background image

1

   

Supplementary Operating Manual

1.1

   

General

This supplementary operating manual accompanies the operating/installation
manual. All information contained in the operating/installation manual must be
observed.

Table 1:  Relevant operating manuals

Type series

Reference numbers of the operating/installation
manuals

RPHb

1316.8012, 1316.8013

1.2

   

Uncooled pump

1.2.1   Fitting the oil mist lubrication system

1. Unscrew plugs 916.N3 and 916.N4 from the bearing brackets.
2. Screw in the pipe unions NPT 1/4" (for oil mist inlet) and NPT 1/2" (for oil mist

outlet) and connect the oil mist pipework.

3. Apply oil mist quantities as stipulated by the manufacturers of the oil mist

lubrication units used.

1.2.2   Removing the oil mist lubrication system (conversion to oil-lubricated bearings)

1. Remove screw plugs 916.N2 and flat steel elements 99-6.N1.
2. Unscrew and remove the oil mist inlet and outlet lines from the respective

connections and close the connections with plugs 916.N3/.N4.

3. Open bearing covers 361.01/360.02 and place oil rings 644.01/.02 into the bearing

brackets.

4. Fit bearing covers 361.01/360.02 again.
5. Fit vent plugs 916.N1, constant-level oilers 638.01/.03 and protective cages

169-10.01/.03 on the bearing brackets.

1.3

   

Cooled pump

1.3.1   Fitting the oil mist lubrication system

1. Unscrew plugs 916.N3 and 916.N4 from the bearing brackets.
2. Screw in pipe unions NPT 1/4" (for oil mist inlet) and NPT 1/2" (for oil mist outlet)

and connect the oil mist pipework.

3. Run suitable flexible tubing from the oil sump overflows at the constant-level

oilers into the oil return lines.

1.3.2   Removing the oil mist lubrication system (conversion to oil-lubricated bearings)

1. Unscrew and remove the oil mist inlet and outlet lines from the respective

connections at the bearing brackets and close the connections with plugs
NPT 1/4”/NPT 1/2” (916.N3/913.03).

2. Remove the flexible tubing from the oil sump overflows of the constant-level

oilers.

3. Fit protective cages 169-10.01/.03 on the bearing brackets.

 

 

 

 

 
 

 
 

 

 
 

 
 

1 Supplementary Operating Manual

4 of 6

Oil Mist Lubrication

Содержание RPHb

Страница 1: ...Oil Mist Lubrication RPHb Supplementary Operating Manual ...

Страница 2: ...ghts reserved Contents provided herein must neither be distributed copied reproduced edited or processed for any other purpose nor otherwise transmitted published or made available to a third party without KSB s express written consent Subject to technical modification without prior notice KSB Aktiengesellschaft Frankenthal 04 05 2012 ...

Страница 3: ...Contents 1 Supplementary Operating Manual 4 1 1 General 4 1 2 Uncooled pump 4 1 3 Cooled pump 4 1 4 General assembly drawing 5 Contents Oil Mist Lubrication 3 of 6 ...

Страница 4: ...and close the connections with plugs 916 N3 N4 3 Open bearing covers 361 01 360 02 and place oil rings 644 01 02 into the bearing brackets 4 Fit bearing covers 361 01 360 02 again 5 Fit vent plugs 916 N1 constant level oilers 638 01 03 and protective cages 169 10 01 03 on the bearing brackets 1 3 Cooled pump 1 3 1 Fitting the oil mist lubrication system 1 Unscrew plugs 916 N3 and 916 N4 from the b...

Страница 5: ...2 List of components Part No Description 69 10 03 Protective housing 99 6 N1 Semi finished product flat steel 361 01 02 Bearing end cover 411 70 Joint ring 642 03 Oil level sight glass 916 N1 N2 N3 Plug 1 Supplementary Operating Manual Oil Mist Lubrication 5 of 6 ...

Страница 6: ...KSB Aktiengesellschaft 67225 Frankenthal Johann Klein Str 9 67227 Frankenthal Germany Tel 49 6233 86 0 Fax 49 6233 86 3401 www ksb com 1316 812 04 EN ...

Отзывы: