background image

6

7

      FEATURES

2      CAUTIONS

1

3.Package

1

ARMORED DOME CAMERA

2

SURFACE MOUNT

3

VIDEO OUTPUT TEST CABLE

4

OPERATION MANUAL

5

SCREW(M4x10) - 4ea

SCREW(5x30)   - 4ea

SCREW(M4x40.SUS)   - 4ea 

L WRENCH - T20

6

MOUNT GUIDE

Содержание KPC-VDN101

Страница 1: ...Thank you for choosing our high quality camera Before attempting to connect or operate please read and follow these instructions OPERATION MANUAL HIGH RESOLUTION ARMORED DOME CAMERA M063 VDN101 002...

Страница 2: ...nstallation 6 Connection 7 Dimensions 8 Specifications 9 Setup menu operation SETUP MENU SETUP MODE CAMERA ID LENS SHUTTER WHITE BALANCE LANGUAGE MODE SETUP RESET 10 Function Menu operation FUNCTION M...

Страница 3: ...quipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio tv technician for help Any changes or modifications in constructi...

Страница 4: ...man health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources This product should not be...

Страница 5: ...DC12V AC24V Motion Detection 3 Axis Gimbal The Service Video Connector also provides the installer with an easy way of configuring the camera Service Video connector Pan Rotation Horizontal Rotation...

Страница 6: ...FEATURES 2 CAUTIONS 1 3 Package 1 ARMORED DOME CAMERA 2 SURFACE MOUNT 3 VIDEO OUTPUT TEST CABLE 4 OPERATION MANUAL 5 SCREW M4x10 4ea SCREW 5x30 4ea SCREW M4x40 SUS 4ea L WRENCH T20 6 MOUNT GUIDE...

Страница 7: ...4 Overview and function CONTROL FUNCTION OSD JOYSTICK LEFT UP RIGHT DOWN MENU Name LED Type Name Standard...

Страница 8: ...5 Installation Standard Type LED Type Mount Guide...

Страница 9: ...CREWS Installation of the camera with JUNCTION BOX Installation of the camera on the wall Installation of the camera on the 3 4 NPT PIPE Installation of the camera on the JUNCTION BOX Check the safe w...

Страница 10: ...6 Connection 11 When you install the camera please glue up the end of cable to keep it stable in order to protect the camera from the humidity problems DUAL DC 12V AC24V DC 12V...

Страница 11: ...Standard Type LED Type 12 When you fix the focus around 22 0mm in f9 0 22 0mm Varifocal lens please set short distance focus approximately 3M and do not set long distance focus Surface Mount Type Flus...

Страница 12: ...Vp p Composite 75 unbalanced Power Consumption DC12V DC 12V 10 Max 110mA Dual DC 12V 10 160mA AC 24V 10 170mA 1 8W Operating Temperature 10 50 Storage Temperature 20 60 Operating Humidity 10 80 Optio...

Страница 13: ...14 SETUP MENU CAMERA ID ON OFF LENS MANUAL VIDEO DC SHUTTER AUTO FLK FIXED MANUAL WHITE BAL ATW AWB FIXED MANUAL FUNCTION BLC AGC DAY NIGHT PRIVACY MIRROR GAMMA MOTION ADJUST CONTRAST SHARPNESS CB_GA...

Страница 14: ...MENU button in CAMREA ID ID SETUP menu is displayed on the monitor 2 1 CAMERA ID setup Character is changed each time UP DOWN button is pressed You can select up to 63 letters Character position is ch...

Страница 15: ...lue Press MENU button to return to the previous screen 4 SHUTTER 4 1 SHUTTER setup Press LEFT or RIGHT button in SHUTTER to select the mode to AUTO FLK FIXED MANUAL 4 2 SHUTTER AUTO setup AE LEVEL set...

Страница 16: ...1 50 or 1 60 255 MAX 1 100 000 5 WHITE BALANCE 5 1 WHITE BALANCE setup Press LEFT or RIGHT button in WHITE BAL to select the mode to ATW AWB FIXED MANUAL 5 2 AWB FIXED setup Press MENU button in FIXE...

Страница 17: ...HARPNESS setup Adjust aperture value 0 31 6 4 CB_GNIN setup Adjust COLOR CB_GAIN value 0 255 6 5 CR_GAIN setup Adjust COLOR CR_GAIN value 0 255 7 LANGUAGE Mode Setup DEFAULT value ENGLISH After select...

Страница 18: ...et details using LEFT RIGHT button Press MENU button in RETURN to go to SETUP menu 2 BLC 2 1 BLC SETUP mode Press MENU button in BLC ON 2 2 BLC AREA setup Use UP DOWN LEFT RIGHT button to move the ARE...

Страница 19: ...to BLC SETUP mode 2 4 BLC RATIO setup Use UP DOWN button to move to BLC RATIO Use LEFT RIGHT button to change BLC LEVEL value 0 63 0 MIN 63 MAX Press MENU button in RETURN to move to FUNCTION MODE 3 A...

Страница 20: ...Night function is under the control of photocell DELAY DAY NIGHT or NIGHT DAY conversion time setup 0 No DAY NIGHT AUTO conversion 1 63 Can set from 1 second to 15 seconds START LEVEL DAY NIGHT conve...

Страница 21: ...ayed on the bottom picture Press MENU button Details of each area is displayed 5 2 PRIVACY details setup Select AREA SEL PRIVACY 0 3 AREA STATE 0 3 AREA ON OFF LEFT Change left portion of each AREA si...

Страница 22: ...tting OFF ON setting Use LEFT RIGHT button Left and Right side is switched as shown on the picture 7 GAMMA 7 1 GAMMA setup DEFAULT 0 45 In FUNCTION MODE use UP DOWN button to select GAMMA Use LEFT RIG...

Страница 23: ...move AREA setting position Use MENU button to set and release AREA Press MENU button for more than 1 second to move to MOTION AREA mode 8 2 2 MOTION AREA mode ALL CLEAR Clear all set AREA ALL SET Set...

Страница 24: ...iate device set the 75 Hi z properly and check the terminals Please check if an auto iris lens is being used and adjust the brightness level There is a problem with the camera operation Please check i...

Отзывы: