background image

Solar and differential temperature controller

SOL3-7

Quick installation and
operating manual

Firmware version 1.07, 
April 2011 

Содержание SOL3-7

Страница 1: ...Solar and differential temperature controller SOL3 7 Quick installation and operating manual Firmware version 1 07 April 2011 ...

Страница 2: ...the controller The device may only be installed started up or operated by trained and experienced personnel familiar with the product The controller has been designed for use in electrical power systems For wiring and maintenance you are required to observe the relevant safety regulations Content Installation 3 Mounting 3 Electrical connection 3 Systems 5 Operation and display 8 Operating controls...

Страница 3: ...ions are available at http www KT Elektronik de Document Content Mounting and operating instructions detailed decription of the device characteristics System schemes Schemes of all supported hydraulic systems Installation Mounting Panel mounting Top hat rail mounting Wall mounting Electrical connection The wiring diagram is shown on the back side of the housing This diagram is usable for most of t...

Страница 4: ...UP M M I o 2 0 0 CP1 CTP SUV I o 2 0 I CP1 CTP SUV UP M M System T 21 T 23 T 24 T 26 T 27 T 29 T 30 I o 2 I 0 CP1 CTP SUV NH I o 2 I I CP1 NH CTP SUV UP M M I o 2 2 0 CP1 CTP SUV ZP I o 2 2 I CP1 ZP CTP SUV UP M M I o 2 30 CP1 CTP SUV ZP NH I o 3 0 0 CP1 SP1 SP2 I o 3 0 I CP1 SP1 SP2 UP M M I o 3 I 0 CP1 SP1 SP2 NH I o 3 I I CP1 NH SP1 SP2 UP M M I o 3 2 0 CP1 SP1 SP2 ZP I o 3 2 I CP1 ZP SP1 SP2 U...

Страница 5: ...I CP1 CP2 ZP SUV UP M M 3 2 3 0 CP1 CP2 SUV ZP NH 3 o I 0 0 CP1 CP2 CTP 3 o I 0 I CP1 CP2 CTP UP M M 3 o I I 0 CP1 CP2 CTP NH 3 o I I I CP1 CP2 CTP NH UP M M 3 o I 2 0 CP1 CP2 CTP ZP 3 o I 2 I CP1 CP2 CTP ZP UP M M 3 o I 3 0 CP1 CP2 CTP ZP NH 3 o 2 0 0 CP1 CP2 CTP SUV 3 o 2 0 I CP1 CP2 CTP SUV UP M M 3 o 2 I 0 CP1 CP2 CTP SUV NH 3 o 2 2 0 CP1 CP2 CTP SUV ZP 3 o 2 3 0 CP1 CP2 CTP SUV ZP NH 3 o 3 0 ...

Страница 6: ...F1 KW WW CTP Kollektor feld 2 CP2 CF2 CP1 System I 2 0 0 1 collector array 2 storage tanks valve System 2 2 0 0 2 collector arrays valve 2 storage tanks valve System 3 2 0 0 2 collector arrays 2 pumps 2 storage tanks valve Speicher1 BE BA AE AA Kollektor feld1 CF1 CF1 SF1 CP1 KW WW SF2 Speicher2 SUV Speicher1 BE BA AE AA Kollektor feld 1 CF1 CF1 SF1 CP1 KW WW Kollektor feld 2 CF2 CUV SF2 Speicher2...

Страница 7: ...ions The extentions e g heating circuit auxilary heating and circutation can be combined They are coded in the lower digits of the system schema indicator Xxx 0 0 no extention xxx I 0 auxilary heating xxx 0 I heating ciruit xxx 2 0 circulation pump xxx I I auxilary heating and heating ciruit xxx 3 0 auxilary heating and circulation pump xxx 2 I circulation pump and heating ciruit xxx 3 I auxilary ...

Страница 8: ... Control operation active display of informations about the operation of the controller normal position information level Control operation deactivated frost protection is activated controller is still active Manual mode Valves and pumps can be controlled manually Rotary switch Parameter Solar threshold on Solar threshold off Times of use and operating modes for heating circuit 1 auxilary heating ...

Страница 9: ...c mode Normal mode Automatic mode Night mode Manual mode Night mode Day mode Stand by mode Day mode Manual mode Collector pump CP1 Manual mode Stand by mode Collector exchanger pump CTP Stand by mode Pump UP1 Storage tank pump SP1 Circulation pump ZP Valve M1 OPEN Collector valve CUV Collector pump CP2 Auxilary heating NH Valve M1 CLOSE Storage tank valve SUV Storage tank pump SP2 Temperature diff...

Страница 10: ...re AF Temperature at storage tank sensor SF1 Room temperature RF Temperature at storage tank sensor SF2 Temperature at flow sensor of heating circuit VF Temperature at collector sensor CF1 Temperature at flow sensor CVF collector to storage tank 2 Temperature at collector sensor CF2 Temperature at return flow sensor CRF storage tank to collector Operating hours of solar circiut Setting the control...

Страница 11: ... time of first time of use Turn rotary pushbutton to modify stop time of first time of use Push rotary push button Confirm Stop time Display next time of use or next day of week to check Turn rotarypush button Display End Push rotary pushbutton leave time of use level of heating circiut Display Heating circiut circuit 1 Check and set party mode Using the Party mode function the controller continue...

Страница 12: ...numbers When a configuration level is opened the activated function blocks are indicated by a black square on the right hand side below the function block number For more details on function blocks refer to the operating manual The functions are grouped by topics CO1 Heating circiut 1 CO5 System wide functions CO3 Solar circuit CO6 Modbus communication CO4 Auxilary heating DHW circuit Set rotary s...

Страница 13: ...tary pushbutton Modify further parameters or confirm End to leave parameter level Resetting to default values All parameters and function blocks set over the rotary switch as well as parameters in PA parameter levels and function blocks in CO configuration levels can be reset to their default settings efactory default Set rotary switch to configuration and parameter level Symbol parameter blink Di...

Страница 14: ... heating NH SU Activation deactivation of storage tank valve SUV CTP Activation deactivation of collektor external heat exchanger pump CTP TdS Activation deactivation of temperature difference switch TdS Set rotary switch to manual mode Display P0S I Push rotary push button Display Positioning value of valve M1 Turn rotary push button Edit positioning value of valve M1 Push rotary pushbutton Confi...

Страница 15: ...0 0 2 0 TN resettime 1 to 999s 120s TV derivative actiontime 0to999s 0s TY valvetransittime 5 10 15 240s 45s CO1 F12 0 On Off Controll Functionblockparameters Hysteresis 1 to 30 C 5 C min ONtime 0 to 10min 2min min OFFtime 0 to 10min 2min 13 Limitationofdeviationfor OPENsignal 0 CO1 F13 1onlywithCO1 F12 1 Functionblockparameters max deviation 2 to 10 C 2 C FFunctionblocknumber FDFactorydefault CO3...

Страница 16: ...mmermode 01 01to31 12 30 09 No ofdaysuntildeactivation 1to3 1 Outdoortemperaturelimitforsummermode 0 to 30 C 18 C 05 Delayedoutdoortempera tureadaptationwhen temperaturedecreases 0 06 Delayedoutdoortempera tureadaptationwhen temperatureincreases 0 CO5 F05 06 1 Functionblockparameters Delayperhour 1 to 6 C h 3 C h 08 Automaticsummer winter time 1 09 FrostprotectionprogramII 1 CO5 F09 0 Frostprotect...

Страница 17: ...mbers 2 3 4 Point 1 Flow temperature 5 to 130 C 1 70 C 2 55 C 3 40 C 4 25 C Flow temperatures of the points 2 3 4 are marked by squares below the numbers 2 3 4 Point 1 Reduced flow temperature 5 to 130 C 1 60 C 2 40 C 3 20 C 4 20 C Reduced flow temperatures of the points 2 3 4 are marked by squares below the numbers 2 3 4 Point 1 Return flow temp 5 to 90 C 1 to 4 65 C Return flow temperatures of t...

Страница 18: ... 120 s Follwow up time collector ext heat exchanger pump 0 to 250 s 10 s PA4 Auxilary heating Storage tank temperature Parameter designation Range of value FD Comment Day set point for storage tank temperature 5 to 90 C 45 C Night set point for storage tank temperature 5 to 90 C 10 C Hysteresis for storage tank temperature 0 to 30 K 5 K Temperature difference to delay auxilary heating 0 to 20 K 0 ...

Страница 19: ...ording to VDE 0110 Humidity rating F according to VDE 40040 Noise immunity According to EN 61000 6 1 Noise emission According to EN 61000 6 3 Installation Panel mount wall mount top hat rail mount Dimensions LxWxH mm 144 x 98 x 60 Weight Approx 0 5 kg Material Mat Nr Identification Despription 37387 SOL3 7 SOL3 7 Solar thermal and differential temperature controller 11988 KOM232PC Adapter to conne...

Страница 20: ...KT Elektronik GmbH Berlinickestrasse 11 12165 Berlin Telefon 030 79 08 05 0 Telefax 030 79 08 05 20 e mail info kt elektronik de Internet http www kt elektronik de KA_37387_SOL3 7_EN004 05 2011 ...

Отзывы: