browser Start your browser software and enter the default IP address of the switch unit to which you want to connect The IP address is used as URL for the browser software to search the device URL http 192 168 0 2 Login to Switch Unit When browser software connects to th...

Страница 28: ... 28 No password is required Click OK to login into the switch Web Page after a Successful Login Select Configuration System IP to configure IP address Configuration Description ...

Страница 29: ...will relay DNS requests to the current configured DNS server on DUT and reply as a DNS resolver to the client device on the network Save Click to save the changes Reset Click to undo any changes made locally and revert to previously saved values Renew Click to renew DHCP This button is only available if DHCP is enabled 3 4 Reference Manuals for Web Console Telnet Management The following operation...

Страница 30: ...IPv6 Destination ipv6_addr SNMP Trap Authentication Failure enable disable SNMP Trap Link up enable disable SNMP Trap Inform Mode enable disable SNMP Trap Inform Timeout timeout SNMP Trap Inform Retry Times retries SNMP Trap Probe Security Engine ID enable disable SNMP Trap Security Engine ID engineid SNMP Trap Security Name security_name SNMP Engine ID engineid SNMP Community Add community ip_add...

Страница 31: ...nities that permit to access to SNMPv3 agent USM User based Security Model user table for SNMPv3 VACM View based Access Control Model Viewer table for SNMPv3 Group table for SNMPv3 Accesses group table for SNMPv3 3 6 SNMP MIBs The switch provides the following SNMP MIBs RFC 1213 MIB II RFC 2674 QBridge MIB VLAN MIB RFC 2819 RMON Group 1 2 3 9 RFC 2863 Interface Group IF MIB RFC 3411 SNMP Managemen...

Страница 32: ...P Firmware update over SNMP Private OPA function MIB OPA configuration for the SFP ports Private ALS function MIB ALS configuration for the SFP ports One product MIB file is also available in the product CD for SNMP manager software 3 6 1 SNMP Traps In addition to the SNMP standard traps the device is equipped with private OPA alarm traps The traps are Alarm trap Port TX power lower than the minim...

Страница 33: ...ion can support more than one ring connection within a switch It is also able to work with RSTP support concurrently in the switch Some basic information is Supports up to five rings in one switch Supports up to 30 member switches in one ring Provides fast response time than RSTP protocol Works with RSTP protocol concurrently within one switch The following figure illustrates a configuration that ...

Страница 34: ...the same time 4 2 Redundant Ring Applications with industrial standard RSTP protocol It also can be done to support a ring connection using industrial standard RSTP function and establish a backup path In case that any link failure occurs the backup path can link up immediately to recover the network operation ...

Отзывы: