6 Commissioning/Start-up/Shutdown
33 of 72
Vitachrom
Typical quench liquids:
▪
Water with a conductivity of 100-800 µS/cm
▪
Water/glycol mixtures
▪
Glycerine
6)
Temperature and pressure
limits
Table 11:
Permissible temperature and pressure limits
Minimum
Maximum
Temperature
-10 °C
and
T
Melting
+10 °C
7)
60 °C
and
T
Boiling
-10 °C
7)
Pressure
Ambient pressure
0.5 bar gauge pressure
One-way quench
The one-way quench supply should be adjusted to a constant flow ≥ 0.3 l/min.
6.2 Operating limits
DANGER
Non-compliance with operating limits for pressure, temperature, fluid handled and
speed
Explosion hazard!
Hot or toxic fluid could escape!
▷
Comply with the operating data indicated in the data sheet.
▷
Never use the pump for handling fluids it is not designed for.
▷
Avoid prolonged operation against a closed shut-off element.
▷
Never operate the pump at temperatures, pressures or rotational speeds
exceeding those specified in the data sheet or on the name plate unless the
written consent of the manufacturer has been obtained.
DANGER
Formation of a potentially explosive atmosphere inside the pump
Explosion hazard!
▷
When draining tanks take suitable measures to prevent dry running of the
pump (e.g. fill level monitoring).
6.2.1 Ambient temperature
CAUTION
Operation outside the permissible ambient temperature
Damage to the pump (set)!
▷
Observe the specified limits for permissible ambient temperatures.
Observe the following parameters and values during operation:
Table 12:
Permissible ambient temperatures
Permissible ambient temperature
Value
Maximum
40 °C
Minimum
See data sheet.
6)
Make sure the circulation line diameter is ≥ ¼".
7)
Depending on quench liquid used.