OUTPUTS WORKING MODES
STAND-ALONE
It is possible to manage relay outputs through the closure of the inputs
present on
auxi wls
or using the
opera
remote commands previously
programmed.
Both in stand-alone or directly connected to the Panel, the relay outputs can be programmed as follows:
•
INDIPENDENT OUTPUTS
: both the outputs are completely indipendent and can be separately programmed (
eg. the first output as bistable and
the second one as monostable
)
•
STPD (change over switch) OUTPUTS
: the outputs are considered as an unique
logic output. The first is Normally Open and the second one is Normally Closed.
The outputs are dependent and cannot be separately managed. The
commutation of the first relay implies the commutation of the second one.
•
INTERLOCKED OUTPUTS
: in this mode, particularly useful to manage electric
motors, the relay outputs cannot be active at the same time. In case an output
is active and the other one has to be activated, both of the outputs will de
activated for half a second and then will commutate.
The outputs can be programmed as Bistable or Monostable, regardless the selected configuration.
INDIPENDENT
INTERLOCKED
CHANGE
OVER SWITCH
(SPTD)
LARES CONTROL PANELS
Depending on its size,
lares
control panels can manage up to 64
auxi
wls
. The activation of the outputs can be managed through scenarios or
using the built-in inputs on
auxi wls
. Inputs present on
auxi wls
can work
in different ways:
•
Local
: no panel zone has to be associated to the input, in order to work
in this mode. The 2 inputs present on device could be used to change
the status of the outputs.
• As Panel zone
: in order to work in this mode, a Panel zone has to be
assigned to the input. The closure / opening of inputs is notified to the
Panel that will performs the programmed actions during the real time of
the associated zone or its restoral.