background image

FIREBREAK SA

14 COMBRINCK STREET, ALRODE, ALBERTON. 1451

Tel No: 

+27 11 908 6960 

| E

m

ail: 

enquiries@

f

irebreaksa.co.za

 

Web

s

ite : 

www.

f

irebreaksa.co.za

KS-8810

 

Hand Lamp

The ex-proof hand lamp KS-8810 is a hand lamp for use in potentially explosive areas and is used, for 

example, as a fire brigade torch. The light torch is operated by four AA cells and, despite its low weight, is 

shock and impact protected.

 

Features:

Built-in pressure relief valve

, m

agnetic switch with safety lock

Impact and shock-resistant housing

.

Color: Yellow 

4 x AA Batteries 

not supplied

REFLECTOR

140 GRAMS

IP67

POWER

-LIGHT

WORK

-LIGHT

FLASH

-LIGHT

180/70/180 

LUMENS

120/80/120 

METERS

8/30/80 

HOURS

II 

1G

 Ex ia IIC 

T4

-20°C

 <Ta< 

+40°C

TEMP

-20° / +40°

ZONE

0

Содержание SKS-8800

Страница 1: ...sed for example as a fire brigade torch The light torch is operated by four AA cells and despite its low weight is shock and impact protected Features Built in pressure relief valve magnetic switch with safety lock Impact and shock resistant housing Color Yellow 4 x AA Batteries not supplied REFLECTOR 140 GRAMS IP67 POWER LIGHT WORK LIGHT FLASH LIGHT 180 70 180 LUMENS 120 80 120 METERS 8 30 80 HOU...

Страница 2: ...ng II 1G Ex ia IIC T4 Ga all I M1 Ex ia I Ma KS 8890 only Issuer of EC type approval UL International Demko A S Borupvang 5A 2750 Ballerup Denmark Sira Certification Service Unit 6 Hawarden Industrial Park Hawarden CH5 3US United Kingdom Applied standards concerning the ATEX directive EN 60079 0 2009 EN 60079 0 2012 A11 2013 EN 60079 11 2007 EN 60079 11 2012 EN 60079 26 2007 EN 60079 26 2015 Appli...

Страница 3: ...able casing Stoßsichere Linse High Impact LENS Rutschfester Griff Non Slip Handle Gut sichtbarer gelber Leuchtenkörper High Visibility yellow colour body Sicherheitsverschluss Safety Lock Standards Standards 1 UL 913 7th Edition 2011 09 23 2 CSA C22 2 No 157 92 Reaffirmed 2013 3 EN 60079 0 2009 Edition 4 EN 60079 11 2007 Edition 5 EN 60079 26 2007 Edition 6 IEC 60079 0 5th Edition 7 IEC 60079 11 5...

Страница 4: ...ufwand wieder ein Schrauben Sie an schließend den Frontdeckel bis zum Anschlag des Gewindes auf das Gehäuse Warning The screw should be secured tightly after replacing the batteries Install the batteries in the correct assembly When re insert reflector set with smart design please gently insert it it could slowly slide into groove and fit it well please do not over force on it Closing the flashlig...

Отзывы: