3. Product Description
Description and Function
1. Infrared LED – These LEDs emit infrared radiation.
2. Sensor – Light sensor.
3. Service Video Connector – Outputs video to the monitor.
4. Factory reset – Factory reset button.
5. Status LED – LED to indicate camera status.
6. Network Connector – The Network Camera connects to the network via a standard
network cable, and automatically detects the speed of the local network segment
(10BaseT/100BaseTX Ethernet). PoE Supported.
7. Digital Input – Connects signal from external sensor.
8. Digital Output – Connects signal to external alarm. (Max. current - DC 12V, 70mA)
9. Power Input(DC12V) – Connect DC 12V power..
4. Dimensions
M124-Ni700/720HD-001
Megapixel Network Camera
KNC-Ni700HD / KNC-Ni720HD
Installation Guide
Table of Contents
1.INTRODUCTION
2.PACKAGE CONTENTS
3.PRODUCT DESCRIPTION
4.DIMENSIONS
5.INSTALLATION
6.IP ADDRESS ASSIGNMENT
7.TERMINAL BLOCK CONNECTORS
1. Introduction
KNC-Ni700HD, KNC-Ni720HD Installation Guide
This installation guide provides instructions for installing the Network Camera on your
network. For all other aspects of using the product, please see the User’s Manual,
available on the CD included in this package, or from http://www.ktnc.co.kr
Installation steps
1. Check the package contents against the list below.
2. Read the product description.
3. Install the hardware.
4. Set an IP address.
5. Set the admin and user ID and password. (See User’s Manual)
I m p o r t a n t !
This product must be used in compliance with local laws and regulations.
2. Package Contents
KNC-Ni700HD / KNC-Ni720HD
Screw-4ea
Software CD
L Wrench and RJ45
coupler
Service Video Output Test Cable
Installation Guide
5. Installation
• Camera Mounting Position
• External Zoom & Focus Adjustment
• Connection
1. Connect the camera to the network using a UTP cable (CAT.5).
Power can be supplied via the network cable (PoE)
2. Connect DC 12V to the power terminal. This is not necessary if the Network Camera is
connected to a PoE hub or midspan.
3. Check that the indicator LEDs indicate the correct conditions.
4. Connect the analog monitor to the service video connector for adjusting focus, then press and quickly
release the reset switch for focus assistant mode.
Then you can select normal view or focus view mode using the reset switch.
Caution: When you use focus assistant mode, “Focus View” mode is recommended for more exact focus.
Caution: Focus assistant mode will be automatically exited after 3 minutes for normal operation.
Digital Input
Digital Output
< Cable Concealed Thru Bracket >
90
˚
TLIT
360
˚
PAN
360
˚
PAN
90
˚
TLIT
Opening the window cap to adjust the zoom and focus can cause humidity
problems in the camera. The External Zoom and Focus system with our
state-of-the-art technology provides easy camera installation without
opening the window cap to adjust zoom and focus the lens.
❶
❷
❸
❹
❺
❻
❼
❽
❾