5.4.1 Connecting the motor
NOTE
In compliance with DIN VDE 0530 - Part 8, three-phase motors are always wired for
clockwise rotation (looking at the motor shaft stub).
The pump's direction of rotation is indicated by an arrow on the pump.
1. Change the motor's direction of rotation to match that of the pump.
2. Observe the manufacturer's product literature supplied with the motor.
5.5
Checking the direction of rotation
CAUTION
Motor and pump running in the wrong direction of rotation
Specified performance data are not achieved!
▷
Refer to the arrow indicating the direction of rotation on the pump.
▷
Check the direction of rotation. If required, interchange any two phases to
correct the direction of rotation.
The direction of rotation must match that of the arrow indicating the direction of
rotation on the fan hood.
1. Start the pump set and stop it again immediately to determine the motor's
direction of rotation.
2. Check the direction of rotation
The motor's direction of rotation must match the arrow indicating the direction
of rotation on the pump.
3. If the motor runs in the wrong direction of rotation, check the electrical
connection of the motor and the control system, if applicable.
5 Installation at Site
Trialine / Trialine Z
17 of 36