2. Connect Air Hose 

Move Selector Switch to VACUUM and connect an Air Hose. 

   

Note: Level of Air Pressure must be 0.6 to 1.0MPa   

(6.0 to 10.0kgf/cm2) . 

Negative pressure must be less than -0.09MPa when 

covering Corn Plug with finger. 

 

3. Vacuum Drawing 

(1)  Insert a Corn Plug into the Radiator Filler Port. 

(2)  Wait  until  pointer  of  Vacuum-Gauge  reaches  to  the  Green 

Zone (around -0.09MPa) and come to a standstill. 

(3)  Wait  until  pointer  of  Vacuum-Gauge  reaches  to  the  Green 

Zone (around -0.09MPa) and come to a standstill. 

 

Note: In case temperature of residue coolant liquid in auto is 

high,  or  coolant  liquid  is  left  on  water  hose,  radiator 

doesn’t come under negative pressure. 

 

4. Injecting Coolant 

(1)  AE401  automatically  starts  injecting  Coolant  after  Selector 

Switch is moved to CHARGE. 

(2)  Coolant  Injecting  work  is  finished  when  Vacuum-Gauge 

reaches to ZERO and stop.   

 

Note: Keep pressing Corn Plug down until Coolant Injecting 

work is finished. 

Do not leave condition of Vacuum Drawing. 

Do not inject coolant until pointer reaches to green zone. 

 

5. Gather residual Coolant liquid inside Hose 

(1)  Remove the Corn Plug from Filler Port and left up a Hose. 

(2)  After  gathering  all  residual  liquid,  remove  Air  Hose  from  Air 

Coupler. 

 

Note: All residual coolant liquid is able to gather by free fall. 

Vacuum drawing process is not necessary for gathering 

coolant liquid. 

 

 

 

6. Check an amount of Coolant on the reserve tank then Complete Work 