code R30015.110en www.kseniasecurity.com
ed. 01/2021
POWER SUPPLY STATION TECHNICAL DATA
•
Power supply voltage: 230 V~ -15/+10% 50 Hz 0.8 A
•
Power Supply Battery Charger* (Type A norm EN50131-6): 14.2V ± 1% 50W
•
Current consumption (medium): 50mA
•
Current consumption (max): 100mA
•
Maximum current available for external devices: 1450 mA grade 2 - 0.55 mA grade 3
•
Max. output voltage ripple: 13.8 V- da 10 a 15 V- 120 mV
•
Max. current for battery charging: 750 mA
•
Maximum battery recharge time to 80%: 12 V – 18 Ah 24 h
•
Deep discharge voltage protection: 10 V
•
Low battery threshold (restore): 11 V- (12.5 V-)
•
Low voltage threshold: 11 V-
•
Over voltage protection voltage: 17.5 V
•
Backup battery: 18Ah
•
Overall dimensions (WxHxD): 325x400x90 mm
•
Weight (with battery): 4.2 Kg (10 Kg)
•
Temperature operating range: +5 / +40 °C - Humidity (not condensed): 95 %
* Note: The power supply is calibrated at 15V, compatible with control panels of lares 4.0 family. When
using with lares control panels or with opis, act on the trimmer of charger to adjust the voltage at 14.2V.
LEDs SIGNALATION (M - B - S)
M
Power Supply status
Steady: Correctly working
Off: Power supply fault or missing AC network
B
Battery Voltage status
Steady: Correctly working
Off: Fault or low battery level
S
System Status
Steady: Correctly working
Flashing: Tamper and/or BUS IN connection fault
detail of PCBA: LEDs